300 V Fuses 1,812

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

FRS-R-40

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

40 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Box

1.063 in (27 mm)

1.063 x 5.5 in (27 x 139.7 mm)

5.5 in (139.7 mm)

CE; CSA; UL

Time Delay

SC-40

Eaton Corporation

Electric Fuse

Inline/Holder

480 V

300 V

40 A

End Cap

100 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Box

0.406 in (10.3 mm)

G

480 V

0.406 x 2.25 in (10.3 x 57.15 mm)

2.25 in (57.15 mm)

CSA; UL

Fast And Time Delay

TCF40

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

40 A

Tab/Blade

-40 °C (-40 °F)

Tin

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

2.126 in (54 mm)

0.984 in (25 mm)

e3

Indicator

2.13 x 1 x 1.125 in (54.1 x 25.4 x 28.58 mm)

1.142 in (29 mm)

CSA; UL

80 °C (176 °F)

Time Delay

LPJ-100SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.126 in (28.6 mm)

J

600 V

1.126 x 2.626 in (28.6 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; UL

Time Delay

LPJ-40SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

40 A

End Cap

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.063 in (27 mm)

J

600 V

1.063 x 2.374 in (27 x 60.3 mm)

2.374 in (60.3 mm)

CE; CSA; UL

Time Delay

LP-CC-30

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

30 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Box

0.394 in (10 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.496 in (38 mm)

CE; CSA; UL

Time Delay

LPJ-100SPI

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

1.126 in (28.6 mm)

J

600 V

Indicator

1.126 x 2.626 in (28.6 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; UL

Time Delay

ATDR20

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LPJ-200SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

200 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.63 in (41.4 mm)

J

600 V

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

LPJ-200SPI

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

200 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

1.63 in (41.4 mm)

J

600 V

Indicator

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

LPJ-400SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

400 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

2.11 in (53.6 mm)

J

600 V

2.11 x 1.508 in (53.6 x 38.3 mm)

1.508 in (38.3 mm)

CE; CSA; UL

Time Delay

FNQ-R-12

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

12 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Box

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

LPJ-125SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

125 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.63 in (41.4 mm)

J

600 V

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

SP/LPJ-100SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

100 A

Tab/Blade

Silver

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.126 in (28.6 mm)

e4

1.126 x 2.626 in (28.6 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; UL

Time Delay

FNQ-R-15

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

15 A

End Cap

Nickel

200 kA

Rated Breaking Capacity at 300 VDC: 10000 A

Box

0.406 in (10.3 mm)

CC

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.5 in (38.1 mm)

CE; CSA; UL

Time Delay

LP-CC-20

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Box

0.394 in (10 mm)

600 V

0.406 x 1.5 in (10.3 x 38.1 mm)

1.496 in (38 mm)

CE; CSA; UL

Time Delay

LP-CC-25

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Box

0.394 in (10 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.496 in (38 mm)

CE; CSA; UL

Time Delay

ATQR25

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA, CE, UL

80 °C (176 °F)

Time Delay

LPJ-70SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.126 in (28.6 mm)

J

600 V

1.126 x 2.626 in (28.6 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; UL

Time Delay

36913150000

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

3.15 A

Pin Wire

78.388 J

-40 °C (-40 °F)

Matte Tin

50 A

20 s

55

Ammo Pack

0.335 in (8.5 mm)

0.157 in (4 mm)

e3

300 V

TE5

0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm)

0.315 in (8 mm)

CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

ATDR15

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

15 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LPJ-125SPI

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

125 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

1.63 in (41.4 mm)

J

600 V

Indicator

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

ATDR30

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

30 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

ATDR4

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LP-CC-1

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

1 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Box

0.394 in (10 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.496 in (38 mm)

CE; CSA; UL

Time Delay

ATDR10

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

10 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LPJ-90SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

90 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.126 in (28.6 mm)

J

600 V

1.126 x 2.626 in (28.6 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; UL

Time Delay

LPJ-60SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

60 A

End Cap

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.063 in (27 mm)

J

600 V

1.063 x 2.374 in (27 x 60.3 mm)

2.374 in (60.3 mm)

CE; CSA; UL

Time Delay

LPJ-150SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

150 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

1.63 in (41.4 mm)

J

600 V

1.63 x 3 in (41.4 x 76.2 mm)

3 in (76.2 mm)

CE; CSA; UL

Time Delay

A6T500

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

500 A

Tab/Blade

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

2.063 in (52.4 mm)

2.063 x 1.701 in (52.4 x 43.2 mm)

1.701 in (43.2 mm)

CSA; UL

Fast

ATDR2-1/2

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

2.5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

A6T50

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

50 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.811 in (20.6 mm)

0.811 x 1.512 in (20.6 x 38.4 mm)

1.512 in (38.4 mm)

CSA; UL

Fast

ATQR20

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

20 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA, CE, UL

80 °C (176 °F)

Time Delay

LPJ-70SPI

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

70 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

1.126 in (28.6 mm)

J

600 V

Indicator

1.126 x 2.626 in (28.6 x 66.7 mm)

2.626 in (66.7 mm)

CE; CSA; UL

Time Delay

LPJ-10SP

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

10 A

End Cap

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.811 in (20.6 mm)

J

600 V

0.811 x 2.252 in (20.6 x 57.2 mm)

2.252 in (57.2 mm)

CE; CSA; UL

Time Delay

ATQR5

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA, CE, UL

80 °C (176 °F)

Time Delay

ATQR4

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

4 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA, CE, UL

80 °C (176 °F)

Time Delay

LP-CC-2-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

2.5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Box

0.394 in (10 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.496 in (38 mm)

CE; CSA; UL

Time Delay

ATDR25

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

ATDR2-1/4

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

2.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LP-CC-1-1/4

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

1.25 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

Box

0.394 in (10 mm)

0.406 x 1.5 in (10.3 x 38.1 mm)

1.496 in (38 mm)

CE; CSA; UL

Time Delay

ATDR2

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

2 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

ATQR4-1/2

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

4.5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA, CE, UL

80 °C (176 °F)

Time Delay

ATDR12

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

12 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

ATDR1/2

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

500 mA

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

ATDR5

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

5 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

LPJ-400SPI

Eaton Corporation

Electric Fuse

Inline/Holder

600 V

300 V

400 A

Tab/Blade

300 kA

Rated Breaking Capacity at 300 VDC: 100000 A

Box

2.11 in (53.6 mm)

J

600 V

Indicator

2.11 x 1.508 in (53.6 x 38.3 mm)

1.508 in (38.3 mm)

CE; CSA; UL

Time Delay

ATDR3

Mersen S A

Electric Fuse

Inline/Holder

600 V

300 V

3 A

End Cap

200 kA

Rated Breaking Capacity at 300 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.