Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
125 mA |
Wraparound |
2.86 mJ |
-55 °C (-67 °F) |
50 A |
5 s |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
125 V |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CSA; CUL; UL |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
6.3 A |
Wraparound |
9.17 J |
-55 °C (-67 °F) |
Silver |
50 A |
5 s |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e4 |
125 V |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CSA; CUL; PSE; UL |
125 °C (257 °F) |
Very Fast |
||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1.25 A |
Wraparound |
664 mJ |
-55 °C (-67 °F) |
Silver |
50 A |
5 s |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e4 |
125 V |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CE; CSA; CUL; PSE; TUV; UL |
125 °C (257 °F) |
Very Fast |
||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
72 V |
75 V |
12 A |
Wraparound |
260.46 J |
-55 °C (-67 °F) |
Silver |
50 A |
2 ms |
Rated Breaking Capacity at 75 VDC: 100 A |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e4 |
Nano |
0.106 in (2.69 mm) |
CSA; CUL; UL |
125 °C (257 °F) |
Slow |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
420 V |
420 V |
10 A |
Pin Wire |
130 J |
-60 °C (-76 °F) |
Matte Tin |
200 A |
30 ms |
Rated Breaking Capacity at 420 VDC: 300 A |
Bulk |
0.217 in (5.5 mm) |
e3 |
0.197 x 0.787 in (5 x 20 mm) |
0.846 in (21.5 mm) |
CUL; TUV; UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
32 V |
1.25 A |
Wraparound |
51.8 mJ |
-55 °C (-67 °F) |
35 A |
Tape And Reel |
0.063 in (1.6 mm) |
0.032 in (0.813 mm) |
200 ms |
0.063 x 0.032 x 0.012 in (1.6 x 0.813 x 0.305 mm) |
0.012 in (0.305 mm) |
CSA; UL |
90 °C (194 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
60 A |
Tab/Blade |
21.7 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
Bulk |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.315 in (8 mm) |
UL |
125 °C (257 °F) |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
36 V |
20 A |
Wraparound |
65 J |
-55 °C (-67 °F) |
Tin Over Nickel |
200 A |
5 s |
Pre Arcing Time: Open within 5 s at 250% Rated Current, Rated Breaking Capacity at 24 VDC: 250 A |
Tape And Reel |
0.126 in (3.2 mm) |
0.064 in (1.63 mm) |
e3 |
1206 |
0.04 in (1.01 mm) |
CUL; UL |
150 °C (302 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
7.5 A |
Tab/Blade |
53 J |
-40 °C (-40 °F) |
1 kA |
30 ms |
Bulk |
0.429 in (10.9 mm) |
0.15 in (3.8 mm) |
58 V |
Mini |
0.299 in (7.6 mm) |
ISO |
125 °C (257 °F) |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
15 A |
Tab/Blade |
270 J |
-40 °C (-40 °F) |
Silver Over Nickel |
1 kA |
30 ms |
0.429 in (10.9 mm) |
0.15 in (3.8 mm) |
e4 |
58 V |
Mini |
0.429 x 0.15 x 0.346 in (10.9 x 3.8 x 8.8 mm) |
0.346 in (8.8 mm) |
ISO; UL |
125 °C (257 °F) |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
58 V |
15 A |
Tab/Blade |
270 J |
-40 °C (-40 °F) |
Silver |
1 kA |
Rated Breaking Capacity at 58 VDC: 1000 A |
Bulk |
0.429 in (10.9 mm) |
0.14 in (3.55 mm) |
e4 |
0.429 x 0.14 x 0.346 in (10.9 x 3.55 x 8.8 mm) |
0.346 in (8.8 mm) |
125 °C (257 °F) |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
500 mA |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
6 A |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.406 in (10.31 mm) |
0.394 x 1.496 in (10 x 38 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
10 A |
End Cap |
100 kA |
Rated Breaking Capacity at 500 VDC: 50000 A |
0.406 in (10.31 mm) |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Fast |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
170 V |
70 A |
Tab/Blade |
100 kA |
Bulk |
0.563 in (14.3 mm) |
0.877 in (22.28 mm) |
CUL; IEC; TUV; UL |
||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
70 A |
Tab/Blade |
22 kJ |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
22000 |
0.63 in (16 mm) |
0.472 in (12 mm) |
e3 |
32 V |
0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm) |
0.307 in (7.8 mm) |
CUL; ISO; UL |
125 °C (257 °F) |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
48 V |
100 A |
Tab/Blade |
-40 °C (-40 °F) |
600 A |
200 ms |
Bulk |
1.26 in (32 mm) |
0.866 in (22 mm) |
48 V |
1.26 x 0.866 x 0.413 in (32 x 22 x 10.5 mm) |
0.413 in (10.5 mm) |
CUL; UL |
125 °C (257 °F) |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
2 A |
End Cap |
11 J |
100 A |
4 h |
11 |
0.25 in (6.35 mm) |
250 V |
3AB |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; PSE; QPL; UL |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
100 A |
Wraparound |
31 kJ |
-40 °C (-40 °F) |
2 kA |
100 ms |
1.181 in (30 mm) |
1.047 in (26.6 mm) |
Mega |
0.63 in (16 mm) |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
Wraparound |
-40 °C (-40 °F) |
Tin |
2 kA |
100 ms |
1.181 in (30 mm) |
1.047 in (26.6 mm) |
e3 |
Mega |
0.63 in (16 mm) |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
300 V |
300 V |
1.6 A |
Pin Wire |
18.432 J |
-40 °C (-40 °F) |
Tin |
50 A |
20 s |
13.5 |
Bulk |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
e3 |
300 V |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
CUL; PSE; UL; VDE |
85 °C (185 °F) |
Time Lag |
|||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
2.5 A |
Pin Wire |
18.125 J |
-40 °C (-40 °F) |
Matte Tin |
50 A |
1 m |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CSA, UL |
85 °C (185 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
250 mA |
Pin Wire |
170 mJ |
-40 °C (-40 °F) |
Matte Tin |
100 A |
1 m |
0.17 |
Bulk |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
e3 |
125 V |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
UL |
85 °C (185 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1 A |
Pin Wire |
9.63 J |
-40 °C (-40 °F) |
Tin |
130 A |
20 ms |
Ammo Pack; Tape And Reel |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
e3 |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
IEC; PSE; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
2.5 A |
Pin Wire |
61.94 J |
-40 °C (-40 °F) |
Tin |
130 A |
20 ms |
Bulk |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
e3 |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
IEC; PSE; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
500 mA |
End Cap |
10 kA |
2 m |
Bulk |
0.406 in (10.31 mm) |
250 V |
5AG |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Fast |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
1 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
6 A |
End Cap |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
250 V |
40 A |
End Cap |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
0.85 in (21.6 mm) |
600 V |
1.882 in (47.8 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
2 A |
End Cap |
10 kA |
5 s |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
Bulk |
0.406 in (10.31 mm) |
250 V |
0.394 x 1.496 in (10 x 38 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; QPL; UL |
Time Delay |
|||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
1.5 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
0.811 in (20.6 mm) |
Indicator |
0.811 x 5 in (20.6 x 127 mm) |
5 in (127 mm) |
CSA; QPL; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
15 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
0.811 in (20.6 mm) |
Indicator |
0.811 x 5 in (20.6 x 127 mm) |
5 in (127 mm) |
CSA; QPL; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
150 mA |
End Cap |
200 kA |
0.811 in (20.6 mm) |
Indicator |
0.811 x 5 in (20.6 x 127 mm) |
5 in (127 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
3 A |
End Cap |
23.21 J |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
CC |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
3 A |
End Cap |
23.21 J |
200 kA |
12 s |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
6 A |
End Cap |
129.5 J |
Nickel |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; UL |
Time Delay |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
6 A |
End Cap |
129.5 J |
200 kA |
12 s |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
1 A |
End Cap |
8 mJ |
-55 °C (-67 °F) |
100 kA |
4 m |
0.406 in (10.31 mm) |
600 V |
0.394 x 1.496 in (10 x 38 mm) |
1.5 x 1.5 in (38.1 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; IEC; UL |
125 °C (257 °F) |
Fast |
||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
1.4 kA |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
3 in (76.2 mm) |
3.752 in (95.3 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
750 V |
225 A |
Tab/Blade |
91 J |
100 kA |
Rated Breaking Capacity at 750 VDC: 100000 A |
2 in (50.8 mm) |
2 x 3.469 in (50.8 x 88.1 mm) |
3.469 in (88.1 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
||||||||||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
100 A |
Tab/Blade |
12.244 kJ |
20 kA |
8 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
Bulk |
1.5 in (38.1 mm) |
Midget |
3.012 in (76.5 mm) |
CE; IEC; UL |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
1 KV |
250 A |
Tab/Blade |
85.9 kJ |
200 kA |
12 m |
Rated Breaking Capacity at 1000 VDC: 20000 A |
2 in (50.8 mm) |
Midget |
2 x 3.374 in (50.8 x 85.7 mm) |
3.374 in (85.7 mm) |
CE; IEC; UL; VDE |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
1 A |
End Cap |
270 mJ |
30 kA |
4 m |
Bulk |
0.406 in (10.31 mm) |
GPV |
1.5 KV |
0.394 x 3.346 in (10 x 85 mm) |
3.333 in (84.65 mm) |
CUL; TUV; UL |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
8 A |
End Cap |
121 J |
30 kA |
4 m |
Bulk |
0.406 in (10.31 mm) |
GPV |
1.5 KV |
0.394 x 3.346 in (10 x 85 mm) |
0.409 x 3.358 in (10.4 x 85.3 mm) |
3.333 in (84.65 mm) |
CUL; TUV; UL |
Fast |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
7 A |
Wraparound |
10.32 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
5 s |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e3 |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
PSE; UL |
125 °C (257 °F) |
Very Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
7 A |
Wraparound |
10.32 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e3 |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
PSE; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1.5 A |
Wraparound |
3.65 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
100 ms |
Tape And Reel |
0.256 in (6.5 mm) |
0.106 in (2.69 mm) |
e3 |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.