8 A Fuses 567

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0458008.DR

Littelfuse

Electric Fuse

Surface Mount

32 V

63 V

8 A

Wraparound

13.448 J

-55 °C (-67 °F)

Gold

50 A

5 s

9

Tape And Reel

0.125 in (3.175 mm)

0.062 in (1.575 mm)

e4

63 V

Nano

0.125 x 0.062 x 0.062 in (3.175 x 1.575 x 1.575 mm)

0.062 in (1.575 mm)

CUL; UL

125 °C (257 °F)

172200.8

Siba

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

230 J

1.5 kA

Bulk

0.205 in (5.2 mm)

250 V

5 ms

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

DIN 41571-2

Medium Time Lag

SBS8

Mersen S A

Electric Fuse

Inline/Holder

600 V

8 A

End Cap

100 kA

0.394 in (10 mm)

600 V

0.394 x 1.378 in (10 x 35 mm)

1.378 in (35 mm)

CSA; UL

Fast

FRN-R-8

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

8 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.56 in (14.22 mm)

RK5

250 V

0.563 x 2 in (14.3 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

Time Delay

CB61F8A-TR2

Eaton Corporation

Electric Fuse

Surface Mount

125 V

125 V

8 A

Wraparound

19.5 J

-55 °C (-67 °F)

Silver Over Nickel

100 A

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current, Rated Breaking Capacity at 125 VDC: 300 A

19.5

Tape And Reel, 13 inch

0.24 in (6.1 mm)

0.101 in (2.57 mm)

e4

125 V

2410

0.24 x 0.101 x 0.101 in (6.1 x 2.57 x 2.57 mm)

0.101 in (2.57 mm)

CQC; CUL; PSE; UL

125 °C (257 °F)

Fast

0234008.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

80.675 J

-55 °C (-67 °F)

Nickel

200 A

400 ms

80.675

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

Medium

0215008.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

8 A

End Cap

209.88 J

-55 °C (-67 °F)

Matte Tin

1.5 kA

10 ms

Pre Arcing Time: Open within 10 ms at 1000% Rated Current

209.88

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0215008MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

250 V

8 A

End Cap

209.88 J

-55 °C (-67 °F)

Matte Tin

1.5 kA

10 ms

Pre Arcing Time: Open within 10 ms at 1000% Rated Current

209.88

Bulk

0.205 in (5.2 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0451008.MRL

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

8 A

Wraparound

20.23 J

-55 °C (-67 °F)

Gold

50 A

5 s

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

125 V

Nano

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

CE; CSA; CUL; PSE; TUV; UL

125 °C (257 °F)

Very Fast

AJT8

Mersen S A

Electric Fuse

Inline/Holder

600 V

500 V

8 A

End Cap

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

0.827 in (21 mm)

Indicator

0.827 x 2.244 in (21 x 57 mm)

2.244 in (57 mm)

Time Delay

0440008.WR

Littelfuse

Electric Fuse

Surface Mount

32 V

32 V

8 A

Wraparound

12.95 J

-55 °C (-67 °F)

Tin Over Nickel

50 A

4 h

0.065

Tape And Reel

0.126 in (3.2 mm)

0.064 in (1.63 mm)

e3

32 V

1206

0.126 x 0.064 x 0.032 in (3.2 x 1.63 x 0.82 mm)

0.032 in (0.82 mm)

CSA; UL

150 °C (302 °F)

CB61F8A-TR1

Eaton Corporation

Electric Fuse

Surface Mount

125 V

125 V

8 A

Wraparound

19.5 J

-55 °C (-67 °F)

Silver with Nickel barrier

100 A

5 s

Pre Arcing Time: Open within 5 s at 200% Rated Current, Rated Breaking Capacity at 125 VDC: 300 A

19.5

Tape And Reel, 7 inch

0.24 in (6.1 mm)

0.101 in (2.57 mm)

e4

125 V

2410

0.24 x 0.101 x 0.101 in (6.1 x 2.57 x 2.57 mm)

0.101 in (2.57 mm)

CQC; CUL; PSE; UL

125 °C (257 °F)

Fast

1206SFS800F/24-2

TE Connectivity

Electric Fuse

Surface Mount

24 V

8 A

Wraparound

16.9 J

-55 °C (-67 °F)

60 A

4 h

Tape And Reel

0.126 in (3.2 mm)

0.063 in (1.6 mm)

1206

0.126 x 0.063 x 0.038 in (3.2 x 1.6 x 0.97 mm)

0.038 in (0.97 mm)

UL

125 °C (257 °F)

Slow

3405.0175.24

Schurter Ag

Electric Fuse

Surface Mount

250 V

125 V

8 A

Wraparound

52.58 J

-55 °C (-67 °F)

Tin

100 A

Tape And Reel, 13 inch

0.398 in (10.1 mm)

0.118 in (3 mm)

e3

1 ms

0.118 x 0.398 in (3 x 10.1 mm)

0.398 x 0.118 x 0.148 in (10.1 x 3 x 3.75 mm)

0.118 in (3 mm)

CUL; IEC 60127-4; UL; VDE

125 °C (257 °F)

Very Fast

FRN-R-8ID

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

8 A

End Cap

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

Box

0.56 in (14.22 mm)

RK5

250 V

Indicator

0.56 x 2 in (14.22 x 50.8 mm)

2 in (50.8 mm)

CE; CSA; UL

Time Delay

AGC8

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

8 A

End Cap

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

AGC-8

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

152 mJ

Nickel

200 A

0.152

0.25 in (6.35 mm)

250 V

0.248 x 1.26 in (6.3 x 32 mm)

0.248 x 1.26 in (6.3 x 32 mm)

1.25 in (31.75 mm)

CSA; UL

Fast

BK-MDL-8-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

47.8 J

Nickel

200 A

Box

0.25 in (6.35 mm)

250 V

0.252 x 1.248 in (6.4 x 31.7 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; UL

Time Delay

BK/MDL-8-R

Cooper Electronic Technologies

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

47.8 J

200 A

MDL

Box

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA; UL

Time Delay

0507008.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

650 V

8 A

Pin Wire

53 J

-55 °C (-67 °F)

150 A

2 m

Bulk

0.275 in (6.99 mm)

3AB

1.288 in (32.72 mm)

CE; CUL; UL

125 °C (257 °F)

0FLM008T

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

8 A

End Cap

10 kA

12 s

Pre Arcing Time: Open within 12 s at 200% Rated Current

Bulk

0.406 in (10.31 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

CE; CSA; QPL; UL

Time Delay

T-8

Eaton Corporation

Electric Fuse

Inline/Holder

125 V

8 A

10 kA

Box

CE; CSA; UL

Time Delay

0217008.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

198.16 J

-55 °C (-67 °F)

Nickel

80 A

10 ms

198.16

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; KC; PSE; VDE; UL

125 °C (257 °F)

Very Fast

0217008.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

198.16 J

-55 °C (-67 °F)

Nickel

80 A

10 ms

Bulk

0.205 in (5.2 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; IEC; KC; PSE; VDE; UL

125 °C (257 °F)

Very Fast

189140.8

Siba

Electric Fuse

Inline/Holder

500 V

400 V

8 A

End Cap

370 J

Nickel

1.5 kA

Bulk

0.25 in (6.35 mm)

500 V

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.252 in (31.8 mm)

UL

Time Lag

5014006.8

Siba

Electric Fuse

Inline/Holder

690 V

8 A

End Cap

4 J

200 kA

Bulk

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

2.283 in (58 mm)

DIN, EN, IEC, UL, VDE

Very Fast

0313008.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

445 J

-55 °C (-67 °F)

Nickel

200 A

4 h

445

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Time Lag

0313008.MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

701 J

-60 °C (-76 °F)

Nickel

200 A

5 s

445

Bulk

0.25 in (6.35 mm)

Supplemental

250 V

3AG

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

ATQ8

Mersen S A

Electric Fuse

Inline/Holder

500 V

8 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

CB61F8A-TR

Cooper Industries

Electric Fuse

Surface Mount

125 V

125 V

8 A

Wraparound

19.5 J

100 A

CB61F

Rated Breaking Capacity at 125 VDC: 300 A

Tape And Reel

0.24 in (6.1 mm)

0.101 in (2.57 mm)

0.24 x 0.101 x 0.101 in (6.1 x 2.57 x 2.57 mm)

0.101 in (2.57 mm)

CQC; PSE; UL

Fast

0514008.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

500 V

8 A

Pin Wire

28.8 J

-55 °C (-67 °F)

5 kA

2 m

Bulk

0.275 in (6.985 mm)

3AB

1.288 in (32.72 mm)

125 °C (257 °F)

Fast

37418000000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

8 A

Pin Wire

220.8 J

-40 °C (-40 °F)

Tin

50 A

1 m

Ammo Pack

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

UL

85 °C (185 °F)

Time Lag

5ST8-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

260 J

-55 °C (-67 °F)

Nickel

35 A

Bulk; Tape And Reel

0.201 in (5.1 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.201 x 0.787 in (5.1 x 20 mm)

0.787 in (20 mm)

CE; CSA; UL

125 °C (257 °F)

Time Lag

FNQ-8

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

500 V

8 A

End Cap

Nickel

10 kA

Bulk

0.41 in (10.41 mm)

CC

500 V

Midget

0.41 x 1.5 in (10.41 x 38.1 mm)

1.5 in (38.1 mm)

CE, CSA, UL

Time Delay

0315008.MXP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

8 A

Pin Wire

701 J

-60 °C (-76 °F)

Matte Tin

200 A

5 s

Bulk

0.275 in (6.99 mm)

e3

3AG

0.275 x 1.274 in (6.99 x 32.36 mm)

1.288 in (32.72 mm)

CE; CSA; KC; PSE; UL

125 °C (257 °F)

Time Lag

37418000410

Littelfuse

Electric Fuse

Through Hole Mount

250 V

8 A

Pin Wire

220.8 J

-40 °C (-40 °F)

Tin

50 A

1 m

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

UL

85 °C (185 °F)

Time Lag

ATQR8

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

8 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA, CE, UL

80 °C (176 °F)

Time Delay

SF-1206HI800M-2

Bourns

Electric Fuse

Surface Mount

24 V

8 A

Wraparound

60.6 J

-55 °C (-67 °F)

80 A

200 µs

Tape And Reel, 7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

1206

0.126 x 0.063 x 0.038 in (3.2 x 1.6 x 0.97 mm)

0.038 in (0.97 mm)

UL

125 °C (257 °F)

Fast

0218008.HXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

8 A

End Cap

341.5 J

-55 °C (-67 °F)

Nickel

80 A

341.5

Bulk

0.205 in (5.2 mm)

Supplemental

250 V

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; IEC; KC; PSE; UL; VDE

125 °C (257 °F)

Time Lag

0477008.MXP

Littelfuse

Electric Fuse

Inline/Holder

500 V

400 V

8 A

End Cap

203.52 J

-55 °C (-67 °F)

Nickel

100 A

10 ms

Rated Breaking Capacity at 400 VDC: 500 A

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; PSE; UL

125 °C (257 °F)

Time Lag

0453008MR

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

8 A

Wraparound

20.23 J

-55 °C (-67 °F)

Silver

50 A

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

125 V

Nano

0.106 in (2.69 mm)

CSA; CUL; PSE; UL

125 °C (257 °F)

Very Fast

0453008.MR

Littelfuse

Electric Fuse

Surface Mount

125 V

125 V

8 A

Wraparound

20.23 J

-55 °C (-67 °F)

Silver

50 A

5 s

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

125 V

Nano

0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm)

0.106 in (2.69 mm)

CE; CSA; CUL; PSE; TUV; UL

125 °C (257 °F)

Very Fast

0469008.WR

Littelfuse

Electric Fuse

Surface Mount

24 V

8 A

Wraparound

23.72 J

-55 °C (-67 °F)

60 A

2 ms

0.23

Tape And Reel

0.129 in (3.27 mm)

0.064 in (1.63 mm)

24 V

17 mΩ

1206

0.129 x 0.064 x 0.035 in (3.27 x 1.63 x 0.9 mm)

0.035 in (0.9 mm)

CSA; CUL; UL

150 °C (302 °F)

Slow

SPXV008.T

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

8 A

End Cap

121 J

30 kA

4 m

Bulk

0.406 in (10.31 mm)

GPV

1.5 KV

0.394 x 3.346 in (10 x 85 mm)

0.409 x 3.358 in (10.4 x 85.3 mm)

3.333 in (84.65 mm)

CUL; TUV; UL

Fast

BK/MDA-8-R

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

125 V

8 A

End Cap

1.038 kJ

Nickel

200 A

2 m

Rated Breaking Capacity at 125 VDC: 10000 A

Box

0.25 in (6.35 mm)

250 V

3AB

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CSA, UL

Time Delay

SF-1206S800W-2

Bourns

Electric Fuse

Surface Mount

32 V

8 A

Wraparound

13.64 J

-55 °C (-67 °F)

Tin Over Nickel

50 A

5 s

Tape And Reel, 7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

e3

1206

0.126 x 0.063 x 0.043 in (3.2 x 1.6 x 1.08 mm)

0.043 in (1.08 mm)

TUV; UL

125 °C (257 °F)

Slow

0407008.WR

Littelfuse

Electric Fuse

Surface Mount

24 V

24 V

8 A

Wraparound

24.12 J

-55 °C (-67 °F)

Matte Tin Over Nickel

60 A

2 ms

Tape And Reel

0.126 in (3.2 mm)

0.064 in (1.63 mm)

e3

24 V

9 mΩ

1206

0.033 in (0.835 mm)

UL

150 °C (302 °F)

Time Lag

0437008.WRA

Littelfuse

Electric Fuse

Surface Mount

32 V

35 V

8 A

Wraparound

7.23 J

-55 °C (-67 °F)

50 A

1 s

Tape And Reel

0.126 in (3.2 mm)

0.064 in (1.63 mm)

1206

0.033 in (0.835 mm)

AEC-Q200; CSA; CUL; UL

150 °C (302 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.