Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
900 A |
Tab/Blade |
125 kJ |
200 kA |
Rated Breaking Capacity at 700 VDC: 200000 A |
Box |
2.402 in (61 mm) |
1.969 in (50 mm) |
2.402 x 1.969 x 2.402 in (61 x 50 x 61 mm) |
2.402 in (61 mm) |
CE; IEC; UL |
|||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
900 A |
Tab/Blade |
100 kJ |
200 kA |
Box |
2.008 in (51 mm) |
2.992 in (76 mm) |
Indicator |
2.008 x 2.992 x 2.992 in (51 x 76 x 76 mm) |
2.992 in (76 mm) |
CE; DIN 43653; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
900 A |
Tab/Blade |
100 kJ |
200 kA |
Box |
2.992 in (76 mm) |
2.992 in (76 mm) |
Indicator |
2.992 x 2.992 x 2.008 in (76 x 76 x 51 mm) |
2.008 in (51 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
900 A |
Tab/Blade |
100 kJ |
200 kA |
Rated Breaking Capacity at 700 VDC: 200000 A |
Box |
2.992 in (76 mm) |
2.008 in (51 mm) |
2.992 x 2.008 x 2.992 in (76 x 51 x 76 mm) |
2.992 in (76 mm) |
CE; IEC; UL |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
900 A |
Threaded |
107.785 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.362 in (60 mm) |
2.008 in (51 mm) |
Indicator |
3.736 in (94.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
900 A |
Tab/Blade |
100 kJ |
200 kA |
Box |
2.992 in (76 mm) |
2.992 in (76 mm) |
Indicator |
2.992 x 2.992 x 2.008 in (76 x 76 x 51 mm) |
2.008 in (51 mm) |
CE; IEC; UL |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
900 A |
Tab/Blade |
100 kJ |
200 kA |
Rated Breaking Capacity at 700 VDC: 200000 A |
Box |
2.992 in (76 mm) |
2.008 in (51 mm) |
Indicator |
2.992 x 2.008 x 2.992 in (76 x 51 x 76 mm) |
2.992 in (76 mm) |
CE; IEC; UL |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
1.3 KV |
1.3 KV |
900 A |
Tab/Blade |
305 kJ |
100 kA |
Rated Breaking Capacity at 1300 VDC: 100000 A |
Box |
6.26 in (159 mm) |
2.992 in (76 mm) |
Indicator |
6.26 x 2.992 x 2.992 in (159 x 76 x 76 mm) |
2.992 in (76 mm) |
CE; IEC; UL |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
900 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
2.63 in (66.8 mm) |
2.63 x 2.299 in (66.8 x 58.4 mm) |
2.299 in (58.4 mm) |
UL |
Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1.1 KV |
900 A |
Tab/Blade |
250 J |
100 kA |
2.933 in (74.5 mm) |
2.933 in (74.5 mm) |
Indicator |
2.933 x 2.933 x 2.854 in (74.5 x 74.5 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
900 A |
End Cap |
135 J |
200 kA |
2.933 in (74.5 mm) |
2.933 in (74.5 mm) |
Indicator |
2.933 x 2.933 x 1.929 in (74.5 x 74.5 x 49 mm) |
1.929 in (49 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
900 A |
Tab/Blade |
107.785 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.362 in (60 mm) |
1.937 in (49.2 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
900 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
2.626 in (66.7 mm) |
600 V |
2.303 in (58.5 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
900 A |
Threaded |
403.262 kJ |
-55 °C (-67 °F) |
250 kA |
Bulk |
5.043 in (128.1 mm) |
2.894 in (73.5 mm) |
Indicator |
2.894 in (73.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
900 A |
Threaded |
107.785 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.362 in (60 mm) |
2.008 in (51 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
480 V |
900 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 480 VDC: 20000 A |
2.5 in (63.5 mm) |
2.5 x 3.752 in (63.5 x 95.3 mm) |
3.752 in (95.3 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
480 V |
900 A |
Tab/Blade |
200 kA |
10.752 in (273.1 mm) |
L |
600 V |
10.752 x 3.752 in (273.1 x 95.3 mm) |
3.752 in (95.3 mm) |
CE; CSA; UL |
Time Lag |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
900 A |
End Cap |
170 J |
200 kA |
2.374 in (60.3 mm) |
2.374 in (60.3 mm) |
Indicator |
2.374 x 2.374 x 1.929 in (60.3 x 60.3 x 49 mm) |
1.929 in (49 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
900 A |
Threaded |
122.619 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.894 in (73.5 mm) |
2.008 in (51 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
900 A |
Tab/Blade |
500 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
3 in (76.2 mm) |
500 V |
3 x 3.22 in (76.2 x 81.8 mm) |
3.22 in (81.8 mm) |
CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
900 A |
Tab/Blade |
122.619 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.894 in (73.5 mm) |
1.976 in (50.2 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
650 V |
900 A |
200 kA |
LA70P |
Rated Breaking Capacity at 650 VDC: 20000 A |
CSA; UL |
Fast |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
900 A |
Threaded |
122.619 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.008 in (51 mm) |
2.894 in (73.5 mm) |
Indicator |
3.13 in (79.5 mm) |
CCC; CE; CUL; UL; IEC |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
900 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 600 VDC: 50000 |
2.5 in (63.5 mm) |
2.5 x 3.752 in (63.5 x 95.3 mm) |
3.752 in (95.3 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
900 A |
Tab/Blade |
200 kA |
16 ms |
Rated Breaking Capacity at 600 VDC: 50000 A |
2.5 in (63.5 mm) |
L |
600 V |
2.5 x 3.752 in (63.5 x 95.3 mm) |
3.752 in (95.3 mm) |
CE, CSA, UL |
Fast |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
900 A |
Tab/Blade |
403.262 kJ |
-55 °C (-67 °F) |
250 kA |
Bulk |
5.067 in (128.7 mm) |
2.894 in (73.5 mm) |
Indicator |
2.894 in (73.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
550 V |
900 A |
Threaded |
155.163 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 550 VDC: 150000 A |
Bulk |
2.028 in (51.5 mm) |
1.969 in (50 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
900 A |
Tab/Blade |
L17T |
Rated Breaking Capacity at 170 VDC: 100000 A |
CSA; UL |
|||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
900 A |
Tab/Blade |
135 J |
200 kA |
2.933 in (74.5 mm) |
2.933 in (74.5 mm) |
Indicator |
2.933 x 2.933 x 1.874 in (74.5 x 74.5 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
900 A |
Tab/Blade |
170 J |
200 kA |
2.362 in (60 mm) |
2.362 in (60 mm) |
Indicator |
2.362 x 2.362 x 1.874 in (60 x 60 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
450 V |
900 A |
200 kA |
LA50P |
Rated Breaking Capacity at 450 VDC: 20000 A |
CSA; UL |
Fast |
|||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
480 V |
900 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 480 VDC: 20000 A |
2.5 in (63.5 mm) |
2.5 x 3.752 in (63.5 x 95.3 mm) |
3.752 in (95.3 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
550 V |
900 A |
Tab/Blade |
155.163 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 550 VDC: 150000 A |
Bulk |
2.028 in (51.5 mm) |
1.937 in (49.2 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
550 V |
900 A |
Tab/Blade |
155.163 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 550 VDC: 150000 A |
Bulk |
2.028 in (51.5 mm) |
1.937 in (49.2 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
550 V |
900 A |
Threaded |
155.163 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 550 VDC: 150000 A |
Bulk |
2.028 in (51.5 mm) |
1.969 in (50 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
900 A |
Tab/Blade |
200 kA |
16 ms |
Rated Breaking Capacity at 600 VDC: 50000 A |
2.5 in (63.5 mm) |
3.752 in (95.3 mm) |
CE, CSA, UL |
Fast |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
900 A |
Tab/Blade |
200 kA |
2.5 in (63.5 mm) |
L |
600 V |
2.5 x 3.752 in (63.5 x 95.3 mm) |
3.752 in (95.3 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
900 A |
Threaded |
122.619 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.008 in (51 mm) |
2.894 in (73.5 mm) |
Indicator |
3.13 in (79.5 mm) |
CCC; CE; CUL; UL; IEC |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
900 A |
Threaded |
122.619 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.894 in (73.5 mm) |
2.008 in (51 mm) |
Indicator |
4.268 in (108.4 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
900 A |
Tab/Blade |
122.619 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.894 in (73.5 mm) |
1.976 in (50.2 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
900 A |
Tab/Blade |
403.262 kJ |
-55 °C (-67 °F) |
250 kA |
Bulk |
5.067 in (128.7 mm) |
2.894 in (73.5 mm) |
Indicator |
2.894 in (73.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
900 A |
Tab/Blade |
107.785 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.362 in (60 mm) |
1.937 in (49.2 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
900 A |
100 kA |
170 V |
1.339 in (34 mm) |
1.339 in (34 mm) |
CE, CSA, UL |
||||||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
900 A |
End Cap |
250 J |
100 kA |
2.933 in (74.5 mm) |
2.933 in (74.5 mm) |
Indicator |
2.933 x 2.933 x 2.854 in (74.5 x 74.5 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
900 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
2.626 in (66.7 mm) |
600 V |
2.303 in (58.5 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
900 A |
Tab/Blade |
170 J |
200 kA |
2.362 in (60 mm) |
2.362 in (60 mm) |
Indicator |
2.362 x 2.362 x 1.874 in (60 x 60 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
900 A |
Tab/Blade |
135 J |
200 kA |
2.933 in (74.5 mm) |
2.933 in (74.5 mm) |
Indicator |
2.933 x 2.933 x 1.874 in (74.5 x 74.5 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
900 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
2.5 in (63.5 mm) |
3.752 in (95.3 mm) |
CE; CSA; UL |
Time Delay |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.