Wire Fuses 266

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

0275020.VXL

Littelfuse

Electric Fuse

Through Hole Mount

32 V

32 V

20 A

Wire

203 J

-60 °C (-76 °F)

Tin

100 A

10 s

Rated Breaking Capacity at 32 VDC: 300 A

203

Bulk

0.133 in (3.38 mm)

e3

32 V

Pico

0.133 x 0.31 in (3.38 x 7.87 mm)

0.31 in (7.87 mm)

CUL; UL

125 °C (257 °F)

Very Fast

0215015.MXE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

15 A

Wire

1.237 kJ

-55 °C (-67 °F)

Tin

500 A

Bulk

0.228 in (5.8 mm)

e3

250 V

10 µs

0.197 x 0.787 in (5 x 20 mm)

0.886 in (22.5 mm)

CCC; CE; CSA; CUL; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0215004.MRET1

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Wire

46.96 J

-55 °C (-67 °F)

Tin

1.5 kA

Bulk

0.228 in (5.8 mm)

e3

250 V

10 µs

0.197 x 0.787 in (5 x 20 mm)

0.886 in (22.5 mm)

CCC; CE; CQC; CSA; CUL; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

80708000440

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

800 mA

Wire

12.48 kJ

-40 °C (-40 °F)

Tin

100 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

300 V

0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm)

0.362 in (9.2 mm)

IEC; CUL; UL

125 °C (257 °F)

Time Lag

80711250000

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

1.25 A

Wire

3 kJ

-40 °C (-40 °F)

Tin

100 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

300 V

0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm)

0.362 in (9.2 mm)

IEC; CUL; PSE; UL

125 °C (257 °F)

Time Lag

0215.800MXE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

800 mA

Wire

975 mJ

-55 °C (-67 °F)

Tin

1.5 kA

Bulk

0.236 in (6 mm)

e3

250 V

5 µs

0.197 x 0.787 in (5 x 20 mm)

0.886 in (22.5 mm)

CE; CSA; CUL; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

02740.015H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

15 mA

Wire

1.23 μJ

-55 °C (-67 °F)

10 kA

5 s

Bulk

0.25 in (6.35 mm)

125 V

Micro

0.35 in (8.89 mm)

CSA; QPL; UL

85 °C (185 °F)

Very Fast

02740.100H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

100 mA

Wire

385 μJ

-55 °C (-67 °F)

10 kA

5 s

Bulk

0.25 in (6.35 mm)

125 V

Micro

0.35 in (8.89 mm)

CSA; QPL; UL

85 °C (185 °F)

Very Fast

02153.15MXE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

3.15 A

Wire

43.255 J

-55 °C (-67 °F)

Tin

1.5 kA

Bulk

0.228 in (5.8 mm)

e3

250 V

10 µs

0.197 x 0.787 in (5 x 20 mm)

0.886 in (22.5 mm)

CCC; CE; CSA; CUL; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

02790.800H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

800 mA

Wire

113 mJ

-55 °C (-67 °F)

10 kA

2 s

Bulk

0.25 in (6.35 mm)

125 V

Micro

0.35 in (8.89 mm)

CSA; QPL; UL

85 °C (185 °F)

Very Fast

0274001.0H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

1 A

Wire

64.8 mJ

-55 °C (-67 °F)

10 kA

2 s

Bulk

0.25 in (6.35 mm)

125 V

Micro

0.35 in (8.89 mm)

CSA; QPL; UL

85 °C (185 °F)

Very Fast

021502.5MXE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2.5 A

Wire

22.29 J

-55 °C (-67 °F)

Tin

1.5 kA

Tape And Reel

0.228 in (5.8 mm)

e3

250 V

10 µs

0.197 x 0.787 in (5 x 20 mm)

0.886 in (22.5 mm)

CCC; CE; CQC; CSA; CUL; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

80714000440

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

4 A

Wire

36.8 kJ

-40 °C (-40 °F)

Tin

100 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

300 V

0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm)

0.362 in (9.2 mm)

IEC; CUL; PSE; UL

125 °C (257 °F)

Time Lag

80413150000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

3.15 A

Wire

212.94 J

-40 °C (-40 °F)

Tin

150 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80711000000

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

1 A

Wire

20 kJ

-40 °C (-40 °F)

Tin

100 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

300 V

0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm)

0.362 in (9.2 mm)

IEC; CUL; PSE; UL

125 °C (257 °F)

Time Lag

02790.125H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

125 mA

Wire

691 μJ

-55 °C (-67 °F)

10 kA

5 s

Bulk

0.25 in (6.35 mm)

125 V

Micro

0.35 in (8.89 mm)

CSA; QPL; UL

85 °C (185 °F)

Very Fast

38211600410

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.6 A

Wire

12.67 J

-40 °C (-40 °F)

Tin

100 A

150 ms

9

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38214000000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Wire

72 J

-40 °C (-40 °F)

Matte Tin

100 A

150 ms

58

Ammo Pack

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

0216004MXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

250 V

4 A

Wire

14.995 J

-55 °C (-67 °F)

Tin

1.5 kA

10 ms

Bulk

0.228 in (5.8 mm)

e3

0.197 x 0.787 in (5 x 20 mm)

0.886 in (22.5 mm)

CCC, CE, CSA, PSE, UL, VDE

125 °C (257 °F)

Fast

0215.315MXE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

315 mA

Wire

975 mJ

-55 °C (-67 °F)

Tin

1.5 kA

Bulk

0.236 in (6 mm)

e3

250 V

5 µs

0.197 x 0.787 in (5 x 20 mm)

0.886 in (22.5 mm)

CE; CUL; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0275020.VRT1L

Littelfuse

Electric Fuse

Through Hole Mount

32 V

32 V

20 A

Wire

203 J

-60 °C (-76 °F)

Tin

100 A

10 s

Rated Breaking Capacity at 32 VDC: 300 A

203

Tape And Reel

0.133 in (3.38 mm)

e3

32 V

Pico

0.133 x 0.31 in (3.38 x 7.87 mm)

0.31 in (7.87 mm)

CUL; UL

125 °C (257 °F)

Very Fast

0235002.HXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2 A

Wire

2.645 J

-55 °C (-67 °F)

100 A

5 s

Bulk

0.197 in (5 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

Fast

02740.500H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

500 mA

Wire

71.6 mJ

-55 °C (-67 °F)

10 kA

2 s

Bulk

0.25 in (6.35 mm)

125 V

Micro

0.35 in (8.89 mm)

CSA; QPL; UL

85 °C (185 °F)

Very Fast

02790.015H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

15 mA

Wire

1.23 μJ

-55 °C (-67 °F)

10 kA

5 s

Bulk

0.25 in (6.35 mm)

125 V

Micro

0.35 in (8.89 mm)

CSA; QPL; UL

85 °C (185 °F)

Very Fast

0235001.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Wire

467.5 mJ

-55 °C (-67 °F)

Tin

100 A

5 s

Bulk

0.217 in (5.5 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.846 in (21.5 mm)

CE, CSA, PSE, UL

125 °C (257 °F)

Fast

0215016.MRET1

Littelfuse

Electric Fuse

Through Hole Mount

250 V

16 A

Wire

1.408 kJ

-55 °C (-67 °F)

Tin

500 A

Bulk

0.228 in (5.8 mm)

e3

250 V

10 µs

0.197 x 0.787 in (5 x 20 mm)

0.886 in (22.5 mm)

CCC; CE; CSA; CUL; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

0235005.HXEP

Littelfuse

Electric Fuse

Through Hole Mount

125 V

5 A

Wire

27.41 J

-55 °C (-67 °F)

10 kA

5 s

Bulk

0.197 in (5 mm)

125 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

Fast

02780.125H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

125 mA

Wire

691 μJ

-55 °C (-67 °F)

10 kA

5 s

Bulk

0.235 in (5.97 mm)

125 V

Micro

0.287 in (7.3 mm)

CSA; QPL; UL

125 °C (257 °F)

Very Fast

38218000410

Littelfuse

Electric Fuse

Through Hole Mount

250 V

8 A

Wire

233.6 J

-40 °C (-40 °F)

Tin

100 A

150 ms

180

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CUL; PSE; UL

85 °C (185 °F)

Time Lag

0235.800HXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

800 mA

Wire

253 mJ

-55 °C (-67 °F)

35 A

5 s

Bulk

0.197 in (5 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

CSA, CE, UL

125 °C (257 °F)

Fast

02740.002H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

2 mA

Wire

-55 °C (-67 °F)

10 kA

5 s

Bulk

0.25 in (6.35 mm)

125 V

Micro

0.35 in (8.89 mm)

CSA; QPL; UL

85 °C (185 °F)

Very Fast

80411250440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.25 A

Wire

30 J

-40 °C (-40 °F)

Tin

150 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

02720.015H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

15 mA

Wire

1.23 μJ

-55 °C (-67 °F)

10 kA

5 s

Bulk

0.235 in (5.97 mm)

125 V

Micro

0.287 in (7.3 mm)

CSA; QPL; UL

125 °C (257 °F)

Very Fast

02720.050H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

50 mA

Wire

66.6 μJ

-55 °C (-67 °F)

10 kA

5 s

Bulk

0.235 in (5.97 mm)

125 V

Micro

0.287 in (7.3 mm)

CSA; QPL; UL

125 °C (257 °F)

Very Fast

80712000000

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

2 A

Wire

8.8 kJ

-40 °C (-40 °F)

Tin

100 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

300 V

0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm)

0.362 in (9.2 mm)

IEC; CUL; PSE; UL

125 °C (257 °F)

Time Lag

0235007.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

125 V

7 A

Wire

64.815 J

-55 °C (-67 °F)

Tin

10 kA

5 s

Bulk

0.217 in (5.5 mm)

e3

125 V

0.197 x 0.787 in (5 x 20 mm)

0.846 in (21.5 mm)

CE, PSE, UL

125 °C (257 °F)

Fast

0278005.0H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

5 A

Wire

2.21 J

-55 °C (-67 °F)

10 kA

2 s

Bulk

0.235 in (5.97 mm)

125 V

Micro

0.287 in (7.3 mm)

CSA; QPL; UL

125 °C (257 °F)

Very Fast

0215004.MXE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Wire

46.96 J

-55 °C (-67 °F)

Tin

1.5 kA

Bulk

0.228 in (5.8 mm)

e3

250 V

10 µs

0.197 x 0.787 in (5 x 20 mm)

0.886 in (22.5 mm)

CCC; CE; CQC; CSA; CUL; PSE; SEMKO; SEV; UL; VDE

125 °C (257 °F)

Time Lag

38221000430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

10 A

Wire

365 J

-40 °C (-40 °F)

Tin

100 A

150 ms

260

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CUL; PSE; UL

85 °C (185 °F)

Time Lag

023501.6HXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.6 A

Wire

2.025 J

-55 °C (-67 °F)

100 A

5 s

Bulk

0.197 in (5 mm)

250 V

0.197 x 0.787 in (5 x 20 mm)

0.787 in (20 mm)

125 °C (257 °F)

Fast

0215.160MXE

Littelfuse

Electric Fuse

Through Hole Mount

250 V

160 mA

Wire

46.5 mJ

-55 °C (-67 °F)

Tin

1.5 kA

Bulk

0.236 in (6 mm)

e3

250 V

5 µs

0.197 x 0.787 in (5 x 20 mm)

0.886 in (22.5 mm)

CE; CUL; SEMKO; UL

125 °C (257 °F)

Time Lag

38218000430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

8 A

Wire

233.6 J

-40 °C (-40 °F)

Tin

100 A

150 ms

180

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CUL; PSE; UL

85 °C (185 °F)

Time Lag

0278003.0H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

3 A

Wire

759 mJ

-55 °C (-67 °F)

10 kA

2 s

Bulk

0.235 in (5.97 mm)

125 V

Micro

0.287 in (7.3 mm)

CSA; QPL; UL

125 °C (257 °F)

Very Fast

0235.800MXEP

Littelfuse

Electric Fuse

Through Hole Mount

250 V

800 mA

Wire

253 mJ

-55 °C (-67 °F)

Tin

35 A

5 s

Bulk

0.217 in (5.5 mm)

e3

250 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.846 in (21.5 mm)

CE, CSA, UL

125 °C (257 °F)

Fast

0235004.MXEP

Littelfuse

Electric Fuse

Through Hole Mount

125 V

4 A

Wire

17.14 J

-55 °C (-67 °F)

Tin

10 kA

5 s

Bulk

0.217 in (5.5 mm)

e3

125 V

0.197 x 0.787 in (5 x 20 mm)

0.228 x 0.886 in (5.8 x 22.5 mm)

0.846 in (21.5 mm)

CE, CSA, PSE, UL

125 °C (257 °F)

Fast

02780.100H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

100 mA

Wire

385 μJ

-55 °C (-67 °F)

10 kA

5 s

Bulk

0.235 in (5.97 mm)

125 V

Micro

0.287 in (7.3 mm)

CSA; QPL; UL

125 °C (257 °F)

Very Fast

0279004.0H

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

4 A

Wire

1.38 J

-55 °C (-67 °F)

10 kA

2 s

Bulk

0.25 in (6.35 mm)

125 V

Micro

0.35 in (8.89 mm)

CSA; QPL; UL

85 °C (185 °F)

Very Fast

80711000440

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

1 A

Wire

20 kJ

-40 °C (-40 °F)

Tin

100 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

300 V

0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm)

0.362 in (9.2 mm)

IEC; CUL; PSE; UL

125 °C (257 °F)

Time Lag

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.