Part | RoHS | Manufacturer | Connector Type | Option | Reliability | Contact Gender | Dielectric Withstanding Voltage (V) | No. of Connectors | Panel Mount | Mating Contact Pitch (inch) | Body Length | Insulation Resistance | Mixed Contacts | Rated Current - Power | EMI Shielded | Filter Feature | Body Width | Termination Contact Finish | Body Depth | Rated Voltage | MIL Conformity | Insulator Material | No. of Rows Loaded | Maximum Operating Temperature (Cel) | DIN Conformance | Board Mounting Option | PCB Contact Row Spacing (mm) | Contact Design | IEC Conformity | Minimum Operating Temperature | Empty Shell | Shell Finish | Plating Thickness (inch) | No. of Ports | No. of PCB Rows | Contact Material | UL Flammability Code | Mating Contact Finish | Polarization Key | Additional Features | Rated Current - Signal | Reference Standard | Insulator Color | Polarization | Total No. of Contacts | Contact Arrangement | Minimum Wire Size | Durability | Mating Contact Row Spacing (inch) | Mounting Type | Maximum Wire Size | Characteristic Impedance | Sub-Category | Shell Material | Terminal Pitch (mm) | Cable Types | Mating Info. | PCB Contact Pattern | Mains Connector Rating | Contact Sizes | Termination Type | Minimum Withdrawal Force (N) | Manufacturer Series | Contact Resistance | Body or Shell Style | Mounting Style | Minimum Insulation Diameter | Contact Style | JESD-609 Code | Maximum Insertion Force (N) | Mounting Option-2 | Terminal Length | Mounting Option-1 | Maximum Operating Frequency | Contact Pattern | Shell Size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.931 inch |
NO |
NO |
NO |
.872 inch |
NOT APPLICABLE |
.848 inch |
200 V |
NO |
GLASS FILLED POLYAMIDE |
1 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
25 A |
UL |
2 |
CABLE |
6.71 |
25A |
RECEPTACLE |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
FEMALE |
ONE |
NO |
1.701 inch |
NO |
NO |
NO |
.82 inch |
NOT APPLICABLE |
1.597 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
13 A |
UL |
12 |
0.175 |
CABLE |
9.12 |
13A |
CRIMP |
PLUG |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.931 inch |
NO |
NO |
NO |
1.06 inch |
NOT APPLICABLE |
1.048 inch |
200 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
25 A |
UL |
4 |
0.4 |
CABLE |
6.71 |
25A |
RECEPTACLE |
RND PIN-SKT |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
FEMALE |
ONE |
NO |
1.228 inch |
NO |
NO |
NO |
.591 inch |
NOT APPLICABLE |
.621 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
1 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
2 |
CABLE |
5.46 |
13A |
CRIMP |
PLUG |
RND PIN-SKT |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.44 inch |
NO |
NO |
NO |
1 inch |
1.489 inch |
250 V |
NO |
1 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
94V-0 |
POLARIZED HOUSING |
7.5 A |
UL |
3 |
PANEL |
4.19 |
7.5A |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||||||||||||
Aptiv |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
ONE |
.469 inch |
NO |
NO |
.404 inch |
1.299 inch |
NO |
NYLON |
125 |
NO |
NO |
-40 Cel |
YES |
COMPATIBLE CONTACTS: 12047581; 12059894 |
BLACK |
2 |
S0P2 |
CABLE |
Headers and Edge Type Connectors |
POLYAMIDE66 |
CRIMP |
10 mohm |
RECEPTACLE |
STRAIGHT |
SQ PIN-SKT |
LOCKING |
DETENT |
|||||||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.68 inch |
NO |
NO |
NO |
.816 inch |
NOT APPLICABLE |
.638 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
1 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
7.5 A |
UL |
3 |
CABLE |
4.19 |
7.5A |
RECEPTACLE |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.808 inch |
NO |
NO |
NO |
1.597 inch |
NOT APPLICABLE |
.876 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
12 |
0.175 |
CABLE |
9.12 |
13A |
CRIMP |
RECEPTACLE |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
ONE |
NO |
NO |
NO |
NO |
NOT APPLICABLE |
NO |
125 |
NO |
NO |
-40 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
30 A |
UL |
8 |
8.1 |
30A |
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.861 inch |
NO |
NO |
NO |
1.06 inch |
NOT APPLICABLE |
1.048 inch |
200 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
25 A |
UL |
4 |
0.4 |
CABLE |
6.71 |
25A |
RECEPTACLE |
RND PIN-SKT |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.808 inch |
NO |
NO |
NO |
2.17 inch |
NOT APPLICABLE |
1.4 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
12 |
0.175 |
PANEL |
9.12 |
MULTIPLE MATING PARTS AVAILABLE |
13A |
RECEPTACLE |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
ONE |
NO |
1.051 inch |
100000000 ohm |
NO |
NO |
NO |
.58 inch |
1.079 inch |
NO |
NYLON |
1 |
105 |
NO |
NO |
-55 Cel |
NO |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
COMPATIBLE CONTACTS: 350924-1; 770672-1 |
CSA, UL, V |
NATURAL |
4 |
S0P4 |
50 Cycles |
CABLE |
Headers and Edge Type Connectors |
POLYAMIDE |
6.35 |
MULTIPLE MATING PARTS AVAILABLE |
CRIMP |
PLUG |
STRAIGHT |
RND PIN-SKT |
22.24 |
LOCKING |
LATCH |
RECTANGULAR |
||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
FEMALE |
ONE |
NO |
1.611 inch |
NO |
NO |
NO |
.591 inch |
NOT APPLICABLE |
.621 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
1 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
2 |
CABLE |
5.46 |
13A |
CRIMP |
PLUG |
RND PIN-SKT |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
FEMALE |
ONE |
NO |
1.268 inch |
NO |
NO |
NO |
.82 inch |
NOT APPLICABLE |
.946 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
6 |
0.175 |
CABLE |
9.12 |
13A |
CRIMP |
PLUG |
RND PIN-SKT |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.861 inch |
NO |
NO |
NO |
.872 inch |
NOT APPLICABLE |
.848 inch |
200 V |
NO |
GLASS FILLED POLYAMIDE |
1 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
25 A |
UL |
2 |
CABLE |
6.71 |
25A |
RECEPTACLE |
RND PIN-SKT |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.083 inch |
NO |
NO |
NO |
.907 inch |
NOT APPLICABLE |
.907 inch |
600 V |
NO |
GLASS FILLED POLYBUTYLENE TEREPHTHALATE |
2 |
105 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
UL |
PURPLE |
B |
6 |
0.319 |
PANEL |
6 |
115/230VAC |
CRIMP |
PLUG |
SQ PIN-SKT |
RECTANGULAR |
||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.519 inch |
NO |
NO |
NO |
1.614 inch |
NOT APPLICABLE |
1.122 inch |
200 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
25 A |
UL |
4 |
0.4 |
PANEL |
6.71 |
25A |
RECEPTACLE |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.993 inch |
NO |
NO |
NO |
2.17 inch |
NOT APPLICABLE |
1.4 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
12 |
0.175 |
PANEL |
9.12 |
13A |
CRIMP |
RECEPTACLE |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||
|
Molex |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
ONE |
.935 inch |
20000000 ohm |
NO |
NO |
.865 inch |
NOT APPLICABLE |
NO |
120 |
NO |
NO |
-40 Cel |
NO |
NOT SPECIFIED |
NOT SPECIFIED |
UL |
4 |
S0P4 |
CABLE |
Headers and Edge Type Connectors |
CRIMP |
30 mohm |
PLUG |
STRAIGHT |
RND PIN-SKT |
62.272 |
LOCKING |
||||||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
ONE |
NO |
0.157 |
1.921 inch |
NO |
NO |
NO |
1.264 inch |
NOT APPLICABLE |
1.35 inch |
NO |
GLASS FILLED POLYBUTYLENE TEREPHTHALATE |
3 |
125 |
NO |
HOLE .078-.082 |
3.9878 |
NO |
-40 Cel |
YES |
1 |
3 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
17 A |
UL |
BLACK |
14 |
0.157 |
BOARD |
Headers and Edge Type Connectors |
4 |
STAGGERED |
17A |
SOLDER |
STRAIGHT |
RND PIN-SKT |
LOCKING |
STAGGERED |
||||||||||||||||||||||||||||||
|
TE Connectivity |
BOARD CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.72 inch |
NO |
NO |
NO |
.796 inch |
NOT APPLICABLE |
1.245 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
7.5 A |
UL |
8 |
0.28 |
CABLE |
4.19 |
7.5A |
RECEPTACLE |
RND PIN-SKT |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
FEMALE |
ONE |
NO |
1.218 inch |
NO |
NO |
NO |
.716 inch |
NOT APPLICABLE |
1.597 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
13 A |
UL |
12 |
0.175 |
CABLE |
9.12 |
13A |
CRIMP |
PLUG |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.868 inch |
NO |
NO |
NO |
.82 inch |
NOT APPLICABLE |
.776 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
4 |
0.359 |
CABLE |
4.45 |
13A |
CRIMP |
RECEPTACLE |
RND PIN-SKT |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||
Aptiv |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
FEMALE |
ONE |
.325 inch |
NO |
NO |
.343 inch |
.669 inch |
NO |
NYLON |
1 |
125 |
NO |
NO |
-40 Cel |
NO |
COMPITABLE CONTACT: 12047883 |
BLACK |
2 |
S0P2 |
CABLE |
Headers and Edge Type Connectors |
POLYAMIDE66 |
12047663 |
CRIMP |
10 mohm |
PLUG |
STRAIGHT |
SQ PIN-SKT |
LOCKING |
DETENT |
|||||||||||||||||||||||||||||||||||||||||||
|
Aptiv |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
FEMALE |
ONE |
0.236 |
NO |
NO |
.453 inch |
1.024 inch |
1 |
125 |
-40 Cel |
NO |
197u |
POLARIZED HOUSING |
14 A |
4 |
CABLE |
12162102 |
CRIMP |
BLADE PIN-SKT |
RECTANGULAR |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
FEMALE |
ONE |
NO |
1.08 inch |
1000000000 ohm |
NO |
NO |
NO |
.55 inch |
NOT APPLICABLE |
1.075 inch |
600 V |
NO |
POLYAMIDE |
2 |
105 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
COMPATIBLE CONTACTS: 350924-1; 770672-1 |
CSA, UL, V |
NATURAL |
6 |
S0P6 |
50 Cycles |
0.25 |
CABLE |
Headers and Edge Type Connectors |
POLYAMIDE |
6.35 |
MULTIPLE MATING PARTS AVAILABLE |
115/230VAC |
CRIMP |
PLUG |
STRAIGHT |
RND PIN-SKT |
22.24 |
LATCH |
.46 inch |
LOCKING |
RECTANGULAR |
||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.78 inch |
NO |
NO |
NO |
.796 inch |
NOT APPLICABLE |
1.245 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
7.5 A |
UL |
8 |
0.28 |
CABLE |
4.19 |
7.5A |
RECEPTACLE |
RND PIN-SKT |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
2.043 inch |
NO |
NO |
NO |
1.597 inch |
NOT APPLICABLE |
.876 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
12 |
0.175 |
CABLE |
9.12 |
13A |
CRIMP |
RECEPTACLE |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
FEMALE |
ONE |
NO |
1.601 inch |
NO |
NO |
NO |
.796 inch |
NOT APPLICABLE |
.968 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
3 |
CABLE |
10.01 |
MULTIPLE MATING PARTS AVAILABLE |
13A |
CRIMP |
PLUG |
RND PIN-SKT |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
FEMALE |
ONE |
NO |
.854 inch |
NO |
NO |
NO |
.988 inch |
NOT APPLICABLE |
.902 inch |
600 V |
NO |
GLASS FILLED POLYBUTYLENE TEREPHTHALATE |
2 |
105 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
UL |
BLUE |
C |
6 |
0.319 |
CABLE |
6 |
115/230VAC |
CRIMP |
PLUG |
SQ PIN-SKT |
RECTANGULAR |
||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
2.181 inch |
NO |
NO |
NO |
.832 inch |
NOT APPLICABLE |
.973 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARISED |
13 A |
UL |
3 |
CABLE |
10.01 |
13A |
CRIMP |
RECEPTACLE |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
2.353 inch |
NO |
NO |
NO |
1.663 inch |
NOT APPLICABLE |
1.857 inch |
200 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
25 A |
UL |
4 |
0.4 |
PANEL |
6.71 |
25A |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
FEMALE |
ONE |
NO |
1.118 inch |
NO |
NO |
NO |
.591 inch |
NOT APPLICABLE |
.621 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
1 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
2 |
CABLE |
5.46 |
13A |
CRIMP |
PLUG |
RND PIN-SKT |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
2.043 inch |
NO |
NO |
NO |
1.597 inch |
NOT APPLICABLE |
.876 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
12 |
0.175 |
CABLE |
9.12 |
13A |
CRIMP |
RECEPTACLE |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
FEMALE |
ONE |
NO |
1.185 inch |
NO |
NO |
NO |
.6 inch |
NOT APPLICABLE |
1.245 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
150 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
7.5 A |
UL |
8 |
0.28 |
CABLE |
4.19 |
7.5A |
CRIMP |
PLUG |
RND PIN-SKT |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
.846 inch |
NO |
NO |
NO |
.632 inch |
NOT APPLICABLE |
.589 inch |
600 V |
NO |
GLASS FILLED POLYAMIDE |
1 |
140 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
UL, VDE |
GRAY |
A |
2 |
PANEL |
6 |
115/230VAC |
CRIMP |
RECTANGULAR |
|||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
FEMALE |
ONE |
NO |
0.098 |
.35 inch |
100000000 ohm |
NO |
NO |
NO |
.474 inch |
NOT APPLICABLE |
.787 inch |
NO |
GLASS FILLED THERMOPLASTIC |
1 |
105 |
NO |
PREASSEM CONN |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED HOUSING |
5 A |
CSA, UL |
BLACK |
3 |
CABLE |
Headers and Edge Type Connectors |
GLASS FILLED POLYESTER |
2.5 |
115/230VAC |
CRIMP |
.278 |
10 mohm |
RECEPTACLE |
SQ PIN-SKT |
LOCKING |
RECTANGULAR |
||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.24 inch |
NO |
NO |
NO |
NO |
POLYAMIDE |
105 |
NO |
NO |
-40 Cel |
YES |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
2 |
CABLE |
POLYAMIDE66 |
7.4 |
115/230VAC |
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
2.296 inch |
NO |
NO |
NO |
.82 inch |
NOT APPLICABLE |
.776 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
4 |
0.359 |
CABLE |
4.45 |
13A |
CRIMP |
RECEPTACLE |
RND PIN-SKT |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.78 inch |
NO |
NO |
NO |
.796 inch |
1.245 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
150 |
NO |
NO |
-55 Cel |
YES |
1 |
94V-0 |
POLARIZED |
7.5 A |
UL |
8 |
0.28 |
CABLE |
4.19 |
7.5A |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
FEMALE |
ONE |
NO |
0.165 |
.84 inch |
100000000 ohm |
NO |
NO |
NO |
1.17 inch |
NOT APPLICABLE |
.51 inch |
250 V |
NO |
POLYAMIDE66 |
5 |
85 |
NO |
LOOSE |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED HOUSING |
COMPATIBLE CONTACTS: 794000-1; 794000-2; 641294-1; 794001-1; 794001-2, PLUG |
9 A |
CSA, UL |
BLACK |
20 |
26 AWG |
25 Cycles |
0.165 |
PANEL |
18 AWG |
Headers and Edge Type Connectors |
4.2 |
MULTIPLE MATING PARTS AVAILABLE |
9A |
CRIMP |
.2502 |
PLUG |
.115 inch |
RND PIN-SKT |
LOCKING |
LOCKING |
RECTANGULAR |
|||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.335 inch |
NO |
NO |
NO |
1.08 inch |
NOT APPLICABLE |
1.073 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
POLARIZED |
13 A |
UL |
4 |
0.359 |
CABLE |
4.45 |
13A |
CRIMP |
RECEPTACLE |
RND PIN-SKT |
W/STRAIN RELIEF |
|||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
FEMALE |
ONE |
NO |
1.079 inch |
NO |
NO |
NO |
.679 inch |
NOT APPLICABLE |
.675 inch |
NO |
PBT-POLYESTER |
125 |
NO |
NO |
-40 Cel |
YES |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
POLARIZED |
CURRY |
2 |
CABLE |
8 |
115/230VAC |
CRIMP |
||||||||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
1.24 inch |
NO |
NO |
NO |
.5 inch |
1.24 inch |
NO |
POLYAMIDE |
1 |
105 |
NO |
NO |
-40 Cel |
YES |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
FASTIN-FASTON, COMPATIBLE CONTACTS: 63553-2; 62553-3; 60701-1; 962825-1; 962825-8 |
2 |
CABLE |
7.4 |
MULTIPLE MATING PARTS AVAILABLE |
115/230VAC |
|||||||||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
FEMALE |
ONE |
NO |
0.118 |
1.339 inch |
100000000 ohm |
NO |
NO |
NO |
.461 inch |
NOT APPLICABLE |
.553 inch |
250 V |
NO |
POLYAMIDE66 |
2 |
105 |
NO |
PREASSEM CONN |
NO |
-40 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED HOUSING |
5 A |
UL |
BLACK |
22 |
30 AWG |
0.118 |
CABLE |
20 AWG |
Headers and Edge Type Connectors |
3 |
MULTIPLE MATING PARTS AVAILABLE |
115/230VAC |
CRIMP |
.6672 |
RECEPTACLE |
SQ PIN-SKT |
6.672 |
LOCKING |
LATCH |
RECTANGULAR |
|||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
FEMALE |
ONE |
NO |
.421 inch |
NO |
NO |
NO |
.187 inch |
.845 inch |
500 V |
NO |
1 |
175 |
NO |
PREASSEM CONN |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
POLARIZED |
5 A |
BLACK |
N |
3 |
0.1 |
CABLE |
COMPOSITE |
2.54 |
5A |
22 |
CRIMP |
RECEPTACLE |
STRAIGHT |
RND PIN-SKT |
LATCHING |
3 |
|||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
5.35 inch |
NO |
NO |
NO |
2.54 inch |
NOT APPLICABLE |
1.993 inch |
250 V |
NO |
GLASS FILLED POLYAMIDE |
2 |
125 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-0 |
NOT SPECIFIED |
POLARIZED |
13 A |
UL |
48 |
0.175 |
PANEL |
9.12 |
13A |
RECEPTACLE |
W/STRAIN RELIEF |
||||||||||||||||||||||||||||||||||||||||
|
TE Connectivity |
COMBINATION LINE CONNECTOR |
GENERAL PURPOSE |
MALE |
ONE |
NO |
NO |
NO |
NO |
NOT APPLICABLE |
1.08 inch |
NO |
POLYAMIDE |
3 |
105 |
NO |
NO |
-55 Cel |
YES |
1 |
NOT SPECIFIED |
94V-2 |
NOT SPECIFIED |
MATE-N-LOK |
CSA, UL, V |
BLACK |
9 |
0.25 |
PANEL |
6.35 |
115/230VAC |
CRIMP |
RECEPTACLE |
RECTANGULAR |
Combination line connectors are a type of electrical connector that are designed to allow for the connection of multiple electrical lines or conductors using a single connector. They are commonly used in industrial applications, such as power distribution and motor control, where there is a need to connect multiple lines in a compact and efficient manner.
Combination line connectors are typically made from durable materials such as copper or aluminum, and feature a housing or enclosure that holds multiple connector blocks or terminals. The connectors are designed to accept a range of wire sizes and types, and may include features such as locking mechanisms or sealing to prevent moisture and dust from entering the connector.
One advantage of combination line connectors is their ability to simplify wiring and reduce the amount of space required for connections. By allowing multiple lines to be connected using a single connector, combination line connectors can reduce the overall size and complexity of electrical systems, and may also reduce the number of connectors and wiring points that need to be installed.
Combination line connectors are available in a variety of configurations, including screw terminals, crimp terminals, and insulation displacement connectors (IDCs). They may also include features such as fuse holders or circuit breakers for added safety and protection.