Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
6.3 A |
Pin Wire |
138.915 J |
-40 °C (-40 °F) |
Matte Tin |
50 A |
20 ms |
105 |
Ammo Pack; Tape |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CCC; CE; CUL; KC; UL; VDE |
85 °C (185 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
63 mA |
Pin Wire |
200 μJ |
-40 °C (-40 °F) |
Tin |
50 A |
5 s |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CSA; CUL; UL |
85 °C (185 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
4 A |
Pin Wire |
3.5 J |
-40 °C (-40 °F) |
Matte Tin |
50 A |
5 s |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CSA; CUL; UL |
85 °C (185 °F) |
Very Fast |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
400 mA |
Pin Wire |
552 mJ |
-40 °C (-40 °F) |
Tin |
50 A |
1 m |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CSA, UL |
85 °C (185 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.25 A |
Pin Wire |
4.453 J |
-40 °C (-40 °F) |
Matte Tin |
50 A |
1 m |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CSA, UL |
85 °C (185 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
6.3 A |
Pin Wire |
144.869 J |
-40 °C (-40 °F) |
Matte Tin |
50 A |
1 m |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CSA, UL |
85 °C (185 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.25 A |
Wire |
6.88 J |
-40 °C (-40 °F) |
Tin |
100 A |
150 ms |
4.5 |
Ammo Pack |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CCC; CE; CUL; PSE; UL; VDE |
85 °C (185 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
5 A |
Wire |
121.25 J |
-40 °C (-40 °F) |
Tin |
100 A |
150 ms |
90 |
Bulk |
0.335 in (8.5 mm) |
e3 |
250 V |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CCC; CE; CUL; PSE; UL; VDE |
85 °C (185 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
320 V |
2.5 A |
Pin Wire |
29.69 J |
-40 °C (-40 °F) |
50 A |
20 ms |
Ammo Pack; Tape |
0.335 in (8.5 mm) |
TR5 |
0.335 x 0.315 in (8.5 x 8 mm) |
0.315 in (8 mm) |
CE; CUL; PSE; UL |
85 °C (185 °F) |
Time Lag |
|||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
65 V |
65 V |
200 mA |
Pin Wire |
20 mJ |
-40 °C (-40 °F) |
50 A |
2 s |
Rated Breaking Capacity at 65 VDC: 50 A |
Ammo Pack; Tape And Reel |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
65 V |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
CUL; UKCA; UL |
125 °C (257 °F) |
Fast |
|||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
500 mA |
Pin Wire |
580 mJ |
-40 °C (-40 °F) |
Matte Tin |
100 A |
1 m |
0.58 |
Ammo Pack; Tape And Reel |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
e3 |
125 V |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
UL |
85 °C (185 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
630 mA |
Pin Wire |
750 mJ |
-40 °C (-40 °F) |
Tin |
100 A |
1 m |
0.75 |
Ammo Pack; Tape And Reel |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
e3 |
125 V |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
UL |
85 °C (185 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
630 mA |
Pin Wire |
750 mJ |
-40 °C (-40 °F) |
Tin |
100 A |
1 m |
0.75 |
Bulk |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
e3 |
125 V |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
UL |
85 °C (185 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
2.5 A |
Pin Wire |
14 J |
-40 °C (-40 °F) |
Matte Tin |
100 A |
1 m |
14 |
Ammo Pack; Tape And Reel |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
e3 |
125 V |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
PSE; UL |
85 °C (185 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
6.3 A |
Pin Wire |
100 J |
-40 °C (-40 °F) |
Tin |
100 A |
1 m |
100 |
Ammo Pack; Tape And Reel |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
e3 |
125 V |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
UL |
85 °C (185 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
1.6 A |
Pin Wire |
21.75 J |
-40 °C (-40 °F) |
Tin |
130 A |
20 ms |
Ammo Pack; Tape And Reel |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
e3 |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
IEC; PSE; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
6.3 A |
Pin Wire |
318.71 J |
-40 °C (-40 °F) |
Matte Tin |
130 A |
20 ms |
Ammo Pack; Tape And Reel |
0.335 in (8.5 mm) |
0.157 in (4 mm) |
e3 |
TE5 |
0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm) |
0.315 in (8 mm) |
IEC; UL; VDE |
125 °C (257 °F) |
Time Lag |
||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
250 V |
500 mA |
Wraparound |
430 mJ |
-40 °C (-40 °F) |
Tin |
150 A |
10 ms |
0.43 |
Tape And Reel |
0.413 in (10.5 mm) |
0.177 in (4.5 mm) |
e3 |
250 V |
Nano |
0.177 x 0.177 x 0.413 in (4.5 x 4.5 x 10.5 mm) |
0.177 in (4.5 mm) |
CUL; UL |
85 °C (185 °F) |
Time Lag |
|||||||
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
250 V |
500 mA |
Wraparound |
430 mJ |
-40 °C (-40 °F) |
Tin |
150 A |
10 ms |
0.43 |
Tape And Reel |
0.413 in (10.5 mm) |
0.177 in (4.5 mm) |
e3 |
250 V |
Nano |
0.177 x 0.177 x 0.413 in (4.5 x 4.5 x 10.5 mm) |
0.177 in (4.5 mm) |
CUL; UL |
85 °C (185 °F) |
Time Lag |
||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
70 V |
125 A |
Tab/Blade |
51.3 kJ |
-40 °C (-40 °F) |
2.5 kA |
70 ms |
0.63 in (16 mm) |
0.496 in (12.6 mm) |
0.323 in (8.2 mm) |
UL |
125 °C (257 °F) |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
300 V |
300 V |
4 A |
Wire |
36.8 kJ |
-40 °C (-40 °F) |
Matte Tin |
100 A |
1 s |
Ammo Pack |
0.488 in (12.4 mm) |
0.252 in (6.4 mm) |
e3 |
300 V |
0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm) |
0.362 in (9.2 mm) |
IEC; CUL; PSE; UL |
125 °C (257 °F) |
Time Lag |
|||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
12 A |
End Cap |
200 kA |
Rated Breaking Capacity at 500 VDC: 20000 A |
Bulk |
0.406 in (10.3 mm) |
600 V |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
500 V |
15 A |
End Cap |
0.406 in (10.3 mm) |
CC |
1.5 in (38.1 mm) |
UL |
Time Delay |
|||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
5 A |
End Cap |
10 kA |
12 s |
Pre Arcing Time: Open within 12 s at 200% Rated Current |
Bulk |
0.406 in (10.31 mm) |
250 V |
0.394 x 1.496 in (10 x 38 mm) |
0.406 x 1.5 in (10.3 x 38.1 mm) |
1.5 in (38.1 mm) |
CE; CSA; QPL; UL |
Time Delay |
|||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
10 A |
End Cap |
10 kA |
0.406 in (10.31 mm) |
0.406 x 1.5 in (10.31 x 38.1 mm) |
1.5 in (38.1 mm) |
CSA; QPL; UL |
Slow |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
500 mA |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
0.563 in (14.3 mm) |
0.563 x 2 in (14.3 x 50.8 mm) |
2 in (50.8 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
35 A |
End Cap |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
0.815 in (20.7 mm) |
Indicator |
3 in (76.2 mm) |
CSA; UL |
Time Delay |
||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
110 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
1.535 in (39 mm) |
7.126 in (181 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
125 V |
500 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
Bulk |
2.543 in (64.6 mm) |
10.374 in (263.5 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
5 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.815 in (20.7 mm) |
Indicator |
5 in (127 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
20 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.815 in (20.7 mm) |
Indicator |
5 in (127 mm) |
CSA; UL |
Time Delay |
|||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
90 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.283 in (32.6 mm) |
7.874 in (200 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
8 A |
End Cap |
200 kA |
0.811 in (20.6 mm) |
Indicator |
0.811 x 5 in (20.6 x 127 mm) |
5 in (127 mm) |
CSA; UL |
Time Delay |
||||||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
10 A |
Pin Wire |
Tin Lead |
0.102 in (2.59 mm) |
e0 |
0.102 x 0.311 in (2.59 x 7.9 mm) |
0.311 in (7.9 mm) |
MIL-PRF-23419 |
||||||||||||||||||||
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
125 V |
10 A |
Pin Wire |
25.5 J |
-55 °C (-67 °F) |
50 A |
Rated Breaking Capacity at 125 VDC: 300 A |
0.103 in (2.61 mm) |
0.103 x 0.28 in (2.61 x 7.11 mm) |
0.28 in (7.11 mm) |
CSA; MIL-PRF-23419/10; QPL; TUV; UL |
125 °C (257 °F) |
Very Fast |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
85 V |
30 A |
Wraparound |
-10 °C (14 °F) |
80 A |
Tape And Reel, 13 inch |
0.374 in (9.5 mm) |
0.197 in (5 mm) |
0.079 in (2 mm) |
CUL; TUV; UL |
65 °C (149 °F) |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
80 V |
60 A |
Wraparound |
-10 °C (14 °F) |
160 A |
Tape And Reel, 13 inch |
0.374 in (9.5 mm) |
0.197 in (5 mm) |
0.079 in (2 mm) |
65 °C (149 °F) |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
160 V |
50 A |
End Cap |
200 kA |
Rated Breaking Capacity at 160 VDC: 20000 A |
0.563 in (14.3 mm) |
300 V |
0.874 in (22.2 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
70 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
0.811 in (20.6 mm) |
0.811 x 0.843 in (20.6 x 21.4 mm) |
2.157 in (54.8 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
70 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
0.811 in (20.6 mm) |
300 V |
2.157 in (54.8 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
175 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.063 in (27 mm) |
300 V |
2.437 in (61.9 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
700 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
2.063 in (52.4 mm) |
300 V |
3.374 in (85.7 mm) |
CSE; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
60 A |
End Cap |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
0.992 in (25.2 mm) |
600 V |
1.563 in (39.7 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
225 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
1.594 in (40.5 mm) |
600 V |
1.713 in (43.5 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
600 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
2.063 in (52.4 mm) |
600 V |
1.764 in (44.8 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
300 V |
700 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
Bulk |
2.5 in (63.5 mm) |
600 V |
1.858 in (47.2 mm) |
CE; CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
20 A |
End Cap |
200 kA |
Bulk |
0.811 in (20.6 mm) |
0.811 x 2.252 in (20.6 x 57.2 mm) |
2.252 in (57.2 mm) |
CE; CSA; QPL; UL |
Fast |
||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
150 A |
Tab/Blade |
200 kA |
Bulk |
1.5 in (38.1 mm) |
1.5 x 3 in (38.1 x 76.2 mm) |
3 in (76.2 mm) |
CE; CSA; QPL; UL |
Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.