Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
7 A |
Pin Wire |
10.4 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
30 ms |
Rated Breaking Capacity at 125 VDC: 300 A |
Ammo Pack |
0.11 in (2.8 mm) |
e3 |
Pico |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
250 mA |
Pin Wire |
11.6 mJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
1 s |
Pre Arcing Time: Open within 1 s at 200% Rated Current |
0.0116 |
Bulk |
0.11 in (2.8 mm) |
Supplemental |
e3 |
125 V |
Pico |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
30 A |
End Cap |
2.49 kJ |
-55 °C (-67 °F) |
Nickel |
100 A |
Rated Breaking Capacity at 75 VDC: 400 A |
2490 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; KC; PSE; UL |
125 °C (257 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
400 mA |
Wraparound |
41.6 mJ |
-55 °C (-67 °F) |
Gold |
50 A |
5 s |
0.04 |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e4 |
125 V |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
|||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
400 mA |
Wraparound |
41.6 mJ |
-55 °C (-67 °F) |
Gold |
50 A |
5 s |
0.04 |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e4 |
125 V |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CSA; UL |
125 °C (257 °F) |
Very Fast |
|||||||
|
Bel Fuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
12 A |
Wraparound |
38.9 J |
-55 °C (-67 °F) |
Silver |
50 A |
5 s |
Rated Breaking Capacity at 125 VDC: 300 A |
Tape And Reel, 13 inch |
0.24 in (6.1 mm) |
0.1 in (2.54 mm) |
e4 |
2410 |
0.1 in (2.54 mm) |
AEC-Q200; CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
250 V |
125 V |
2.5 A |
Wraparound |
7.5 J |
-40 °C (-40 °F) |
Gold |
200 A |
Rated Breaking Capacity at 125 VDC: 100 A |
Bag |
0.445 in (11.3 mm) |
0.165 in (4.2 mm) |
e4 |
10 ms |
0.165 x 0.437 in (4.2 x 11.1 mm) |
0.421 x 0.142 x 0.157 in (10.7 x 3.6 x 4 mm) |
0.157 in (4 mm) |
CUL; UL; VDE |
85 °C (185 °F) |
Time Lag |
||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1 A |
Wraparound |
35 mJ |
-55 °C (-67 °F) |
Tin |
50 A |
Rated Breaking Capacity at 125 VDC: 300 A |
Tape |
0.126 in (3.2 mm) |
0.061 in (1.55 mm) |
e3 |
5 s |
1206 |
0.126 x 0.061 x 0.061 in (3.2 x 1.55 x 1.55 mm) |
0.061 in (1.55 mm) |
CUL; UL |
150 °C (302 °F) |
Super Fast |
||||||||
|
Schurter Ag |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
2 A |
Pin Wire |
1.1 J |
-55 °C (-67 °F) |
Tin |
50 A |
Bulk |
0.091 in (2.3 mm) |
e3 |
4 ms |
0.091 x 0.315 in (2.3 x 8 mm) |
0.093 x 0.315 in (2.36 x 8 mm) |
0.315 in (8 mm) |
CSA; GAMT1; UL |
85 °C (185 °F) |
Very Fast |
||||||||||
|
Eaton Corporation |
Electric Fuse |
Surface Mount |
250 V |
125 V |
1.5 A |
End Cap |
1.46 J |
50 A |
Rated Breaking Capacity at 125 VDC: 50 A |
Tape And Reel |
0.405 in (10.29 mm) |
0.109 in (2.77 mm) |
250 V |
0.405 x 0.109 x 0.109 in (10.29 x 2.77 x 2.77 mm) |
0.109 in (2.77 mm) |
CSA; UL |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
3 A |
Wraparound |
20.16 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
100 ms |
Tape And Reel |
0.256 in (6.5 mm) |
0.106 in (2.69 mm) |
e3 |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
3 A |
Wraparound |
20.16 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e3 |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
2 A |
End Cap |
30 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
3 s |
Rated Breaking Capacity at 125 VDC: 10000 A |
30 |
Bulk |
0.189 in (4.8 mm) |
e3 |
250 V |
2AG |
0.177 x 0.57 in (4.5 x 14.48 mm) |
0.587 in (14.9 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
62 mA |
Pin Wire |
113 μJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
1 s |
Pre Arcing Time: Open within 1 s at 200% Rated Current |
0.0001 |
Tape And Reel |
0.11 in (2.8 mm) |
Supplemental |
e3 |
125 V |
Pico |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
8 A |
End Cap |
10 kA |
12 s |
Pre Arcing Time: Open within 12 s at 200% Rated Current |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CE; CSA; QPL; UL |
Time Delay |
|||||||||||||||
|
Siba |
Electric Fuse |
Surface Mount |
125 V |
125 V |
3.15 A |
Wraparound |
24 J |
Silver |
50 A |
Bulk |
0.24 in (6.1 mm) |
0.102 in (2.6 mm) |
e4 |
10 ms |
0.24 x 0.102 x 0.102 in (6.1 x 2.6 x 2.6 mm) |
0.102 in (2.6 mm) |
CSA; CUL; UL |
Time Lag |
||||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
63 V |
125 V |
4 A |
Wraparound |
90 mJ |
-55 °C (-67 °F) |
50 A |
Rated Breaking Capacity at 32 VDC: 300 A |
Tape |
0.126 in (3.2 mm) |
0.061 in (1.55 mm) |
63 V |
5 s |
1206 |
0.061 in (1.55 mm) |
CUL, UL |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
32 V |
125 V |
5 A |
Wraparound |
140 mJ |
-55 °C (-67 °F) |
50 A |
Rated Breaking Capacity at 32 VDC: 300 A |
Tape |
0.126 in (3.2 mm) |
0.061 in (1.55 mm) |
32 V |
5 s |
1206 |
0.061 in (1.55 mm) |
CUL, UL |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
250 V |
125 V |
160 mA |
Wraparound |
57 mJ |
-55 °C (-67 °F) |
Tin |
200 A |
Tape And Reel, 13 inch |
0.398 in (10.1 mm) |
0.118 in (3 mm) |
e3 |
10 ms |
0.118 x 0.398 in (3 x 10.1 mm) |
0.398 x 0.118 x 0.118 in (10.1 x 3 x 3 mm) |
0.118 in (3 mm) |
CUL; CQC; KTL; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1.5 A |
Wraparound |
240 mJ |
-40 °C (-40 °F) |
Tin |
100 A |
0.24 |
Tape And Reel, 7 inch |
0.291 in (7.4 mm) |
0.122 in (3.1 mm) |
e3 |
10 ms |
0.291 x 0.122 in (7.4 x 3.1 mm) |
0.291 x 0.122 x 0.102 in (7.4 x 3.1 x 2.6 mm) |
0.102 in (2.6 mm) |
CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
20 A |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
0.563 in (14.3 mm) |
2 in (50.8 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
3.5 A |
End Cap |
6.7 J |
-55 °C (-67 °F) |
Tin |
100 A |
1 s |
Rated Breaking Capacity at 125 VDC: 10000 A |
6.7 |
Bulk |
0.189 in (4.8 mm) |
e3 |
250 V |
2AG |
0.177 x 0.57 in (4.5 x 14.48 mm) |
0.587 in (14.9 mm) |
CE, CSA, PSE, UL |
125 °C (257 °F) |
Fast |
|||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 V |
2.25 A |
Pin Wire |
39 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
3 s |
Rated Breaking Capacity at 125 VDC: 10000 A |
Bulk |
0.189 in (4.8 mm) |
e3 |
2AG |
0.185 x 0.57 in (4.7 x 14.48 mm) |
0.587 in (14.9 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
62 mA |
Pin Wire |
110 μJ |
-55 °C (-67 °F) |
Tin |
50 A |
Rated Breaking Capacity at 125 VDC: 300 A |
Tape And Reel |
0.11 in (2.8 mm) |
e3 |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; QPL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
62 mA |
Pin Wire |
110 μJ |
-55 °C (-67 °F) |
Tin |
50 A |
1 s |
Rated Breaking Capacity at 125 VDC: 300 A |
Ammo Pack |
0.11 in (2.8 mm) |
e3 |
Pico |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; QPL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
62 mA |
Pin Wire |
110 μJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
1 s |
Rated Breaking Capacity at 125 VDC: 300 A |
Ammo Pack |
0.11 in (2.8 mm) |
e3 |
Pico |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; QPL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
62 mA |
Pin Wire |
113 μJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
1 s |
Pre Arcing Time: Open within 1 s at 200% Rated Current |
0.0001 |
Tape And Reel |
0.11 in (2.8 mm) |
Supplemental |
e3 |
125 V |
Pico |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
62 mA |
Pin Wire |
110 μJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
Rated Breaking Capacity at 125 VDC: 300 A |
Bulk |
0.11 in (2.8 mm) |
e3 |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; QPL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1 A |
Pin Wire |
256 mJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
4 ms |
Rated Breaking Capacity at 125 VDC: 300 A |
Ammo Pack |
0.11 in (2.8 mm) |
e3 |
Pico |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CCC; CSA; PSE; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
7 A |
Pin Wire |
10.4 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
4 ms |
Pre-Arcing Time: Open within 4 ms at 1000% Rated Current |
10.4 |
Bulk |
0.11 in (2.8 mm) |
Supplemental |
e3 |
125 V |
Pico |
0.11 x 0.28 in (2.8 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; CUL; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
100 mA |
Pin Wire |
390 μJ |
-55 °C (-67 °F) |
Tin |
10 kA |
4 h |
Bulk |
0.25 in (6.35 mm) |
e3 |
125 V |
Micro |
0.25 x 0.35 in (6.35 x 8.89 mm) |
0.35 in (8.89 mm) |
CSA; QPL; UL |
85 °C (185 °F) |
Very Fast |
|||||||||
|
Bel Fuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1.5 A |
Wraparound |
290 mJ |
-55 °C (-67 °F) |
Silver |
50 A |
5 s |
Rated Breaking Capacity at 125 VDC: 300 A |
Tape And Reel, 13 inch |
0.24 in (6.1 mm) |
0.1 in (2.54 mm) |
e4 |
2410 |
0.1 in (2.54 mm) |
AEC-Q200; CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||
|
Bel Fuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1 A |
Wraparound |
1.5 J |
-55 °C (-67 °F) |
Palladium |
50 A |
10 ms |
Rated Breaking Capacity at 125 VDC: 100 A |
Tape And Reel, 13 inch |
0.24 in (6.1 mm) |
0.1 in (2.54 mm) |
e4 |
125 V |
2410 |
0.1 in (2.54 mm) |
CUL; TUV; UL |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
20 A |
End Cap |
10 kA |
12 s |
Pre Arcing Time: Open within 12 s at 200% Rated Current |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CE; CSA; QPL; UL |
Time Delay |
|||||||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
250 V |
125 V |
500 mA |
Wraparound |
540 mJ |
-55 °C (-67 °F) |
Tin |
200 A |
Tape And Reel, 13 inch |
0.398 in (10.1 mm) |
0.118 in (3 mm) |
e3 |
10 ms |
0.118 x 0.398 in (3 x 10.1 mm) |
0.398 x 0.118 x 0.118 in (10.1 x 3 x 3 mm) |
0.118 in (3 mm) |
CUL; CQC; KTL; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1.5 A |
Wraparound |
240 mJ |
-40 °C (-40 °F) |
Tin |
100 A |
Bulk |
0.472 in (12 mm) |
0.205 in (5.2 mm) |
e3 |
10 ms |
0.472 x 0.205 in (12 x 5.2 mm) |
0.472 x 0.205 x 0.236 in (12 x 5.2 x 6 mm) |
0.236 in (6 mm) |
85 °C (185 °F) |
Very Fast |
||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1.5 A |
Wraparound |
240 mJ |
-40 °C (-40 °F) |
Tin |
100 A |
Tape And Reel, 15 inch |
0.472 in (12 mm) |
0.205 in (5.2 mm) |
e3 |
10 ms |
0.472 x 0.205 in (12 x 5.2 mm) |
0.472 x 0.205 x 0.236 in (12 x 5.2 x 6 mm) |
0.236 in (6 mm) |
85 °C (185 °F) |
Very Fast |
||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
250 V |
125 V |
2 A |
Wraparound |
3.26 J |
-55 °C (-67 °F) |
Tin |
100 A |
Bulk |
0.398 in (10.1 mm) |
0.118 in (3 mm) |
e3 |
1 ms |
0.118 x 0.398 in (3 x 10.1 mm) |
0.398 x 0.118 x 0.118 in (10.1 x 3 x 3 mm) |
0.118 in (3 mm) |
CUL; IEC 60127-4; UL; VDE |
125 °C (257 °F) |
Very Fast |
|||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1.5 A |
Wraparound |
64 mJ |
-55 °C (-67 °F) |
Tin |
50 A |
Rated Breaking Capacity at 125 VDC: 300 A |
Tape And Reel, 13 inch |
0.126 in (3.2 mm) |
0.061 in (1.55 mm) |
e3 |
5 s |
1206 |
0.126 x 0.061 x 0.061 in (3.2 x 1.55 x 1.55 mm) |
0.061 in (1.55 mm) |
CUL; UL |
150 °C (302 °F) |
Super Fast |
||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
30 A |
End Cap |
1.097 kJ |
Nickel |
1.5 kA |
2 m |
Rated Breaking Capacity at 125 VDC: 10000 A |
Box |
0.25 in (6.35 mm) |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA, UL |
Time Delay |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
30 A |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
0.563 in (14.3 mm) |
2 in (50.8 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
75 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
1.031 in (26.2 mm) |
5.874 in (149.2 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
6 A |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Box |
0.56 in (14.22 mm) |
RK5 |
250 V |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
400 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.311 in (33.3 mm) |
300 V |
2.752 in (69.9 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
400 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.311 in (33.3 mm) |
300 V |
2.752 in (69.9 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
400 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.311 in (33.3 mm) |
2.752 in (69.9 mm) |
CE; CSA; CUL; UL |
Fast |
||||||||||||||||||
|
Spc Technology/ Multicomp |
Electric Fuse |
Surface Mount |
250 V |
125 V |
1 A |
Wraparound |
870 mJ |
50 A |
Tape And Reel |
0.256 in (6.5 mm) |
0.11 in (2.8 mm) |
250 V |
2410 |
0.11 in (2.8 mm) |
UL |
Slow |
||||||||||||||
|
Spc Technology/ Multicomp |
Electric Fuse |
Surface Mount |
250 V |
125 V |
1.6 A |
Wraparound |
1.69 J |
50 A |
Tape And Reel |
0.256 in (6.5 mm) |
0.11 in (2.8 mm) |
250 V |
2410 |
0.11 in (2.8 mm) |
UL |
Slow |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.