Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
15 A |
End Cap |
100 kA |
Rated Breaking Capacity = 20.25A-10kA |
Bulk |
0.394 in (10 mm) |
600 V |
Midget |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
CSA; UL |
Fast |
||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
10 A |
End Cap |
100 kA |
Rated Breaking Capacity = 13.5A-10kA |
Bulk |
0.394 in (10 mm) |
600 V |
Midget |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
CSA; UL |
Fast |
||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
5 A |
End Cap |
100 kA |
Rated Breaking Capacity = 6.75A-10kA |
Bulk |
0.394 in (10 mm) |
600 V |
Midget |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
CSA; UL |
Fast |
||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
20 A |
End Cap |
100 kA |
Rated Breaking Capacity = 27A-10kA |
Bulk |
0.394 in (10 mm) |
600 V |
Midget |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
CSA; UL |
Fast |
||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
3 A |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
0.394 in (10 mm) |
600 V |
Midget |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
CSA; UL |
Fast |
|||||||||||||||
|
Bel Fuse |
Electric Fuse |
Surface Mount |
350 V |
600 V |
1.25 A |
Wraparound |
950 mJ |
-40 °C (-40 °F) |
100 A |
2 m |
Tape And Reel, 13 inch |
0.52 in (13.2 mm) |
0.199 in (5.05 mm) |
0.199 in (5.05 mm) |
AEC-Q200; CUL; UL |
125 °C (257 °F) |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
3 A |
End Cap |
-55 °C (-67 °F) |
100 kA |
4 m |
0.406 in (10.31 mm) |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 x 1.5 in (38.1 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; IEC; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
5 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
600 V |
1 A |
Wraparound |
304.4 mJ |
-55 °C (-67 °F) |
Silver |
100 A |
1 m |
Tape And Reel |
0.476 in (12.1 mm) |
0.177 in (4.5 mm) |
e4 |
250 V |
Nano |
0.177 in (4.5 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
|||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
3 A |
End Cap |
Nickel |
200 kA |
Box |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Time Delay |
||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
25 A |
End Cap |
100 kA |
Rated Breaking Capacity = 33.75A-10kA |
Bulk |
0.394 in (10 mm) |
600 V |
Midget |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
CSA; UL |
Fast |
||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
30 A |
End Cap |
100 kA |
Rated Breaking Capacity = 40.5A-10kA |
Bulk |
0.394 in (10 mm) |
600 V |
Midget |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
CSA; UL |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
4 A |
End Cap |
19 mJ |
-55 °C (-67 °F) |
Nickel |
100 kA |
4 m |
0.406 in (10.31 mm) |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 x 1.5 in (38.1 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; IEC; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
500 mA |
End Cap |
41 mJ |
-55 °C (-67 °F) |
10 kA |
2 m |
Bulk |
0.25 in (6.35 mm) |
600 V |
0.236 x 1.26 in (6 x 32 mm) |
1.252 in (31.8 mm) |
CUL; UL |
105 °C (221 °F) |
Fast |
||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
30 A |
End Cap |
200 kA |
Rated Breaking Capacity = 40.5A-10kA |
Bulk |
0.409 in (10.4 mm) |
0.409 x 1.5 in (10.4 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
||||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
15 A |
End Cap |
51.64 J |
-55 °C (-67 °F) |
150 kA |
4 m |
Rated Breaking Capacity at 600 VDC: 10000 A |
Bulk |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; TUV; UL |
125 °C (257 °F) |
|||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
20 A |
End Cap |
206.48 J |
-55 °C (-67 °F) |
150 kA |
4 m |
Rated Breaking Capacity at 600 VDC: 10000 A |
Bulk |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; TUV; UL |
125 °C (257 °F) |
|||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
25 A |
End Cap |
1.607 kJ |
-55 °C (-67 °F) |
150 kA |
4 m |
Rated Breaking Capacity at 600 VDC: 10000 A |
Bulk |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; TUV; UL |
125 °C (257 °F) |
|||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
20 A |
End Cap |
100 kA |
Bulk |
0.406 in (10.3 mm) |
CC |
600 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Fast |
||||||||||||||
|
Bel Fuse |
Electric Fuse |
Through Hole Mount |
600 V |
600 V |
10 A |
Pin Wire |
101.4 J |
-55 °C (-67 °F) |
10 kA |
2 m |
Bulk |
0.266 in (6.76 mm) |
600 V |
0.236 x 1.26 in (6 x 32 mm) |
1.291 in (32.8 mm) |
CUL; UL |
105 °C (221 °F) |
Fast |
||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
20 A |
End Cap |
200 kA |
Rated Breaking Capacity = 27A-10kA |
Bulk |
0.409 in (10.4 mm) |
0.409 x 1.5 in (10.4 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Panel Mount |
600 V |
600 V |
30 A |
-20 °C (-4 °F) |
200 kA |
3.831 in (97.3 mm) |
2.244 in (57 mm) |
CC |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
3.504 in (89 mm) |
CE |
90 °C (194 °F) |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
25 A |
End Cap |
2.085 kJ |
-55 °C (-67 °F) |
Nickel |
100 kA |
4 m |
0.406 in (10.31 mm) |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 x 1.5 in (38.1 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; IEC; UL |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
2.5 A |
End Cap |
-55 °C (-67 °F) |
100 kA |
4 m |
0.406 in (10.31 mm) |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 x 1.5 in (38.1 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; IEC; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
2.5 A |
End Cap |
5.142 J |
-55 °C (-67 °F) |
100 kA |
4 m |
Pre Arcing Time: Clear within 4 m at 200% Rated Current; Rated Breaking Capacity at 600 VDC: 50000 A |
Bulk |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
100 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 600 VDC: 100000 A |
1.339 in (34 mm) |
Indicator |
7.874 in (200 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
1 A |
End Cap |
100 kA |
Bulk |
0.406 in (10.3 mm) |
CC |
600 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
200 A |
Threaded |
3.012 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.969 in (50 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
1 A |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
0.394 in (10 mm) |
600 V |
Midget |
0.394 x 1.496 in (10 x 38 mm) |
1.496 in (38 mm) |
CSA; UL |
Fast |
|||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
25 A |
End Cap |
200 kA |
Rated Breaking Capacity = 33.75A-10kA |
Bulk |
0.409 in (10.4 mm) |
0.409 x 1.5 in (10.4 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
75 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 600 VDC: 20000 A |
Bulk |
1.283 in (32.6 mm) |
7.874 in (200 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
4 A |
End Cap |
100 kA |
Bulk |
0.406 in (10.3 mm) |
CC |
600 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Fast |
||||||||||||||
|
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
5 A |
End Cap |
200 kA |
Rated Breaking Capacity = 6.75A-10kA |
Bulk |
0.409 in (10.4 mm) |
0.409 x 1.5 in (10.4 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
300 mA |
End Cap |
100 kA |
Bulk |
0.406 in (10.3 mm) |
CC |
600 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
125 A |
Tab/Blade |
707 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
30 A |
End Cap |
100 kA |
Bulk |
0.406 in (10.3 mm) |
CC |
600 V |
Midget |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE, CSA, UL |
Fast |
||||||||||||||
|
Bourns |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
30 A |
End Cap |
1.74 kJ |
-55 °C (-67 °F) |
150 kA |
4 m |
Rated Breaking Capacity at 600 VDC: 10000 A |
Bulk |
0.406 in (10.3 mm) |
5AG |
1.496 in (38 mm) |
CUL; TUV; UL |
125 °C (257 °F) |
|||||||||||||
Mersen S A |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
1.4 A |
End Cap |
200 kA |
Rated Breaking Capacity at 600 VDC: 20000 A |
0.827 in (21 mm) |
5 in (127 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
80 A |
Tab/Blade |
-40 °C (-40 °F) |
200 kA |
Pre Arcing Time: Clear within 8 m at 200% Rated Current; Rated Breaking Capacity at 600 VDC: 50000 A |
Box |
2.992 in (76 mm) |
0.984 in (25 mm) |
1.26 in (32 mm) |
CE; CSA; UL |
80 °C (176 °F) |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
1 A |
End Cap |
8 mJ |
-55 °C (-67 °F) |
100 kA |
4 m |
0.406 in (10.31 mm) |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 x 1.5 in (38.1 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; IEC; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
200 A |
Tab/Blade |
200 kA |
16 ms |
Rated Breaking Capacity at 600 VDC: 50000 A |
2.5 in (63.5 mm) |
L |
600 V |
2.5 x 3.752 in (63.5 x 95.3 mm) |
3.752 in (95.3 mm) |
CE, UL |
Fast |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
80 A |
Tab/Blade |
304 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
600 V |
3.15 A |
Wraparound |
3.304 J |
-55 °C (-67 °F) |
Silver |
100 A |
1 m |
Tape And Reel |
0.476 in (12.1 mm) |
0.177 in (4.5 mm) |
e4 |
250 V |
Nano |
0.177 in (4.5 mm) |
CSA; UL |
125 °C (257 °F) |
Fast |
|||||||||
|
Eaton Corporation |
Electric Fuse |
Through Hole Mount |
600 V |
600 V |
2 A |
Pin Wire |
-55 °C (-67 °F) |
10 kA |
Box |
0.275 in (6.98 mm) |
120 s |
3AB |
1.288 in (32.72 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Through Hole Mount |
600 V |
600 V |
2 A |
Pin Wire |
-55 °C (-67 °F) |
10 kA |
Box |
0.275 in (6.98 mm) |
120 s |
3AB |
1.288 in (32.72 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
15 A |
End Cap |
137.333 J |
-55 °C (-67 °F) |
Nickel |
100 kA |
544 µs |
Rated Breaking Capacity at 600 VDC: 50000 A |
Bulk |
0.406 in (10.31 mm) |
1.721 ms |
0.394 x 1.496 in (10 x 38 mm) |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA, IEC, UL, VDE |
125 °C (257 °F) |
Fast |
|||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
5 A |
End Cap |
60 J |
200 kA |
Rated Breaking Capacity at 600 VDC: 100000 A |
0.406 in (10.32 mm) |
0.406 x 1.5 in (10.32 x 38.1 mm) |
1.5 in (38.1 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
550 A |
Tab/Blade |
44.323 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.