Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

NH3G500

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

500 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

3.307 in (84 mm)

2.83 in (71.88 mm)

Indicator

3.307 x 2.83 x 2.835 in (84 x 71.88 x 72 mm)

2.835 in (72 mm)

VDE

NH00CM10

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

10 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00M100

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

100 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH2M315

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

315 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.921 in (74.2 mm)

1.969 in (50 mm)

Indicator

2.921 x 1.969 x 2.835 in (74.2 x 50 x 72 mm)

2.835 in (72 mm)

VDE

NH3M500

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

500 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

3.307 in (84 mm)

2.83 in (71.88 mm)

Indicator

3.307 x 2.83 x 2.835 in (84 x 71.88 x 72 mm)

2.835 in (72 mm)

VDE

NH1M200

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

200 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.559 in (65 mm)

1.575 in (40 mm)

Indicator

2.559 x 1.575 x 2.835 in (65 x 40 x 72 mm)

2.835 in (72 mm)

VDE

NH00M80

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

80 A

Tab/Blade

120 kA

NH

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH1M250

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

250 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.559 in (65 mm)

1.575 in (40 mm)

Indicator

2.559 x 1.575 x 2.835 in (65 x 40 x 72 mm)

2.835 in (72 mm)

VDE

NH2CG50

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

50 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.402 in (61 mm)

1.575 in (40 mm)

Indicator

2.402 x 1.575 x 2.835 in (61 x 40 x 72 mm)

2.835 in (72 mm)

VDE

NH00M32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH0G16

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

16 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

NH1G224

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

224 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.559 in (65 mm)

1.575 in (40 mm)

Indicator

2.559 x 1.575 x 2.835 in (65 x 40 x 72 mm)

2.835 in (72 mm)

VDE

NH00CG35

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

35 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH2CG125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.402 in (61 mm)

1.575 in (40 mm)

Indicator

2.402 x 1.575 x 2.835 in (61 x 40 x 72 mm)

2.835 in (72 mm)

VDE

NH0G100

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

100 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

NH3G630

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

630 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

3.307 in (84 mm)

2.83 in (71.88 mm)

Indicator

3.307 x 2.83 x 2.835 in (84 x 71.88 x 72 mm)

2.835 in (72 mm)

VDE

NH2CG250

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

250 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.402 in (61 mm)

1.575 in (40 mm)

Indicator

2.402 x 1.575 x 2.835 in (61 x 40 x 72 mm)

2.835 in (72 mm)

VDE

NH0G20

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

20 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

NH3M630

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

630 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

3.307 in (84 mm)

2.83 in (71.88 mm)

Indicator

3.307 x 2.83 x 2.835 in (84 x 71.88 x 72 mm)

2.835 in (72 mm)

VDE

NH00CG25

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

25 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00M6

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

6 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH00M50

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

50 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH1CG63

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

63 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

NH00CG10

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

10 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH2CG63

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

63 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.402 in (61 mm)

1.575 in (40 mm)

Indicator

2.402 x 1.575 x 2.835 in (61 x 40 x 72 mm)

2.835 in (72 mm)

VDE

NH00CM32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00M20

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

20 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH00M125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

NH

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH00CG32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00M4

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

4 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH00M25

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

25 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH00CM100

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

100 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH1CG125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

NH1M224

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

224 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.559 in (65 mm)

1.575 in (40 mm)

Indicator

2.559 x 1.575 x 2.835 in (65 x 40 x 72 mm)

2.835 in (72 mm)

VDE

NH00M40

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

40 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH2G300

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

300 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.921 in (74.2 mm)

1.969 in (50 mm)

Indicator

2.921 x 1.969 x 2.835 in (74.2 x 50 x 72 mm)

2.835 in (72 mm)

VDE

NH0G125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

NH3CG315

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

315 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.921 in (74.2 mm)

1.969 in (50 mm)

Indicator

2.921 x 1.969 x 2.835 in (74.2 x 50 x 72 mm)

2.835 in (72 mm)

VDE

NH1M125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.559 in (65 mm)

1.575 in (40 mm)

Indicator

2.559 x 1.575 x 2.835 in (65 x 40 x 72 mm)

2.835 in (72 mm)

VDE

NH2M160

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

160 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.921 in (74.2 mm)

1.969 in (50 mm)

Indicator

2.921 x 1.969 x 2.835 in (74.2 x 50 x 72 mm)

2.835 in (72 mm)

VDE

NH00M16

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

16 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH1CG35

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

35 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

NH2CG80

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

80 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.402 in (61 mm)

1.575 in (40 mm)

Indicator

2.402 x 1.575 x 2.835 in (61 x 40 x 72 mm)

2.835 in (72 mm)

VDE

NH00CM2

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

2 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH1G250

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

250 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.559 in (65 mm)

1.575 in (40 mm)

Indicator

2.559 x 1.575 x 2.835 in (65 x 40 x 72 mm)

2.835 in (72 mm)

VDE

NH00CM80

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

80 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH2CG100

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

100 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.402 in (61 mm)

1.575 in (40 mm)

Indicator

2.402 x 1.575 x 2.835 in (61 x 40 x 72 mm)

2.835 in (72 mm)

VDE

NH00G160

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

160 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.126 in (56.4 x 30 x 54 mm)

2.126 in (54 mm)

VDE

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.