32 V Fuses 2,400+

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0287005

Littelfuse

Electric Fuse

Inline/Holder

32 V

5 A

Tab/Blade

26 J

-40 °C (-40 °F)

1 kA

0.75 in (19.05 mm)

0.2 in (5.08 mm)

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

105 °C (221 °F)

0434.375NR

Littelfuse

Electric Fuse

Surface Mount

32 V

32 V

375 mA

Wraparound

5.3 mJ

-55 °C (-67 °F)

Tin/Lead with Nickel barrier

50 A

4 h

Rated Breaking Capacity at 32 VDC: 50 A

0.0053

Tape And Reel

0.063 in (1.6 mm)

0.032 in (0.81 mm)

Supplemental

e0

32 V

0603

0.063 x 0.032 x 0.012 in (1.6 x 0.81 x 0.31 mm)

0.012 in (0.31 mm)

CSA; UL

90 °C (194 °F)

Very Fast

168.6785.5152

Littelfuse

Electric Fuse

Inline/Holder

32 V

15 A

Tab/Blade

178 J

Matte Tin

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

178

Bulk

0.469 in (11.9 mm)

0.15 in (3.8 mm)

FK1

e3

32 V

Mini

0.469 x 0.15 x 0.339 in (11.9 x 3.8 x 8.6 mm)

0.339 in (8.6 mm)

UL

0298080.ZXEH-UL

Littelfuse

Electric Fuse

Inline/Holder

32 V

80 A

Tab/Blade

21.5 kJ

-40 °C (-40 °F)

2 kA

100 ms

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.39 in (9.9 mm)

ISO; UL

125 °C (257 °F)

Time Delay

0283030.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

-40 °C (-40 °F)

40 ms

1.874 in (47.6 mm)

0.593 in (15.05 mm)

32 V

0.898 x 0.638 x 0.846 in (22.8 x 16.2 x 21.5 mm)

0.846 in (21.5 mm)

125 °C (257 °F)

0257025.U

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

1.08 kJ

-40 °C (-40 °F)

Silver

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e4

0.74 in (18.8 mm)

UL

105 °C (221 °F)

0299080.ZXT

Littelfuse

Electric Fuse

Inline/Holder

32 V

80 A

Tab/Blade

43.6 kJ

-40 °C (-40 °F)

Silver

1 kA

40 ms

43600

Bulk

1.15 in (29.2 mm)

0.346 in (8.8 mm)

e4

32 V

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.6 mm)

UL

125 °C (257 °F)

Time Delay

0433003.NR

Littelfuse

Electric Fuse

Surface Mount

32 V

32 V

3 A

Wraparound

700 mJ

-55 °C (-67 °F)

Tin Lead

50 A

433

Rated Breaking Capacity at 32 VDC: 50 A

Tape And Reel

0.125 in (3.18 mm)

0.06 in (1.52 mm)

e0

0.125 x 0.06 x 0.023 in (3.18 x 1.52 x 0.58 mm)

0.023 in (0.58 mm)

CSA; UL

90 °C (194 °F)

Very Fast

0253015.NAT3

Littelfuse

Electric Fuse

Through Hole Mount

32 V

32 V

15 A

Pin Wire

68.8 J

-55 °C (-67 °F)

Tin

50 A

10 s

Rated Breaking Capacity at 125 VDC: 300 A, Pre Arcing Time: Open within 10000 ms at 200% Rated Current

Ammo Pack

0.11 in (2.8 mm)

e3

Pico

0.11 x 0.28 in (2.8 x 7.11 mm)

0.28 in (7.11 mm)

CSA; QPL; UL

125 °C (257 °F)

Very Fast

0298150ZXEH

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

100 kJ

-40 °C (-40 °F)

Silver

2 kA

Bulk

1.15 in (29.21 mm)

0.75 in (19.05 mm)

e4

1.15 x 0.75 x 0.42 in (29.21 x 19.05 x 10.67 mm)

0.42 in (10.67 mm)

125 °C (257 °F)

0251015.MXHF

Littelfuse

Electric Fuse

Through Hole Mount

32 V

32 V

15 A

Pin Wire

68.8 J

-55 °C (-67 °F)

Matte Tin

50 A

251

Rated Breaking Capacity at 32 VDC: 300 A

Bulk

0.11 in (2.8 mm)

e3

0.11 x 0.28 in (2.8 x 7.11 mm)

0.28 in (7.11 mm)

CSA; QPL; UL

125 °C (257 °F)

Very Fast

153.7000.6152

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

83.4 kJ

-40 °C (-40 °F)

2 kA

100 ms

0.63 in (16 mm)

0.472 in (12 mm)

32 V

0.315 in (8 mm)

CUL; ISO; UL

125 °C (257 °F)

299050

Littelfuse

Electric Fuse

Inline/Holder

32 V

50 A

Tab/Blade

11.3 kJ

Silver

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

1.15 in (29.21 mm)

0.348 in (8.85 mm)

e4

1.15 x 0.348 x 0.85 in (29.21 x 8.85 x 21.59 mm)

0.85 in (21.59 mm)

UL

Slow

169.6885.5302

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

6 kJ

169

Rated Breaking Capacity at 32 VDC: 1000 A

1.169 in (29.7 mm)

0.358 in (9.1 mm)

1.169 x 0.358 x 0.839 in (29.7 x 9.1 x 21.3 mm)

0.839 in (21.3 mm)

UL

AGX25

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

25 A

End Cap

0.25 in (6.35 mm)

32 V

8AG

1 in (25.4 mm)

0251012.PR

Littelfuse

Electric Fuse

Through Hole Mount

32 V

32 V

12 A

Pin Wire

45.2 J

-55 °C (-67 °F)

Tin

50 A

Rated Breaking Capacity at 125 VDC: 300 A, Pre Arcing Time: Open within 10000 ms at 200% Rated Current

Tape And Reel

0.11 in (2.8 mm)

e3

0.11 x 0.28 in (2.8 x 7.11 mm)

0.28 in (7.11 mm)

CSA; UL

125 °C (257 °F)

Very Fast

0253015

Littelfuse

Electric Fuse

Through Hole Mount

32 V

32 V

15 A

Pin Wire

68.8 J

-55 °C (-67 °F)

Pure Tin

50 A

Rated Breaking Capacity at 32 VDC: 300 A

0.095 in (2.41 mm)

0.095 x 0.28 in (2.41 x 7.11 mm)

0.28 in (7.11 mm)

CSA; PSE; QPL; UL

125 °C (257 °F)

Very Fast

MAX80BP

Littelfuse

Electric Fuse

Inline/Holder

32 V

80 A

Tab/Blade

43.6 kJ

-40 °C (-40 °F)

1 kA

40 ms

Bulk

1.15 in (29.2 mm)

0.346 in (8.8 mm)

0.85 in (21.6 mm)

UL

125 °C (257 °F)

Slow

0298200.UXP-2M8

Littelfuse

Electric Fuse

Inline/Holder

32 V

200 A

Tab/Blade

245.8 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.381 in (9.69 mm)

125 °C (257 °F)

Time Delay

AGW3CABP

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

3 A

End Cap

0.25 in (6.35 mm)

32 V

7AG

0.875 in (22.225 mm)

0407004.WRA

Littelfuse

Electric Fuse

Surface Mount

32 V

4 A

Wraparound

4.18 J

-55 °C (-67 °F)

50 A

50 ms

Tape And Reel

0.126 in (3.2 mm)

0.064 in (1.63 mm)

1206

0.033 in (0.835 mm)

AEC-Q200; CUL; UL

150 °C (302 °F)

25707.5

Littelfuse

Electric Fuse

Inline/Holder

32 V

7.5 A

Tab/Blade

60 J

Tin/Copper

1 kA

0.75 in (19.05 mm)

0.2 in (5.08 mm)

e2

32 V

0.75 x 0.2 x 0.48 in (19.05 x 5.08 x 12.19 mm)

0.48 in (12.19 mm)

CSA; UL

Fast

0298175.UX1M8

Littelfuse

Electric Fuse

Inline/Holder

32 V

175 A

Tab/Blade

168 kJ

-40 °C (-40 °F)

2 kA

100 ms

Bulk

1.15 in (29.2 mm)

0.748 in (19 mm)

32 V

Mega

0.39 in (9.9 mm)

125 °C (257 °F)

Time Delay

0501020.WRT

Littelfuse

Electric Fuse

Surface Mount

32 V

20 A

Wraparound

54.76 J

-55 °C (-67 °F)

150 A

Tape And Reel

0.126 in (3.2 mm)

0.064 in (1.63 mm)

0.126 x 0.064 x 0.02 in (3.2 x 1.63 x 0.5 mm)

0.02 in (0.5 mm)

CSA; UL

150 °C (302 °F)

Fast

CNL225

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

225 A

Tab/Blade

2.5 kA

3.181 in (80.8 mm)

2.43 in (61.72 mm)

UL

Fast

156.5677.5802

Littelfuse

Electric Fuse

Inline/Holder

32 V

80 A

Tab/Blade

44.8 kJ

-40 °C (-40 °F)

1 kA

10 ms

Bulk

1.654 in (42 mm)

0.472 in (12 mm)

1.654 x 0.472 x 0.016 in (42 x 12 x 0.4 mm)

0.031 in (0.8 mm)

125 °C (257 °F)

AGC15H/311015

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

15 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

3AG

1.25 in (31.75 mm)

Normal

153.5395.6502

Littelfuse

Electric Fuse

Inline/Holder

32 V

500 A

Tab/Blade

1.449 MJ

-40 °C (-40 °F)

1.5 kA

100 ms

1.142 in (29 mm)

0.642 in (16.3 mm)

32 V

0.394 in (10 mm)

UL

125 °C (257 °F)

Slow

036201.5M

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

1.5 A

End Cap

Bulk

0.25 in (6.35 mm)

32 V

8AG

1 in (25.4 mm)

Normal

164.6185.5102

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

110 J

Matte Tin

1 kA

Rated Breaking Capacity at 32 VDC: 1000 A

110

Bulk

0.748 in (19 mm)

0.197 in (5 mm)

ATO

e3

32 V

FKSATO

0.748 x 0.197 x 0.52 in (19 x 5 x 13.2 mm)

0.52 in (13.2 mm)

UL

0495080TXN

Littelfuse

Electric Fuse

Inline/Holder

32 V

80 A

Tab/Blade

-40 °C (-40 °F)

1 kA

495

Bulk

0.555 in (14.1 mm)

0.476 in (12.1 mm)

0.555 x 0.476 x 1.063 in (14.1 x 12.1 x 27 mm)

1.063 in (27 mm)

125 °C (257 °F)

0483010.DR

Littelfuse

Electric Fuse

Surface Mount

32 V

32 V

10 A

Wraparound

16 J

-55 °C (-67 °F)

Copper/Nickel/Tin

50 A

5 s

Pre Arcing Time: Open within 5 s at 250% Rated Current

Tape And Reel

0.13 in (3.302 mm)

0.062 in (1.575 mm)

e2

32 V

1206

0.062 in (1.5748 mm)

UL

125 °C (257 °F)

AGW1

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

1 A

End Cap

0.25 in (6.35 mm)

32 V

7AG

0.875 in (22.225 mm)

153.3512

Littelfuse

Electric Fuse

Inline/Holder

32 V

Tab/Blade

Tin

153

Rated Breaking Capacity at 32 VDC: 2000 A

Tube

1.386 in (35.2 mm)

0.64 in (16.25 mm)

e3

100 ms

1.386 x 0.64 x 0.703 in (35.2 x 16.25 x 17.85 mm)

0.703 in (17.85 mm)

RF0460-000

Littelfuse

Electric Fuse

Surface Mount

32 V

4.5 A

Wraparound

3.2 J

50 A

RF0460-000

UL

125 °C (257 °F)

498040

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

-40 °C (-40 °F)

1 kA

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

0327010.YX2S

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

90 J

-40 °C (-40 °F)

1 kA

20 ms

Bulk

0.358 in (9.1 mm)

0.15 in (3.8 mm)

32 V

Micro

0.602 in (15.3 mm)

125 °C (257 °F)

0337010.PX2S

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

89 J

-40 °C (-40 °F)

1 kA

20 ms

Bulk

0.567 in (14.4 mm)

0.165 in (4.2 mm)

32 V

Micro

0.417 in (10.6 mm)

125 °C (257 °F)

153.5631.5302

Littelfuse

Electric Fuse

Inline/Holder

32 V

30 A

Tab/Blade

5.1 kJ

-40 °C (-40 °F)

Tin

1 kA

100 ms

5100

0.63 in (16 mm)

0.472 in (12 mm)

e3

32 V

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.307 in (7.8 mm)

CUL; ISO; UL

125 °C (257 °F)

315025

Littelfuse

Electric Fuse

Through Hole Mount

32 V

32 V

25 A

Pin Wire

16.5 kJ

Tin/Lead

300 A

0.275 in (6.985 mm)

e0

0.275 x 1.275 in (6.985 x 32.385 mm)

1.275 in (32.385 mm)

CE; CSA; PSE; UL

Slow

RF0349-000

Littelfuse

Electric Fuse

Surface Mount

32 V

4.5 A

Wraparound

2.7 J

50 A

UL

125 °C (257 °F)

Slow

0253015.HXT3L

Littelfuse

Electric Fuse

Through Hole Mount

32 V

32 V

15 A

Pin Wire

68.8 J

-55 °C (-67 °F)

Pure Tin

50 A

253

Rated Breaking Capacity at 32 VDC: 300 A

Bulk

0.11 in (2.8 mm)

0.11 x 0.28 in (2.8 x 7.11 mm)

0.28 in (7.11 mm)

CSA; QPL; UL

125 °C (257 °F)

Very Fast

0253012.NAL

Littelfuse

Electric Fuse

Through Hole Mount

32 V

32 V

12 A

Pin Wire

45.2 J

-55 °C (-67 °F)

Tin

50 A

Rated Breaking Capacity at 32 VDC: 300 A

Ammo Pack

0.103 in (2.61 mm)

e3

0.103 x 0.28 in (2.61 x 7.11 mm)

0.28 in (7.11 mm)

CSA; UL

125 °C (257 °F)

Very Fast

169.6885.5701

Littelfuse

Electric Fuse

Inline/Holder

32 V

70 A

Tab/Blade

70 kJ

169

Rated Breaking Capacity at 32 VDC: 1000 A

1.169 in (29.7 mm)

0.358 in (9.1 mm)

1.169 x 0.358 x 0.839 in (29.7 x 9.1 x 21.3 mm)

0.839 in (21.3 mm)

UL

0434001

Littelfuse

Electric Fuse

Surface Mount

32 V

32 V

1 A

Wraparound

21 mJ

-55 °C (-67 °F)

Tin/Lead with Nickel barrier

50 A

434

Rated Breaking Capacity at 32 VDC: 50 A

0.063 in (1.6 mm)

0.032 in (0.81 mm)

e0

0.063 x 0.032 x 0.012 in (1.6 x 0.81 x 0.31 mm)

0.012 in (0.31 mm)

CSA; UL

90 °C (194 °F)

Very Fast

0253012.MRT3L

Littelfuse

Electric Fuse

Through Hole Mount

32 V

32 V

12 A

Pin Wire

45.2 J

-55 °C (-67 °F)

Tin Over Copper

50 A

0253

Rated Breaking Capacity at 32 VDC: 300 A

Tape And Reel

0.103 in (2.61 mm)

e3

0.103 x 0.28 in (2.61 x 7.11 mm)

0.28 in (7.11 mm)

CSA; UL

125 °C (257 °F)

Very Fast

1692400100

Littelfuse

Electric Fuse

Inline/Holder

32 V

40 A

Tab/Blade

13 kJ

-40 °C (-40 °F)

1 kA

Bulk

1.173 in (29.8 mm)

0.358 in (9.1 mm)

40 ms

0.835 in (21.2 mm)

85 °C (185 °F)

Time Lag

0298175.UXP-1M8

Littelfuse

Electric Fuse

Inline/Holder

32 V

175 A

Tab/Blade

205.5 kJ

-40 °C (-40 °F)

Tin

2 kA

100 ms

1.15 in (29.2 mm)

0.75 in (19.05 mm)

e3

32 V

Mega

0.381 in (9.69 mm)

125 °C (257 °F)

Time Delay

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.