Part | RoHS | Manufacturer | Connector Accessory Type | Connector Side-1 | Connector Side-2 | Rated Voltage | Rated Current | Shielding | Approvals (V) | Cross Section Area | Finish Thickness | Conductor Material | Construction | Minimum Wire Size | Jacket Material | Terminal Type | Resistance | Conductor Finish | MIL Conformity | Maximum Wire Size | Insulator Material | Maximum Operating Temperature | DIN Conformity | Application | Cable Types | IEC Conformity | Minimum Operating Temperature | Wire Gauge (AWG) | Design | Diameter | No. of Conductors | Mounting Style | Additional Features | Material | Mounting Option-2 | Length | Mounting Option-1 | Wire & Cable Name | Stranding | Rated DC Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; EAC |
2.5 mm2 |
BARE COPPER |
STRANDED |
NO |
PVC |
80 Cel |
YES |
SWITCH CABINET CONSTRUCTION, MEASUREMENT SET-UPS IN LAB |
NO |
-15 Cel |
14 |
3.8 mm |
1 |
STANDARDS: DIN VDE 0250; DIN VDE 0285-525-1; DIN EN 50525-1 |
FLEXIBLE CORD AND FIXTURE WIRE |
320X0.1 |
||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; EAC |
2.5 mm2 |
BARE COPPER |
STRANDED |
NO |
PVC |
80 Cel |
YES |
SWITCH CABINET CONSTRUCTION, MEASUREMENT SET-UPS IN LAB |
NO |
-15 Cel |
14 |
3.8 mm |
1 |
STANDARDS: DIN VDE 0250; DIN VDE 0285-525-1; DIN EN 50525-1 |
FLEXIBLE CORD AND FIXTURE WIRE |
320X0.1 |
||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
1 mm2 |
BARE COPPER |
POLYURETHANE |
NO |
RUBBER |
70 Cel |
NO |
MACHINE CONSTRUCTION, BUILDING INDUSTRY ETC. |
NO |
-25 Cel |
17 |
11.1 mm |
7 |
FLEXIBLE CORD AND FIXTURE WIRE |
|||||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; EAC |
1.5 mm2 |
BARE COPPER |
STRANDED |
NO |
PVC |
80 Cel |
YES |
SWITCH CABINET CONSTRUCTION, MEASUREMENT SET-UPS IN LAB |
NO |
-15 Cel |
16 |
3.5 mm |
1 |
STANDARDS: DIN VDE 0250; DIN VDE 0285-525-1; DIN EN 50525-1 |
FLEXIBLE CORD AND FIXTURE WIRE |
192X0.1 |
||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; DIN; EAC |
1.5 mm2 |
BARE COPPER |
STRANDED |
POLYURETHANE |
NO |
THERMOPLASTIC ELASTOMER |
90 Cel |
YES |
ROBUST, FLEXIBLE CABLE FOR USE IN DRY, DAMP AND WET ROOMS |
NO |
-40 Cel |
16 |
13 mm |
7 |
STANDARDS: DIN VDE 0285-525-2-21; DIN EN 50525-2-21 |
COMMUNICATION AND CONTROL CABLE |
||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; EAC |
4 mm2 |
BARE COPPER |
STRANDED |
NO |
PVC |
80 Cel |
YES |
SWITCH CABINET CONSTRUCTION, MEASUREMENT SET-UPS IN LAB |
NO |
-15 Cel |
12 |
4.9 mm |
1 |
STANDARDS: DIN VDE 0250; DIN VDE 0285-525-1; DIN EN 50525-1 |
FLEXIBLE CORD AND FIXTURE WIRE |
512X0.1 |
||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; CSA; EAC; UL |
1.5 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
90 Cel |
JUMPER WIRE PRIMARILY DESIGNED FOR EXPORTES, MACHINE TOOLS |
-40 Cel |
16 |
3.05 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
450 V |
NO |
CE; EAC; EN; HAR |
1.5 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
80 Cel |
LAYING IN TUBES, EXPOSED OR BURIED IN PLASTER |
-40 Cel |
3.4 mm |
1 |
POWER AND CONTROL CABLE |
|||||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
450 V |
COPPER ALLOY |
TIN |
28 AWG |
150 Cel |
-65 Cel |
28 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
450 V |
NO |
CE; EAC; EN; HAR |
6 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
80 Cel |
LAYING IN TUBES, EXPOSED OR BURIED IN PLASTER |
-40 Cel |
5.3 mm |
1 |
POWER AND CONTROL CABLE |
|||||||||||||||||||||||||
|
TE Connectivity |
WIRE AND CABLE |
450 V |
COPPER ALLOY |
SILVER |
24 AWG |
200 Cel |
SPEC 55 |
-65 Cel |
24 |
FLEXIBLE CORD AND FIXTURE WIRE |
|||||||||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; CSA; EAC; UL |
35 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
90 Cel |
JUMPER WIRE PRIMARILY DESIGNED FOR EXPORTES, MACHINE TOOLS |
-40 Cel |
2 |
10.8 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; EAC |
4 mm2 |
BARE COPPER |
STRANDED |
NO |
PVC |
80 Cel |
YES |
SWITCH CABINET CONSTRUCTION, MEASUREMENT SET-UPS IN LAB |
NO |
-15 Cel |
12 |
4.9 mm |
1 |
STANDARDS: DIN VDE 0250; DIN VDE 0285-525-1; DIN EN 50525-1 |
FLEXIBLE CORD AND FIXTURE WIRE |
512X0.1 |
||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
450 V |
NO |
CE; EN; HAR; IEC; VDE |
1.5 mm2 |
BARE COPPER |
STRANDED |
RUBBER |
RUBBER |
60 Cel |
MEDIUM, MECHANICAL STRESS AND INDUSTRIAL AND AGRICULTURAL |
-25 Cel |
11.9 mm |
3 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; DIN; EAC; VDE |
6 mm2 |
BARE COPPER |
NO |
POLYVINYLCHLORIDE |
90 Cel |
NO |
NO |
5 Cel |
9 |
5.3 mm |
1 |
POWER CABLE |
|||||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
450 V |
NO |
CE; EAC; EN; HAR |
1.5 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
80 Cel |
LAYING IN TUBES, EXPOSED OR BURIED IN PLASTER |
-40 Cel |
3.4 mm |
1 |
POWER AND CONTROL CABLE |
|||||||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
450 V |
NO |
CE; EAC; EN; HAR |
4 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
80 Cel |
LAYING IN TUBES, EXPOSED OR BURIED IN PLASTER |
-40 Cel |
4.8 mm |
1 |
POWER AND CONTROL CABLE |
|||||||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
450 V |
NO |
CE; EAC; EN; HAR |
6 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
80 Cel |
LAYING IN TUBES, EXPOSED OR BURIED IN PLASTER |
-40 Cel |
5.3 mm |
1 |
POWER AND CONTROL CABLE |
|||||||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; EAC |
1.5 mm2 |
BARE COPPER |
STRANDED |
NO |
PVC |
80 Cel |
YES |
SWITCH CABINET CONSTRUCTION, MEASUREMENT SET-UPS IN LAB |
NO |
-15 Cel |
16 |
3.5 mm |
1 |
STANDARDS: DIN VDE 0250; DIN VDE 0285-525-1; DIN EN 50525-1 |
FLEXIBLE CORD AND FIXTURE WIRE |
192X0.1 |
||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; EAC |
4 mm2 |
BARE COPPER |
STRANDED |
NO |
PVC |
80 Cel |
YES |
SWITCH CABINET CONSTRUCTION, MEASUREMENT SET-UPS IN LAB |
NO |
-15 Cel |
12 |
4.9 mm |
1 |
STANDARDS: DIN VDE 0250; DIN VDE 0285-525-1; DIN EN 50525-1 |
FLEXIBLE CORD AND FIXTURE WIRE |
512X0.1 |
||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; DIN; EAC; VDE |
1.5 mm2 |
BARE COPPER |
NO |
POLYVINYLCHLORIDE |
90 Cel |
NO |
NO |
5 Cel |
15 |
3.4 mm |
1 |
POWER CABLE |
|||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
BS; CE; DIN; IEC; VDE |
185 mm2 |
BARE COPPER |
STRANDED |
ETHYLENE PROPYLENE RUBBER |
NO |
ETHYLENE PROPYLENE RUBBER |
80 Cel |
NO |
NO |
-40 Cel |
350 |
27.6 mm |
1 |
CONTROL CABLE/COMMAND CABLE |
|||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
BS; CE; DIN; IEC; VDE |
2.5 mm2 |
BARE COPPER |
STRANDED |
ETHYLENE PROPYLENE RUBBER |
NO |
ETHYLENE PROPYLENE RUBBER |
80 Cel |
NO |
NO |
-40 Cel |
14 |
13.3 mm |
5 |
CONTROL CABLE/COMMAND CABLE |
|||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
450 V |
NO |
CE; EAC; EN; HAR |
2.5 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
80 Cel |
LAYING IN TUBES, EXPOSED OR BURIED IN PLASTER |
-40 Cel |
4.1 mm |
1 |
POWER AND CONTROL CABLE |
|||||||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
450 V |
NO |
CE; EAC; EN; HAR |
2.5 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
80 Cel |
LAYING IN TUBES, EXPOSED OR BURIED IN PLASTER |
-40 Cel |
4.1 mm |
1 |
POWER AND CONTROL CABLE |
|||||||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
450 V |
NO |
CE; EAC; EN; HAR |
6 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
80 Cel |
LAYING IN TUBES, EXPOSED OR BURIED IN PLASTER |
-40 Cel |
5.3 mm |
1 |
POWER AND CONTROL CABLE |
|||||||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
450 V |
NO |
CE; EAC; EN; HAR |
10 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
80 Cel |
LAYING IN TUBES, EXPOSED OR BURIED IN PLASTER |
-40 Cel |
6.8 mm |
1 |
POWER AND CONTROL CABLE |
|||||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; CSA; EAC; UL |
6 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
90 Cel |
JUMPER WIRE PRIMARILY DESIGNED FOR EXPORTES, MACHINE TOOLS |
-40 Cel |
10 |
4.8 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; EAC |
70 mm2 |
BARE COPPER |
STRANDED |
NO |
PVC |
80 Cel |
YES |
SWITCH CABINET CONSTRUCTION, MEASUREMENT SET-UPS IN LAB |
NO |
-15 Cel |
00 |
15.5 mm |
1 |
STANDARDS: DIN VDE 0250; DIN VDE 0285-525-1; DIN EN 50525-1 |
FLEXIBLE CORD AND FIXTURE WIRE |
8967X0.1 |
||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; EAC |
4 mm2 |
BARE COPPER |
STRANDED |
NO |
PVC |
80 Cel |
YES |
SWITCH CABINET CONSTRUCTION, MEASUREMENT SET-UPS IN LAB |
NO |
-15 Cel |
12 |
4.9 mm |
1 |
STANDARDS: DIN VDE 0250; DIN VDE 0285-525-1; DIN EN 50525-1 |
FLEXIBLE CORD AND FIXTURE WIRE |
512X0.1 |
||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
BS; CE; DIN; IEC; VDE |
1.5 mm2 |
BARE COPPER |
STRANDED |
ETHYLENE PROPYLENE RUBBER |
NO |
ETHYLENE PROPYLENE RUBBER |
80 Cel |
NO |
NO |
-40 Cel |
16 |
6 mm |
1 |
CONTROL CABLE/COMMAND CABLE |
|||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
BS; CE; DIN; IEC; VDE |
4 mm2 |
BARE COPPER |
STRANDED |
ETHYLENE PROPYLENE RUBBER |
NO |
ETHYLENE PROPYLENE RUBBER |
80 Cel |
NO |
NO |
-40 Cel |
12 |
7.2 mm |
1 |
CONTROL CABLE/COMMAND CABLE |
|||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
BS; CE; DIN; IEC; VDE |
16 mm2 |
BARE COPPER |
STRANDED |
ETHYLENE PROPYLENE RUBBER |
NO |
ETHYLENE PROPYLENE RUBBER |
80 Cel |
NO |
NO |
-40 Cel |
6 |
11.5 mm |
1 |
CONTROL CABLE/COMMAND CABLE |
|||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
BS; CE; DIN; IEC; VDE |
35 mm2 |
BARE COPPER |
STRANDED |
ETHYLENE PROPYLENE RUBBER |
NO |
ETHYLENE PROPYLENE RUBBER |
80 Cel |
NO |
NO |
-40 Cel |
2 |
15 mm |
1 |
CONTROL CABLE/COMMAND CABLE |
|||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
BS; CE; DIN; IEC; VDE |
50 mm2 |
BARE COPPER |
STRANDED |
ETHYLENE PROPYLENE RUBBER |
NO |
ETHYLENE PROPYLENE RUBBER |
80 Cel |
NO |
NO |
-40 Cel |
1 |
17.5 mm |
1 |
CONTROL CABLE/COMMAND CABLE |
|||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
BS; CE; DIN; IEC; VDE |
70 mm2 |
BARE COPPER |
STRANDED |
ETHYLENE PROPYLENE RUBBER |
NO |
ETHYLENE PROPYLENE RUBBER |
80 Cel |
NO |
NO |
-40 Cel |
00 |
20 mm |
1 |
CONTROL CABLE/COMMAND CABLE |
|||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
BS; CE; DIN; IEC; VDE |
1.5 mm2 |
BARE COPPER |
STRANDED |
ETHYLENE PROPYLENE RUBBER |
NO |
ETHYLENE PROPYLENE RUBBER |
80 Cel |
NO |
NO |
-40 Cel |
16 |
8.5 mm |
2 |
CONTROL CABLE/COMMAND CABLE |
|||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
BS; CE; DIN; IEC; VDE |
2.5 mm2 |
BARE COPPER |
STRANDED |
ETHYLENE PROPYLENE RUBBER |
NO |
ETHYLENE PROPYLENE RUBBER |
80 Cel |
NO |
NO |
-40 Cel |
14 |
10.2 mm |
2 |
CONTROL CABLE/COMMAND CABLE |
|||||||||||||||||||||
|
Lapp Group Pvt |
WIRE AND CABLE |
450 V |
NO |
CE; EAC; EN; HAR |
2.5 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
80 Cel |
LAYING IN TUBES, EXPOSED OR BURIED IN PLASTER |
-40 Cel |
4.1 mm |
1 |
POWER AND CONTROL CABLE |
|||||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; CSA; EAC; UL |
2.5 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
90 Cel |
JUMPER WIRE PRIMARILY DESIGNED FOR EXPORTES, MACHINE TOOLS |
-40 Cel |
14 |
3.6 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; CSA; EAC; UL |
35 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
90 Cel |
JUMPER WIRE PRIMARILY DESIGNED FOR EXPORTES, MACHINE TOOLS |
-40 Cel |
2 |
10.8 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; CSA; EAC; UL |
120 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
90 Cel |
JUMPER WIRE PRIMARILY DESIGNED FOR EXPORTES, MACHINE TOOLS |
-40 Cel |
19.5 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
|||||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; EAC |
1.5 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
POLYVINYL CHLORIDE |
80 Cel |
FLEXIBLE USE FOR MEDIUM MECHANICAL, STRESSES WITH FREE MOVES |
-40 Cel |
16 |
9.6 mm |
5 |
FLEXIBLE CORD AND FIXTURE WIRE |
|||||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; DIN; EAC |
1.5 mm2 |
BARE COPPER |
STRANDED |
POLYURETHANE |
NO |
THERMOPLASTIC ELASTOMER |
90 Cel |
YES |
ROBUST, FLEXIBLE CABLE FOR USE IN DRY, DAMP AND WET ROOMS |
NO |
-40 Cel |
16 |
12 mm |
6 |
STANDARDS: DIN VDE 0285-525-2-21; DIN EN 50525-2-21 |
COMMUNICATION AND CONTROL CABLE |
||||||||||||||||||||
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; DIN; EAC |
1.5 mm2 |
BARE COPPER |
STRANDED |
POLYURETHANE |
NO |
THERMOPLASTIC ELASTOMER |
90 Cel |
YES |
ROBUST, FLEXIBLE CABLE FOR USE IN DRY, DAMP AND WET ROOMS |
NO |
-40 Cel |
16 |
12 mm |
6 |
STANDARDS: DIN VDE 0285-525-2-21; DIN EN 50525-2-21 |
COMMUNICATION AND CONTROL CABLE |
||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; DIN; EAC; VDE |
35 mm2 |
BARE COPPER |
NO |
POLYVINYLCHLORIDE |
90 Cel |
NO |
NO |
5 Cel |
2 |
11.7 mm |
1 |
POWER CABLE |
|||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; CSA; EAC; UL |
6 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
90 Cel |
JUMPER WIRE PRIMARILY DESIGNED FOR EXPORTES, MACHINE TOOLS |
-40 Cel |
10 |
4.8 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
||||||||||||||||||||||||
|
Helukabel |
WIRE AND CABLE |
450 V |
NO |
CE; CSA; EAC; UL |
10 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
90 Cel |
JUMPER WIRE PRIMARILY DESIGNED FOR EXPORTES, MACHINE TOOLS |
-40 Cel |
8 |
6.4 mm |
1 |
FLEXIBLE CORD AND FIXTURE WIRE |
Electrical wires and cables are conductive materials that are used to transmit electrical power and signals from one location to another. They are an essential component of any electrical system, ranging from small electronic devices to large industrial installations.
Electrical wires are typically made of a conductive material, such as copper or aluminum, that is coated in an insulating material to prevent electrical leakage or short-circuits. They are available in various gauges and thicknesses to handle different levels of electrical current and resistance.
Cables, on the other hand, are bundles of two or more electrical wires that are wrapped in an outer jacket for protection and insulation. They are designed for specific purposes, such as transmitting high-speed data, audio, or video signals, and can be shielded or unshielded to reduce electromagnetic interference.
Both electrical wires and cables are critical components of modern electrical systems and are used in a wide range of applications, including residential and commercial buildings, automotive and aerospace industries, telecommunications, and more.