Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
600 V |
5 A |
End Cap |
60 J |
200 kA |
Rated Breaking Capacity at 600 VDC: 100000 A |
0.406 in (10.32 mm) |
0.406 x 1.5 in (10.32 x 38.1 mm) |
1.5 in (38.1 mm) |
UL |
Very Fast |
|||||||||||||||||
Littelfuse |
Electric Fuse |
||||||||||||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
550 A |
Tab/Blade |
44.323 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.2 KV |
900 V |
500 A |
Threaded |
75.315 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 900 VDC: 150000 A |
Bulk |
2.913 in (74 mm) |
2.028 in (51.5 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.2 KV |
900 V |
550 A |
Tab/Blade |
87.328 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 900 VDC: 150000 A |
Bulk |
2.882 in (73.2 mm) |
2.028 in (51.5 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
250 A |
Tab/Blade |
73 kJ |
30 kA |
Bulk |
5.165 in (131.2 mm) |
2.362 in (60 mm) |
NH |
2.362 in (60 mm) |
UL |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
315 mA |
Wraparound |
31.1 mJ |
-55 °C (-67 °F) |
Matte Tin |
50 A |
5 s |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e3 |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
UL |
125 °C (257 °F) |
Very Fast |
|||||||||
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
4 A |
Wraparound |
34.4 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e3 |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
PSE; UL |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
4 A |
Wraparound |
34.4 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
100 ms |
Tape And Reel |
0.256 in (6.5 mm) |
0.106 in (2.69 mm) |
e3 |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
3.5 A |
Wraparound |
26.53 J |
-55 °C (-67 °F) |
Silver |
50 A |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e4 |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
UL |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
3.5 A |
Wraparound |
26.53 J |
-55 °C (-67 °F) |
Matte Tin |
50 A |
100 ms |
Tape And Reel |
0.256 in (6.5 mm) |
0.106 in (2.69 mm) |
e3 |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
125 V |
125 V |
3.15 A |
Wraparound |
1.92 J |
-55 °C (-67 °F) |
Silver |
50 A |
5 s |
Tape And Reel |
0.24 in (6.1 mm) |
0.106 in (2.69 mm) |
e4 |
Nano |
0.24 x 0.106 x 0.106 in (6.1 x 2.69 x 2.69 mm) |
0.106 in (2.69 mm) |
PSE; UL |
125 °C (257 °F) |
Very Fast |
|||||||||
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
125 mA |
Gull Wing |
1.8 mJ |
-55 °C (-67 °F) |
Tin/Lead |
50 A |
2 s |
0.0018 |
Tape And Reel |
0.372 in (9.45 mm) |
0.25 in (6.35 mm) |
e0 |
250 V |
0.372 x 0.25 x 0.165 in (9.45 x 6.35 x 4.19 mm) |
0.165 in (4.19 mm) |
CSA, UL |
125 °C (257 °F) |
Fast |
||||||||||
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
250 mA |
Gull Wing |
14.7 mJ |
-55 °C (-67 °F) |
Tin/Lead |
50 A |
2 s |
0.014 |
Bulk |
0.372 in (9.45 mm) |
0.25 in (6.35 mm) |
e0 |
250 V |
0.372 x 0.25 x 0.165 in (9.45 x 6.35 x 4.19 mm) |
0.165 in (4.19 mm) |
CSA, UL |
125 °C (257 °F) |
Fast |
||||||||||
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
1 A |
Gull Wing |
192 mJ |
-55 °C (-67 °F) |
Tin/Lead |
50 A |
2 s |
0.19 |
Bulk |
0.372 in (9.45 mm) |
0.25 in (6.35 mm) |
e0 |
250 V |
0.372 x 0.25 x 0.165 in (9.45 x 6.35 x 4.19 mm) |
0.165 in (4.19 mm) |
CSA, UL |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
350 V |
2 A |
Pin Wire |
30 J |
-55 °C (-67 °F) |
Tin |
100 A |
Bulk |
0.185 in (4.7 mm) |
e3 |
0.185 x 0.57 in (4.7 x 14.48 mm) |
0.57 in (14.48 mm) |
CE; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
350 V |
2 A |
Pin Wire |
30 J |
-55 °C (-67 °F) |
Matte Tin |
100 A |
3 s |
30 |
Bulk |
0.189 in (4.8 mm) |
e3 |
350 V |
2AG |
0.185 x 0.57 in (4.7 x 14.48 mm) |
0.587 in (14.9 mm) |
CE; CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
630 mA |
End Cap |
635 mJ |
-55 °C (-67 °F) |
1.5 kA |
Pre Arcing Time: Open within 5 ms at 1000% Rated Current |
Bulk |
0.205 in (5.2 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; CUL; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||||||
|
Littelfuse |
Electric Fuse |
1 A |
End Cap |
-55 °C (-67 °F) |
Tin |
1.5 kA |
1.52 |
0.205 in (5.2 mm) |
Supplemental |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI, CCC, CE, CSA, PSE, UL, VDE |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
4 A |
End Cap |
46.96 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
10 ms |
46.96 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
8 A |
End Cap |
209.88 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
Bulk |
0.205 in (5.2 mm) |
e3 |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CQC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
333.565 J |
-55 °C (-67 °F) |
1.5 kA |
10 ms |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; CUL; KC; PSE; SEMKO; SEV; TUV; VDE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
50 mA |
Pin Wire |
190 μJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
20 ms |
0.0001 |
Bulk |
0.236 in (6 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.236 x 0.886 in (6 x 22.5 mm) |
0.886 in (22.5 mm) |
CCC; CE; CSA; IEC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 mA |
End Cap |
5.46 mJ |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
0.0054 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 mA |
End Cap |
5.46 mJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
20 ms |
0.0054 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
200 mA |
Pin Wire |
4.39 mJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
20 ms |
0.0043 |
Bulk |
0.236 in (6 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.236 x 0.886 in (6 x 22.5 mm) |
0.886 in (22.5 mm) |
CCC; CE; CSA; IEC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
800 mA |
End Cap |
285 mJ |
-55 °C (-67 °F) |
Tin |
1.5 kA |
0.285 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1 A |
End Cap |
180 mJ |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
0.18 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
4 A |
End Cap |
14.995 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
14.995 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
8 A |
Wire |
64.315 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
10 ms |
Bulk |
0.228 in (5.8 mm) |
e3 |
0.197 x 0.787 in (5 x 20 mm) |
0.886 in (22.5 mm) |
CE, CSA, PSE, UL, VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
8 A |
Pin Wire |
64.315 J |
-55 °C (-67 °F) |
Matte Tin |
1.5 kA |
30 ms |
64.315 |
Bulk |
0.228 in (5.8 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.886 in (22.5 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; UL |
125 °C (257 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
154.34 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
154.34 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
6.3 A |
Pin Wire |
56.43 J |
-55 °C (-67 °F) |
1.5 kA |
Bulk |
0.205 in (5.2 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; CQC; IEC; KC; PSE; VDE; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1.25 A |
End Cap |
180 mJ |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
0.48 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
1.25 A |
End Cap |
180 mJ |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
20 ms |
0.48 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
12.5 A |
End Cap |
235 J |
-55 °C (-67 °F) |
Tin |
1.5 kA |
175 |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; PSE; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
12.5 A |
End Cap |
235 J |
-55 °C (-67 °F) |
Nickel |
1.5 kA |
30 ms |
175 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CE; CSA; IEC; PSE; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
32 mA |
End Cap |
150 μJ |
-55 °C (-67 °F) |
Tin |
35 A |
3 ms |
Bulk |
0.205 in (5.2 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; SEMKO; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
160 mA |
End Cap |
10 mJ |
-55 °C (-67 °F) |
35 A |
10 ms |
Bulk |
0.205 in (5.2 mm) |
0.197 x 0.787 in (5 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; SEMKO; UL; VDE |
125 °C (257 °F) |
Very Fast |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
160 mA |
Pin Wire |
10 mJ |
-55 °C (-67 °F) |
35 A |
10 ms |
Pre Arcing Time: Open within 10 ms at 400% Rated Current |
Bulk |
0.22 in (5.6 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.846 in (21.5 mm) |
CCC; CE; CSA; CUL; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Fast |
||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.6 A |
Pin Wire |
4.615 J |
-55 °C (-67 °F) |
Tin |
35 A |
10 ms |
4.615 |
Bulk |
0.217 in (5.5 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.846 in (21.5 mm) |
CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Very Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
63 mA |
End Cap |
46 mJ |
-55 °C (-67 °F) |
35 A |
Pre Arcing Time: Open within 10 ms at 1000% Rated Current |
Bulk |
0.205 in (5.2 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
125 mA |
Pin Wire |
146.5 mJ |
-55 °C (-67 °F) |
Tin |
35 A |
20 ms |
0.1465 |
Bulk |
0.217 in (5.5 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.846 in (21.5 mm) |
CCC; CE; CSA; KC; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
400 mA |
End Cap |
1.325 J |
-55 °C (-67 °F) |
Nickel |
35 A |
20 ms |
1.325 |
Bulk |
0.205 in (5.2 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; KC; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
500 mA |
End Cap |
2.825 J |
-55 °C (-67 °F) |
Tin |
35 A |
2.825 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
CCC; CE; CSA; IEC; KC; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
500 mA |
Pin Wire |
2.825 J |
-55 °C (-67 °F) |
Matte Tin |
35 A |
20 ms |
2.825 |
Bulk |
0.217 in (5.5 mm) |
e3 |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.228 x 0.886 in (5.8 x 22.5 mm) |
0.846 in (21.5 mm) |
CCC; CE; CSA; KC; SEMKO; SEV; UL; VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
500 mA |
End Cap |
2.825 J |
-55 °C (-67 °F) |
Nickel |
35 A |
20 ms |
2.825 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI, CCC, CE, CSA, KC, SEMKO, UL, VDE |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
6.3 A |
End Cap |
198.5 J |
-55 °C (-67 °F) |
Nickel |
63 A |
20 ms |
198.5 |
Bulk |
0.205 in (5.2 mm) |
Supplemental |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.205 x 0.787 in (5.2 x 20 mm) |
0.787 in (20 mm) |
BSI; CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE |
125 °C (257 °F) |
Time Lag |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.