Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
40 A |
Tab/Blade |
60 J |
200 kA |
Rated Breaking Capacity at 250 VDC: 20000 A |
Box |
0.81 in (20.57 mm) |
0.81 x 1.59 in (20.57 x 40.39 mm) |
1.59 in (40.39 mm) |
CE; CSA; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
Pin Wire |
-40 °C (-40 °F) |
Matte Tin |
Bulk |
0.374 in (9.5 mm) |
e3 |
TR5 |
0.169 in (4.3 mm) |
UL; VDE |
85 °C (185 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
Pin Wire |
-40 °C (-40 °F) |
Tin |
Bulk |
0.394 in (10 mm) |
e3 |
TR5 |
0.256 in (6.5 mm) |
UL; VDE |
85 °C (185 °F) |
||||||||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
277 V |
250 V |
500 mA |
Wraparound |
620 mJ |
-55 °C (-67 °F) |
Nickel/Tin |
1.5 kA |
Tape And Reel, 13 inch |
0.606 in (15.4 mm) |
0.211 in (5.35 mm) |
e2 |
10 ms |
0.209 x 0.63 in (5.3 x 16 mm) |
0.606 x 0.211 x 0.211 in (15.4 x 5.35 x 5.35 mm) |
0.211 in (5.35 mm) |
CUL, UL, VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
4 A |
End Cap |
200 kA |
KLB |
Rated Breaking Capacity at 250 VDC: 20000 A |
0.563 in (14.3 mm) |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
2 A |
End Cap |
1.87 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
10 ms |
Bulk |
0.205 in (5.2 mm) |
e3 |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC, CE, CSA, PSE, UL, VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
277 V |
250 V |
160 mA |
Wraparound |
55 mJ |
-55 °C (-67 °F) |
Nickel/Tin |
1.5 kA |
Tape And Reel, 13 inch |
0.606 in (15.4 mm) |
0.211 in (5.35 mm) |
e2 |
10 ms |
0.209 x 0.63 in (5.3 x 16 mm) |
0.606 x 0.211 x 0.211 in (15.4 x 5.35 x 5.35 mm) |
0.211 in (5.35 mm) |
CUL, UL, VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
35 A |
Tab/Blade |
50 J |
200 kA |
Rated Breaking Capacity at 250 VDC: 20000 A |
Box |
0.81 in (20.57 mm) |
0.81 x 1.59 in (20.57 x 40.39 mm) |
1.59 in (40.39 mm) |
CE; CSA; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
250 V |
50 mA |
Wraparound |
100 μJ |
-40 °C (-40 °F) |
Silver |
4 kA |
4 h |
Rated Breaking Capacity at 250 VDC: 4000 A |
0.0001 |
Tape And Reel |
0.119 in (3.02 mm) |
e4 |
250 V |
0.119 x 0.331 in (3.02 x 8.4 mm) |
0.331 in (8.4 mm) |
UL |
125 °C (257 °F) |
|||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
500 V |
250 V |
10 A |
End Cap |
120 kA |
Rated Breaking Capacity at 250 VDC: 100000 A |
0.402 in (10.2 mm) |
1.496 in (38 mm) |
CE |
|||||||||||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
250 V |
250 V |
2 A |
Wraparound |
1.4 J |
-55 °C (-67 °F) |
Tin |
100 A |
Bulk |
0.433 in (11 mm) |
0.181 in (4.6 mm) |
e3 |
1 ms |
0.433 x 0.181 in (11 x 4.6 mm) |
0.433 x 0.181 x 0.154 in (11 x 4.6 x 3.9 mm) |
0.154 in (3.9 mm) |
CUL; UL; VDE |
125 °C (257 °F) |
Very Fast |
|||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
2.25 A |
Pin Wire |
7.2 J |
Tin Lead |
35 A |
0.276 in (7 mm) |
e0 |
0.276 x 1.275 in (7 x 32.39 mm) |
1.275 in (32.39 mm) |
CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
20 A |
End Cap |
2.6 kJ |
-55 °C (-67 °F) |
Nickel |
400 A |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
2600 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
IEC; PSE; SEMKO; UL |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
Pin Wire |
-40 °C (-40 °F) |
Bulk |
0.374 in (9.5 mm) |
TR5 |
0.118 in (3 mm) |
UL; VDE |
85 °C (185 °F) |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
15 A |
End Cap |
245 J |
-55 °C (-67 °F) |
Nickel |
400 A |
4 h |
245 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; KC; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
1.5 A |
End Cap |
40.1 J |
-55 °C (-67 °F) |
Nickel |
100 A |
4 h |
40.1 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
315 mA |
End Cap |
975 mJ |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
5 ms |
Pre Arcing Time: Open within 5 ms at 1000% Rated Current |
0.975 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; IEC; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
3.15 A |
End Cap |
43.255 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
43.255 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
1 A |
End Cap |
180 mJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
10 ms |
Bulk |
0.205 in (5.2 mm) |
e3 |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC, CE, CSA, PSE, UL, VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
10 A |
End Cap |
333.565 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
333.56 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
10 A |
End Cap |
333.565 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
333.56 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||
Spc Technology/ Multicomp |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
160 mA |
Pin Wire |
133.1 mJ |
-55 °C (-67 °F) |
100 A |
0.329 in (8.35 mm) |
0.169 in (4.3 mm) |
20 ms |
0.329 x 0.169 x 0.303 in (8.35 x 4.3 x 7.7 mm) |
0.303 in (7.7 mm) |
125 °C (257 °F) |
Slow |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
1.6 A |
Pin Wire |
6.83 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
6.83 |
Bulk |
0.228 in (5.8 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.886 in (22.5 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
16 A |
Pin Wire |
1.408 kJ |
-55 °C (-67 °F) |
Matte Tin |
500 A |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
1408 |
Bulk |
0.228 in (5.8 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.886 in (22.5 mm) |
IEC; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
277 V |
250 V |
2 A |
Wraparound |
9.6 J |
-55 °C (-67 °F) |
Nickel/Tin |
1.5 kA |
Tape And Reel, 13 inch |
0.606 in (15.4 mm) |
0.211 in (5.35 mm) |
e2 |
10 ms |
0.209 x 0.63 in (5.3 x 16 mm) |
0.606 x 0.211 x 0.211 in (15.4 x 5.35 x 5.35 mm) |
0.211 in (5.35 mm) |
CUL, UL, VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
2 A |
End Cap |
11.68 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
800 mA |
End Cap |
8.2 J |
-55 °C (-67 °F) |
Nickel |
100 A |
4 h |
8.2 |
Bulk |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CE; CSA; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
250 V |
250 mA |
Wraparound |
5.79 mJ |
-40 °C (-40 °F) |
4 kA |
4 h |
Rated Breaking Capacity at 250 VDC: 4000 A |
0.0058 |
Tape And Reel |
0.119 in (3.02 mm) |
250 V |
0.119 x 0.331 in (3.02 x 8.4 mm) |
0.331 in (8.4 mm) |
UL |
125 °C (257 °F) |
|||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
500 mA |
Pin Wire |
340 mJ |
1.5 kA |
10 ms |
0.207 in (5.25 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CCC; CSA; CUL; SEMKO; SEV; PSE; VDE; UL |
Time Lag |
|||||||||||||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
250 V |
250 V |
80 mA |
Wraparound |
22 mJ |
-55 °C (-67 °F) |
Tin |
200 A |
Tape And Reel, 13 inch |
0.398 in (10.1 mm) |
0.118 in (3 mm) |
e3 |
10 ms |
0.118 x 0.398 in (3 x 10.1 mm) |
0.398 x 0.118 x 0.118 in (10.1 x 3 x 3 mm) |
0.118 in (3 mm) |
CUL; CQC; KTL; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
4 A |
End Cap |
14.995 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
10 ms |
Bulk |
0.205 in (5.2 mm) |
e3 |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC, CE, CSA, PSE, UL, VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
10 A |
Pin Wire |
333.565 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
333.56 |
Bulk |
0.228 in (5.8 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.886 in (22.5 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL |
125 °C (257 °F) |
Time Lag |
|||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
10 A |
Pin Wire |
333.565 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
333.56 |
Bulk |
0.228 in (5.8 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.886 in (22.5 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL |
125 °C (257 °F) |
Time Lag |
|||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
550 V |
250 V |
40 A |
Tab/Blade |
1.4 kJ |
Rated Breaking Capacity at 250 VDC: 1400 A |
Box |
0.827 in (21 mm) |
0.827 x 2.185 in (21 x 55.5 mm) |
2.185 in (55.5 mm) |
BS; IEC |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
3.15 A |
Pin Wire |
43.255 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
43.255 |
Bulk |
0.228 in (5.8 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.886 in (22.5 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
315 mA |
Pin Wire |
975 mJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
5 ms |
Pre Arcing Time: Open within 5 ms at 1000% Rated Current |
0.975 |
Bulk |
0.236 in (6 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.236 x 0.886 in (6 x 22.5 mm) |
0.886 in (22.5 mm) |
CE; IEC; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||
|
Schurter Ag |
Electric Fuse |
Surface Mount |
277 V |
250 V |
1 A |
Wraparound |
3.6 J |
-55 °C (-67 °F) |
Nickel/Tin |
1.5 kA |
Tape And Reel, 13 inch |
0.606 in (15.4 mm) |
0.211 in (5.35 mm) |
e2 |
10 ms |
0.209 x 0.63 in (5.3 x 16 mm) |
0.606 x 0.211 x 0.211 in (15.4 x 5.35 x 5.35 mm) |
0.211 in (5.35 mm) |
CUL, UL, VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
2.5 A |
Pin Wire |
22.29 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
22.29 |
Bulk |
0.228 in (5.8 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.886 in (22.5 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
60 A |
Tab/Blade |
140 J |
200 kA |
Rated Breaking Capacity at 250 VDC: 20000 A |
Box |
0.81 in (20.57 mm) |
0.81 x 1.59 in (20.57 x 40.39 mm) |
1.59 in (40.39 mm) |
CE; CSA; UL |
||||||||||||||||
Spc Technology/ Multicomp |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
2 A |
Pin Wire |
32 J |
-55 °C (-67 °F) |
100 A |
0.329 in (8.35 mm) |
0.169 in (4.3 mm) |
20 ms |
0.329 x 0.169 x 0.303 in (8.35 x 4.3 x 7.7 mm) |
0.303 in (7.7 mm) |
125 °C (257 °F) |
Slow |
|||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
500 V |
250 V |
50 A |
End Cap |
120 kA |
Rated Breaking Capacity at 250 VDC: 100000 A |
0.563 in (14.3 mm) |
2.008 in (51 mm) |
CE; IEC60269-1; IEC60269-2 |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
5 A |
End Cap |
27.46 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
10 ms |
Bulk |
0.205 in (5.2 mm) |
e3 |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC, CE, CSA, PSE, UL, VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
250 V |
200 mA |
Wraparound |
3.8 mJ |
-40 °C (-40 °F) |
Matte Tin Over Nickel |
4 kA |
4 h |
Rated Breaking Capacity at 250 VDC: 4000 A |
0.0037 |
Tape And Reel |
0.119 in (3.02 mm) |
e3 |
250 V |
0.119 x 0.331 in (3.02 x 8.4 mm) |
0.331 in (8.4 mm) |
UL |
125 °C (257 °F) |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
2.5 A |
End Cap |
22.29 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
22.29 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
2.5 A |
End Cap |
22.29 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
Bulk |
0.205 in (5.2 mm) |
e3 |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
250 V |
3 A |
Tab/Blade |
200 kA |
0.543 in (13.8 mm) |
0.543 x 1.398 in (13.8 x 35.5 mm) |
1.398 in (35.5 mm) |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
8 A |
End Cap |
209.88 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
209.88 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
8 A |
End Cap |
209.88 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
209.88 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.