800 A Fuses 119

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

KLH800

Littelfuse

Electric Fuse

Inline/Holder

500 V

450 V

800 A

Tab/Blade

200 kA

KLH

Rated Breaking Capacity at 450 VDC: 20000 A

2.5 in (63.5 mm)

2.5 x 2.22 in (63.5 x 56.4 mm)

2.22 in (56.4 mm)

CSA; UL

Fast

PSR032UL0800X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

800 A

Tab/Blade

60.125 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

PSR031UL0800Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

800 A

Tab/Blade

137.208 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.028 in (51.5 mm)

1.937 in (49.2 mm)

Indicator

3.402 in (86.4 mm)

CUL; UL

125 °C (257 °F)

Fast

LA30QS800-4

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

800 A

Tab/Blade

330 J

200 kA

LA30

Rated Breaking Capacity at 300 VDC: 20000 A

UL

Very Fast

LA070URD32TTI0800

Littelfuse

Electric Fuse

Inline/Holder

700 V

800 A

End Cap

115 J

200 kA

2.374 in (60.3 mm)

2.374 in (60.3 mm)

Indicator

2.374 x 2.374 x 1.929 in (60.3 x 60.3 x 49 mm)

1.929 in (49 mm)

UL

Very Fast

LDC800

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

800 A

Tab/Blade

200 kA

16 ms

Rated Breaking Capacity at 600 VDC: 50000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CE, CSA, UL

Fast

PSR032US0800X

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

800 A

Tab/Blade

60.125 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.362 in (60 mm)

1.937 in (49.2 mm)

Indicator

3.736 in (94.9 mm)

CUL; UL

125 °C (257 °F)

Fast

LA070URD33KI0800

Littelfuse

Electric Fuse

Inline/Holder

700 V

800 A

Tab/Blade

95 J

200 kA

2.933 in (74.5 mm)

2.933 in (74.5 mm)

Indicator

2.933 x 2.933 x 1.874 in (74.5 x 74.5 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

KLPC0800

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

800 A

Tab/Blade

200 kA

Rated Breaking Capacity at 480 VDC: 20000 A

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

LA070URD31LI0800

Littelfuse

Electric Fuse

Inline/Holder

700 V

800 A

Tab/Blade

140 J

200 kA

2.008 in (51 mm)

2.008 in (51 mm)

Indicator

2.008 x 2.008 x 1.874 in (51 x 51 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

L13S800

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

800 A

Tab/Blade

100 kA

L13S

Rated Breaking Capacity at 100 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

CSA; UL

Fast

KLLU800.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

800 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

2.5 in (63.5 mm)

3.752 in (95.3 mm)

CE; CSA; UL

Time Delay

KLLU800

Littelfuse

Electric Fuse

Inline/Holder

600 V

800 A

Tab/Blade

200 kA

2.5 in (63.5 mm)

L

600 V

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

JLLS800.XXP

Littelfuse

Electric Fuse

Inline/Holder

600 V

300 V

800 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Bulk

2.5 in (63.5 mm)

600 V

1.858 in (47.2 mm)

CE; CSA; UL

Fast

LA15QS800-4

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

800 A

Tab/Blade

290 J

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

1.5 in (38.1 mm)

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

UL

Very Fast

KLPC800.X

Littelfuse

Electric Fuse

Inline/Holder

600 V

480 V

800 A

Tab/Blade

200 kA

Rated Breaking Capacity at 480 VDC: 20000 A

2.5 in (63.5 mm)

L

600 V

8.626 x 3.752 in (219.1 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

581800

Littelfuse

Electric Fuse

Inline/Holder

48 V

48 V

800 A

Tab/Blade

2.5 kA

1.535 in (39 mm)

1.195 in (30.35 mm)

1.535 x 1.195 x 0.683 in (39 x 30.35 x 17.35 mm)

0.683 in (17.35 mm)

UL

L15S800

Littelfuse

Electric Fuse

Inline/Holder

150 V

100 V

800 A

Tab/Blade

-55 °C (-67 °F)

100 kA

Rated Breaking Capacity at 100 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

CSA; UL

125 °C (257 °F)

Very Fast

LA070URD33TTI0800

Littelfuse

Electric Fuse

Inline/Holder

700 V

800 A

End Cap

95 J

200 kA

2.933 in (74.5 mm)

2.933 in (74.5 mm)

Indicator

2.933 x 2.933 x 1.929 in (74.5 x 74.5 x 49 mm)

1.929 in (49 mm)

UL

Very Fast

LDC0800

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

800 A

Tab/Blade

200 kA

Rated Breaking Capacity at 600 VDC: 50000

2.5 in (63.5 mm)

2.5 x 3.752 in (63.5 x 95.3 mm)

3.752 in (95.3 mm)

CSA; UL

Time Delay

LA070URD32LI0800

Littelfuse

Electric Fuse

Inline/Holder

700 V

800 A

Tab/Blade

115 J

200 kA

2.362 in (60 mm)

2.362 in (60 mm)

Indicator

2.362 x 2.362 x 1.874 in (60 x 60 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

JLLN800

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

800 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

2.063 in (52.4 mm)

2.063 x 0.874 in (52.4 x 22.2 mm)

3.374 in (85.7 mm)

CSE; CUL; UL

Fast

PSR033FS0800Z

Littelfuse

Electric Fuse

Inline/Holder

700 V

600 V

800 A

Threaded

84.691 kJ

-55 °C (-67 °F)

200 kA

Rated Breaking Capacity at 600 VDC: 150000 A

Bulk

2.894 in (73.5 mm)

2.008 in (51 mm)

Indicator

4.268 in (108.4 mm)

CUL; UL

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.