Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
32 V |
32 V |
20 A |
Wire |
203 J |
-60 °C (-76 °F) |
Tin |
100 A |
10 s |
Rated Breaking Capacity at 32 VDC: 300 A |
203 |
Bulk |
0.133 in (3.38 mm) |
e3 |
32 V |
Pico |
0.133 x 0.31 in (3.38 x 7.87 mm) |
0.31 in (7.87 mm) |
CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
15 A |
Wire |
1.237 kJ |
-55 °C (-67 °F) |
Tin |
500 A |
Bulk |
0.228 in (5.8 mm) |
e3 |
250 V |
10 µs |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CCC; CE; CSA; CUL; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
4 A |
Wire |
46.96 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
Bulk |
0.228 in (5.8 mm) |
e3 |
250 V |
10 µs |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CCC; CE; CQC; CSA; CUL; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
300 V |
300 V |
800 mA |
Wire |
12.48 kJ |
-40 °C (-40 °F) |
Tin |
100 A |
1 s |
Bulk |
0.488 in (12.4 mm) |
0.252 in (6.4 mm) |
e3 |
300 V |
0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm) |
0.362 in (9.2 mm) |
IEC; CUL; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
300 V |
300 V |
1.25 A |
Wire |
3 kJ |
-40 °C (-40 °F) |
Tin |
100 A |
1 s |
Ammo Pack |
0.488 in (12.4 mm) |
0.252 in (6.4 mm) |
e3 |
300 V |
0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm) |
0.362 in (9.2 mm) |
IEC; CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
800 mA |
Wire |
975 mJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
Bulk |
0.236 in (6 mm) |
e3 |
250 V |
5 µs |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CE; CSA; CUL; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
15 mA |
Wire |
1.23 μJ |
-55 °C (-67 °F) |
10 kA |
5 s |
Bulk |
0.25 in (6.35 mm) |
125 V |
Micro |
0.35 in (8.89 mm) |
CSA; QPL; UL |
85 °C (185 °F) |
Very Fast |
|||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
100 mA |
Wire |
385 μJ |
-55 °C (-67 °F) |
10 kA |
5 s |
Bulk |
0.25 in (6.35 mm) |
125 V |
Micro |
0.35 in (8.89 mm) |
CSA; QPL; UL |
85 °C (185 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
3.15 A |
Wire |
43.255 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
Bulk |
0.228 in (5.8 mm) |
e3 |
250 V |
10 µs |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CCC; CE; CSA; CUL; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
800 mA |
Wire |
113 mJ |
-55 °C (-67 °F) |
10 kA |
2 s |
Bulk |
0.25 in (6.35 mm) |
125 V |
Micro |
0.35 in (8.89 mm) |
CSA; QPL; UL |
85 °C (185 °F) |
Very Fast |
|||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
1 A |
Wire |
64.8 mJ |
-55 °C (-67 °F) |
10 kA |
2 s |
Bulk |
0.25 in (6.35 mm) |
125 V |
Micro |
0.35 in (8.89 mm) |
CSA; QPL; UL |
85 °C (185 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
2.5 A |
Wire |
22.29 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
Tape And Reel |
0.228 in (5.8 mm) |
e3 |
250 V |
10 µs |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CCC; CE; CQC; CSA; CUL; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
300 V |
300 V |
4 A |
Wire |
36.8 kJ |
-40 °C (-40 °F) |
Tin |
100 A |
1 s |
Bulk |
0.488 in (12.4 mm) |
0.252 in (6.4 mm) |
e3 |
300 V |
0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm) |
0.362 in (9.2 mm) |
IEC; CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
3.15 A |
Wire |
212.94 J |
-40 °C (-40 °F) |
Tin |
150 A |
1 s |
Ammo Pack |
0.488 in (12.4 mm) |
0.252 in (6.4 mm) |
e3 |
250 V |
TE7 |
0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm) |
0.362 in (9.2 mm) |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
300 V |
300 V |
1 A |
Wire |
20 kJ |
-40 °C (-40 °F) |
Tin |
100 A |
1 s |
Ammo Pack |
0.488 in (12.4 mm) |
0.252 in (6.4 mm) |
e3 |
300 V |
0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm) |
0.362 in (9.2 mm) |
IEC; CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
125 mA |
Wire |
691 μJ |
-55 °C (-67 °F) |
10 kA |
5 s |
Bulk |
0.25 in (6.35 mm) |
125 V |
Micro |
0.35 in (8.89 mm) |
CSA; QPL; UL |
85 °C (185 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.6 A |
Wire |
12.67 J |
-40 °C (-40 °F) |
Tin |
100 A |
150 ms |
9 |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CCC; CE; CUL; PSE; UL; VDE |
85 °C (185 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
4 A |
Wire |
72 J |
-40 °C (-40 °F) |
Matte Tin |
100 A |
150 ms |
58 |
Ammo Pack |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CCC; CE; CUL; PSE; UL; VDE |
85 °C (185 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
4 A |
Wire |
14.995 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
10 ms |
Bulk |
0.228 in (5.8 mm) |
e3 |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CCC, CE, CSA, PSE, UL, VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
315 mA |
Wire |
975 mJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
Bulk |
0.236 in (6 mm) |
e3 |
250 V |
5 µs |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CE; CUL; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
32 V |
32 V |
20 A |
Wire |
203 J |
-60 °C (-76 °F) |
Tin |
100 A |
10 s |
Rated Breaking Capacity at 32 VDC: 300 A |
203 |
Tape And Reel |
0.133 in (3.38 mm) |
e3 |
32 V |
Pico |
0.133 x 0.31 in (3.38 x 7.87 mm) |
0.31 in (7.87 mm) |
CUL; UL |
125 °C (257 °F) |
Very Fast |
|||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
2 A |
Wire |
2.645 J |
-55 °C (-67 °F) |
100 A |
5 s |
Bulk |
0.197 in (5 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
125 °C (257 °F) |
Fast |
||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
500 mA |
Wire |
71.6 mJ |
-55 °C (-67 °F) |
10 kA |
2 s |
Bulk |
0.25 in (6.35 mm) |
125 V |
Micro |
0.35 in (8.89 mm) |
CSA; QPL; UL |
85 °C (185 °F) |
Very Fast |
|||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
15 mA |
Wire |
1.23 μJ |
-55 °C (-67 °F) |
10 kA |
5 s |
Bulk |
0.25 in (6.35 mm) |
125 V |
Micro |
0.35 in (8.89 mm) |
CSA; QPL; UL |
85 °C (185 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1 A |
Wire |
467.5 mJ |
-55 °C (-67 °F) |
Tin |
100 A |
5 s |
Bulk |
0.217 in (5.5 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.846 in (21.5 mm) |
CE, CSA, PSE, UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
16 A |
Wire |
1.408 kJ |
-55 °C (-67 °F) |
Tin |
500 A |
Bulk |
0.228 in (5.8 mm) |
e3 |
250 V |
10 µs |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CCC; CE; CSA; CUL; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
5 A |
Wire |
27.41 J |
-55 °C (-67 °F) |
10 kA |
5 s |
Bulk |
0.197 in (5 mm) |
125 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
125 °C (257 °F) |
Fast |
||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
125 mA |
Wire |
691 μJ |
-55 °C (-67 °F) |
10 kA |
5 s |
Bulk |
0.235 in (5.97 mm) |
125 V |
Micro |
0.287 in (7.3 mm) |
CSA; QPL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
8 A |
Wire |
233.6 J |
-40 °C (-40 °F) |
Tin |
100 A |
150 ms |
180 |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CUL; PSE; UL |
85 °C (185 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
800 mA |
Wire |
253 mJ |
-55 °C (-67 °F) |
35 A |
5 s |
Bulk |
0.197 in (5 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CSA, CE, UL |
125 °C (257 °F) |
Fast |
|||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
2 mA |
Wire |
-55 °C (-67 °F) |
10 kA |
5 s |
Bulk |
0.25 in (6.35 mm) |
125 V |
Micro |
0.35 in (8.89 mm) |
CSA; QPL; UL |
85 °C (185 °F) |
Very Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.25 A |
Wire |
30 J |
-40 °C (-40 °F) |
Tin |
150 A |
1 s |
Bulk |
0.488 in (12.4 mm) |
0.252 in (6.4 mm) |
e3 |
250 V |
TE7 |
0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm) |
0.362 in (9.2 mm) |
125 °C (257 °F) |
Time Lag |
||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
15 mA |
Wire |
1.23 μJ |
-55 °C (-67 °F) |
10 kA |
5 s |
Bulk |
0.235 in (5.97 mm) |
125 V |
Micro |
0.287 in (7.3 mm) |
CSA; QPL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
50 mA |
Wire |
66.6 μJ |
-55 °C (-67 °F) |
10 kA |
5 s |
Bulk |
0.235 in (5.97 mm) |
125 V |
Micro |
0.287 in (7.3 mm) |
CSA; QPL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
300 V |
300 V |
2 A |
Wire |
8.8 kJ |
-40 °C (-40 °F) |
Tin |
100 A |
1 s |
Ammo Pack |
0.488 in (12.4 mm) |
0.252 in (6.4 mm) |
e3 |
300 V |
0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm) |
0.362 in (9.2 mm) |
IEC; CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
7 A |
Wire |
64.815 J |
-55 °C (-67 °F) |
Tin |
10 kA |
5 s |
Bulk |
0.217 in (5.5 mm) |
e3 |
125 V |
0.197 x 0.787 in (5 x 20 mm) |
0.846 in (21.5 mm) |
CE, PSE, UL |
125 °C (257 °F) |
Fast |
|||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
5 A |
Wire |
2.21 J |
-55 °C (-67 °F) |
10 kA |
2 s |
Bulk |
0.235 in (5.97 mm) |
125 V |
Micro |
0.287 in (7.3 mm) |
CSA; QPL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
4 A |
Wire |
46.96 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
Bulk |
0.228 in (5.8 mm) |
e3 |
250 V |
10 µs |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CCC; CE; CQC; CSA; CUL; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
10 A |
Wire |
365 J |
-40 °C (-40 °F) |
Tin |
100 A |
150 ms |
260 |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CUL; PSE; UL |
85 °C (185 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.6 A |
Wire |
2.025 J |
-55 °C (-67 °F) |
100 A |
5 s |
Bulk |
0.197 in (5 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
160 mA |
Wire |
46.5 mJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
Bulk |
0.236 in (6 mm) |
e3 |
250 V |
5 µs |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CE; CUL; SEMKO; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
8 A |
Wire |
233.6 J |
-40 °C (-40 °F) |
Tin |
100 A |
150 ms |
180 |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CUL; PSE; UL |
85 °C (185 °F) |
Time Lag |
|||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
3 A |
Wire |
759 mJ |
-55 °C (-67 °F) |
10 kA |
2 s |
Bulk |
0.235 in (5.97 mm) |
125 V |
Micro |
0.287 in (7.3 mm) |
CSA; QPL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
800 mA |
Wire |
253 mJ |
-55 °C (-67 °F) |
Tin |
35 A |
5 s |
Bulk |
0.217 in (5.5 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.846 in (21.5 mm) |
CE, CSA, UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
4 A |
Wire |
17.14 J |
-55 °C (-67 °F) |
Tin |
10 kA |
5 s |
Bulk |
0.217 in (5.5 mm) |
e3 |
125 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.846 in (21.5 mm) |
CE, CSA, PSE, UL |
125 °C (257 °F) |
Fast |
||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
100 mA |
Wire |
385 μJ |
-55 °C (-67 °F) |
10 kA |
5 s |
Bulk |
0.235 in (5.97 mm) |
125 V |
Micro |
0.287 in (7.3 mm) |
CSA; QPL; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
4 A |
Wire |
1.38 J |
-55 °C (-67 °F) |
10 kA |
2 s |
Bulk |
0.25 in (6.35 mm) |
125 V |
Micro |
0.35 in (8.89 mm) |
CSA; QPL; UL |
85 °C (185 °F) |
Very Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
300 V |
300 V |
1 A |
Wire |
20 kJ |
-40 °C (-40 °F) |
Tin |
100 A |
1 s |
Bulk |
0.488 in (12.4 mm) |
0.252 in (6.4 mm) |
e3 |
300 V |
0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm) |
0.362 in (9.2 mm) |
IEC; CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.