One Surface Fuses 20

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

F0603G0R10FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

63 V

63 V

100 mA

One Surface

7 μJ

-55 °C (-67 °F)

50 A

Tape And Reel, 7 inch

0.063 in (1.6 mm)

0.032 in (0.81 mm)

0603

0.063 x 0.032 x 0.024 in (1.6 x 0.81 x 0.61 mm)

0.024 in (0.61 mm)

CUL; UL

125 °C (257 °F)

Fast

F0603G0R05FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

63 V

63 V

50 mA

One Surface

2 μJ

-55 °C (-67 °F)

Nickel

50 A

Tape And Reel, 7 inch

0.063 in (1.6 mm)

0.032 in (0.81 mm)

32 V

0603

0.063 x 0.032 x 0.024 in (1.6 x 0.81 x 0.61 mm)

0.024 in (0.61 mm)

CUL; UL

125 °C (257 °F)

Fast

F0603G0R02FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

63 V

63 V

28 mA

One Surface

600 nJ

-55 °C (-67 °F)

50 A

Tape And Reel, 7 inch

0.063 in (1.6 mm)

0.032 in (0.81 mm)

0603

0.024 in (0.61 mm)

CUL; UL

125 °C (257 °F)

Fast

F0402G0R10FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

32 V

32 V

100 mA

One Surface

7 μJ

-55 °C (-67 °F)

Tin with Nickel barrier

50 A

Tape And Reel, 7 inch

0.039 in (1 mm)

0.023 in (0.58 mm)

e3

0402

0.014 in (0.35 mm)

CUL; UL

125 °C (257 °F)

Fast

SCF4030-12-04

Eaton Corporation

Electric Fuse

Surface Mount

36 V

12 A

One Surface

-20 °C (-4 °F)

50 A

1 m

Tape And Reel, 13 inch

0.157 in (4 mm)

0.118 in (3 mm)

0.157 x 0.118 in (4 x 3 mm)

0.033 in (0.85 mm)

CUL; UL

60 °C (140 °F)

Fast

SCF9550-30-05

Eaton Corporation

Electric Fuse

Surface Mount

62 V

30 A

One Surface

-20 °C (-4 °F)

80 A

1 m

Tape And Reel, 13 inch

0.374 in (9.5 mm)

0.197 in (5 mm)

0.374 x 0.197 in (9.5 x 5 mm)

0.079 in (2 mm)

CUL; UL

60 °C (140 °F)

Fast

SCF9550-45-07

Eaton Corporation

Electric Fuse

Surface Mount

80 V

45 A

One Surface

-20 °C (-4 °F)

120 A

1 m

Tape And Reel, 13 inch

0.374 in (9.5 mm)

0.197 in (5 mm)

0.374 x 0.197 in (9.5 x 5 mm)

0.079 in (2 mm)

CUL; UL

60 °C (140 °F)

Fast

F0603G0R12FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

63 V

63 V

125 mA

One Surface

10 μJ

-55 °C (-67 °F)

50 A

Tape And Reel, 7 inch

0.063 in (1.6 mm)

0.032 in (0.81 mm)

0603

0.063 x 0.032 x 0.024 in (1.6 x 0.81 x 0.61 mm)

0.024 in (0.61 mm)

CUL; UL

125 °C (257 °F)

Fast

F0603G0R20FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

63 V

63 V

200 mA

One Surface

40 μJ

-55 °C (-67 °F)

50 A

Tape And Reel, 7 inch

0.063 in (1.6 mm)

0.032 in (0.81 mm)

0603

0.063 x 0.032 x 0.024 in (1.6 x 0.81 x 0.61 mm)

0.024 in (0.61 mm)

CUL; UL

125 °C (257 °F)

Fast

F0603G0R06FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

63 V

63 V

62 mA

One Surface

2 μJ

-55 °C (-67 °F)

Nickel

50 A

Tape And Reel, 7 inch

0.063 in (1.6 mm)

0.032 in (0.81 mm)

0603

0.063 x 0.032 x 0.024 in (1.6 x 0.81 x 0.61 mm)

0.024 in (0.61 mm)

CUL; UL

125 °C (257 °F)

Fast

F0402G0R12FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

32 V

32 V

125 mA

One Surface

10 μJ

-55 °C (-67 °F)

Tin with Nickel barrier

50 A

Tape And Reel, 7 inch

0.039 in (1 mm)

0.023 in (0.58 mm)

e3

0402

0.014 in (0.35 mm)

CUL; UL

125 °C (257 °F)

Fast

SCF9550-45-04

Eaton Corporation

Electric Fuse

Surface Mount

80 V

45 A

One Surface

-20 °C (-4 °F)

120 A

1 m

Tape And Reel, 13 inch

0.374 in (9.5 mm)

0.197 in (5 mm)

0.374 x 0.197 in (9.5 x 5 mm)

0.079 in (2 mm)

CUL; UL

60 °C (140 °F)

Fast

SCF4030-12-01

Eaton Corporation

Electric Fuse

Surface Mount

36 V

12 A

One Surface

-20 °C (-4 °F)

50 A

1 m

Tape And Reel, 13 inch

0.157 in (4 mm)

0.118 in (3 mm)

0.157 x 0.118 in (4 x 3 mm)

0.033 in (0.85 mm)

CUL; UL

60 °C (140 °F)

Fast

SCF4030-12-02

Eaton Corporation

Electric Fuse

Surface Mount

36 V

12 A

One Surface

-20 °C (-4 °F)

50 A

1 m

Tape And Reel, 13 inch

0.157 in (4 mm)

0.118 in (3 mm)

0.157 x 0.118 in (4 x 3 mm)

0.033 in (0.85 mm)

CUL; UL

60 °C (140 °F)

Fast

SCF9550-45-06

Eaton Corporation

Electric Fuse

Surface Mount

80 V

45 A

One Surface

-20 °C (-4 °F)

120 A

1 m

Tape And Reel, 13 inch

0.374 in (9.5 mm)

0.197 in (5 mm)

0.374 x 0.197 in (9.5 x 5 mm)

0.079 in (2 mm)

60 °C (140 °F)

Fast

F0402G0R02FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

32 V

32 V

28 mA

One Surface

600 nJ

-55 °C (-67 °F)

50 A

Tape And Reel, 7 inch

0.039 in (1 mm)

0.023 in (0.58 mm)

0402

0.014 in (0.35 mm)

CUL; UL

125 °C (257 °F)

Fast

F0402G0R05FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

32 V

32 V

50 mA

One Surface

2 μJ

-55 °C (-67 °F)

Tin with Nickel barrier

50 A

Tape And Reel, 7 inch

0.039 in (1 mm)

0.023 in (0.58 mm)

e3

0402

0.014 in (0.35 mm)

CUL; UL

125 °C (257 °F)

Fast

F0402G0R15FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

32 V

32 V

150 mA

One Surface

20 μJ

-55 °C (-67 °F)

Tin with Nickel barrier

50 A

Tape And Reel, 7 inch

0.039 in (1 mm)

0.023 in (0.58 mm)

e3

0402

0.014 in (0.35 mm)

CUL; UL

125 °C (257 °F)

Fast

F0603G0R03FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

63 V

63 V

37.5 mA

One Surface

800 nJ

-55 °C (-67 °F)

50 A

Tape And Reel, 7 inch

0.063 in (1.6 mm)

0.032 in (0.81 mm)

0603

0.024 in (0.61 mm)

CUL; UL

125 °C (257 °F)

Fast

F0603G0R07FNTR

KYOCERA AVX

Electric Fuse

Surface Mount

63 V

63 V

75 mA

One Surface

4 μJ

-55 °C (-67 °F)

50 A

Tape And Reel, 7 inch

0.063 in (1.6 mm)

0.032 in (0.81 mm)

0603

0.063 x 0.032 x 0.024 in (1.6 x 0.81 x 0.61 mm)

0.024 in (0.61 mm)

CUL; UL

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.