35 V Fuses 16

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0437007.WR

Littelfuse

Electric Fuse

Surface Mount

32 V

35 V

7 A

Wraparound

5.02 J

-55 °C (-67 °F)

Tin Over Nickel

50 A

1 s

5.02

Tape And Reel

0.126 in (3.2 mm)

0.064 in (1.63 mm)

e3

35 V

1206

0.126 x 0.064 x 0.032 in (3.2 x 1.63 x 0.82 mm)

0.033 in (0.835 mm)

CSA; CUL; UL

150 °C (302 °F)

Fast

0437007.WRA

Littelfuse

Electric Fuse

Surface Mount

32 V

35 V

7 A

Wraparound

5.02 J

-55 °C (-67 °F)

Tin with Nickel barrier

50 A

1 s

Tape And Reel

0.126 in (3.2 mm)

0.064 in (1.63 mm)

e3

1206

0.126 x 0.064 x 0.033 in (3.2 x 1.63 x 0.84 mm)

0.033 in (0.835 mm)

AEC-Q200; CSA; CUL; UL

150 °C (302 °F)

Fast

SF-1206HV25M-2

Bourns

Electric Fuse

Surface Mount

35 V

Wraparound

120 J

-55 °C (-67 °F)

200 A

Tape And Reel, 7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

5 s

1206

0.126 x 0.063 x 0.038 in (3.2 x 1.6 x 0.97 mm)

0.038 in (0.97 mm)

UL

125 °C (257 °F)

SF-1206HV40M-2

Bourns

Electric Fuse

Surface Mount

35 V

Wraparound

240 J

-55 °C (-67 °F)

200 A

Tape And Reel, 7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

5 s

1206

0.126 x 0.063 x 0.051 in (3.2 x 1.6 x 1.3 mm)

0.051 in (1.3 mm)

UL

125 °C (257 °F)

SF-0402FP020F-2

Bourns

Electric Fuse

Surface Mount

35 V

200 mA

Wraparound

1.7 mJ

-55 °C (-67 °F)

Tin Over Nickel

35 A

200 ms

Tape And Reel, 7 inch

0.039 in (1 mm)

0.02 in (0.51 mm)

e3

0402

0.039 x 0.02 x 0.013 in (1 x 0.51 x 0.33 mm)

0.013 in (0.33 mm)

UL

90 °C (194 °F)

Fast

SF-0402FP200F-2

Bourns

Electric Fuse

Surface Mount

35 V

2 A

Wraparound

120 mJ

-55 °C (-67 °F)

Tin Over Nickel

35 A

200 ms

Tape And Reel, 7 inch

0.039 in (1 mm)

0.02 in (0.51 mm)

e3

0402

0.039 x 0.02 x 0.013 in (1 x 0.51 x 0.33 mm)

0.013 in (0.33 mm)

UL

90 °C (194 °F)

Fast

0437008.WRA

Littelfuse

Electric Fuse

Surface Mount

32 V

35 V

8 A

Wraparound

7.23 J

-55 °C (-67 °F)

50 A

1 s

Tape And Reel

0.126 in (3.2 mm)

0.064 in (1.63 mm)

1206

0.033 in (0.835 mm)

AEC-Q200; CSA; CUL; UL

150 °C (302 °F)

Fast

SF-0402FP050F-2

Bourns

Electric Fuse

Surface Mount

35 V

500 mA

Wraparound

6 mJ

-55 °C (-67 °F)

Tin Over Nickel

35 A

200 ms

Tape And Reel, 7 inch

0.039 in (1 mm)

0.02 in (0.51 mm)

e3

0402

0.039 x 0.02 x 0.013 in (1 x 0.51 x 0.33 mm)

0.013 in (0.33 mm)

UL

90 °C (194 °F)

Fast

SF-0402FP150F-2

Bourns

Electric Fuse

Surface Mount

35 V

1.5 A

Wraparound

81 mJ

-55 °C (-67 °F)

Tin Over Nickel

35 A

200 ms

Tape And Reel, 7 inch

0.039 in (1 mm)

0.02 in (0.51 mm)

e3

0402

0.039 x 0.02 x 0.013 in (1 x 0.51 x 0.33 mm)

0.013 in (0.33 mm)

UL

90 °C (194 °F)

Fast

SF-0603SA300M-2

Bourns

Electric Fuse

Surface Mount

35 V

3 A

Wraparound

343 mJ

-55 °C (-67 °F)

Tin with Nickel barrier

50 A

5 s

Tape And Reel, 7 inch

0.063 in (1.6 mm)

0.031 in (0.8 mm)

e3

1 ms

0603

0.031 in (0.8 mm)

AEC-Q200; UL

150 °C (302 °F)

Slow

0437008.WR

Littelfuse

Electric Fuse

Surface Mount

32 V

35 V

8 A

Wraparound

7.23 J

-55 °C (-67 °F)

Matte Tin Over Nickel

50 A

1 s

7.23

Tape And Reel

0.126 in (3.2 mm)

0.064 in (1.63 mm)

e3

35 V

1206

0.126 x 0.064 x 0.032 in (3.2 x 1.63 x 0.82 mm)

0.033 in (0.835 mm)

CSA; CUL; UL

150 °C (302 °F)

Fast

SF-0402FP025F-2

Bourns

Electric Fuse

Surface Mount

35 V

250 mA

Wraparound

3.5 mJ

-55 °C (-67 °F)

Tin Over Nickel

35 A

200 ms

Tape And Reel, 7 inch

0.039 in (1 mm)

0.02 in (0.51 mm)

e3

0402

0.039 x 0.02 x 0.013 in (1 x 0.51 x 0.33 mm)

0.013 in (0.33 mm)

UL

90 °C (194 °F)

Fast

SF-1206HV12M-2

Bourns

Electric Fuse

Surface Mount

35 V

Wraparound

20 J

-55 °C (-67 °F)

150 A

Tape And Reel, 7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

5 s

1206

0.126 x 0.063 x 0.038 in (3.2 x 1.6 x 0.97 mm)

0.038 in (0.97 mm)

UL

125 °C (257 °F)

SF-1206HV15M-2

Bourns

Electric Fuse

Surface Mount

35 V

Wraparound

35 J

-55 °C (-67 °F)

150 A

Tape And Reel, 7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

5 s

1206

0.126 x 0.063 x 0.038 in (3.2 x 1.6 x 0.97 mm)

0.038 in (0.97 mm)

UL

125 °C (257 °F)

SF-1206HV30M-2

Bourns

Electric Fuse

Surface Mount

35 V

Wraparound

180 J

-55 °C (-67 °F)

200 A

Tape And Reel, 7 inch

0.126 in (3.2 mm)

0.063 in (1.6 mm)

5 s

1206

0.126 x 0.063 x 0.051 in (3.2 x 1.6 x 1.3 mm)

0.051 in (1.3 mm)

UL

125 °C (257 °F)

0603SFF200FM/32

Littelfuse

Electric Fuse

Surface Mount

35 V

2 A

End Cap

-55 °C (-67 °F)

Tin Over Nickel

Rated Breaking Capacity at 32 VDC: 35 A

0.069 in (1.75 mm)

0.037 in (0.95 mm)

e3

0.069 x 0.037 x 0.037 in (1.75 x 0.95 x 0.95 mm)

0.037 in (0.95 mm)

UL

125 °C (257 °F)

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.