3 ohm Data Line Filters 17

Reset All
Part RoHS Manufacturer Filter Type Construction Maximum DC Resistance Maximum Frequency Material Rated Current Minimum Insulation Resistance Approvals (V) Power Supply (V) No. of Functions Technology Screening Level Output Impedance (ohm) High Pot Packing Method Mounting Type Rated Voltage No. of Terminals Sub-Category Dimensions Case Code Maximum Operating Temperature Attenuation At Maximum Frequency Minimum Attenuation Frequency Package Material Minimum Operating Temperature Attenuation At Minimum Frequency Terminal Finish Inductance Maximum Attenuation Frequency Manufacturer Series Height Width (mm) Diameter (mm) Maximum Insertion Loss Additional Features JESD-609 Code Minimum Frequency Operating Frequency (Hz) Series Length Capacitance

DLW5AHN402SQ2L

Murata Manufacturing

DATA LINE FILTER

3 ohm

.2 A

10 Mohm

2

4000 OHM

TAPE AND REEL

SURFACE MOUNT

50 V

4

L5.0XB3.6XH4.3 (mm)/L0.197XB0.142XH0.169 (inch)

85 Cel

-25 Cel

TIN

4.3 mm

3.6

OPEN MAGNETIC ONE CIRCUIT TYPE

e3

5 mm

DLP0NSN900HL2L

Murata Manufacturing

DATA LINE FILTER

3 ohm

.1 A

100 Mohm

2

90 OHM

TAPE

SURFACE MOUNT

5 V

4

L0.85XB0.65XH0.45 (mm)/L0.033XB0.026XH0.018 (inch)

85 Cel

-40 Cel

Tin (Sn)

.45 mm

0.65

e3

.85 mm

MCZ1210CH900L2TA0G

TDK

DATA LINE FILTER

3 ohm

.1 A

10 Mohm

2

90 OHM

TR, 7 INCH

SURFACE MOUNT

5 V

4

L1.25XB1.0XH0.5 (mm)/L0.049XB0.039XH0.02 (inch)

85 Cel

-40 Cel

Tin (Sn) - with Nickel (Ni) barrier

.5 mm

1.0

e3

1.25 mm

ACT1210D-101-2P-TL00

TDK

DATA LINE FILTER

3 ohm

.115 A

10 Mohm

2

AEC-Q200

TR, 13 INCH

SURFACE MOUNT

80 V

4

150 Cel

-40 Cel

100 uH

2.5 mm

2.5

3.9 mm

EXC24CG900U

Panasonic

DATA LINE FILTER

3 ohm

.1 A

2

90 OHM

TAPE AND REEL

SURFACE MOUNT

5 V

4

L1.25XB1.0XH0.5 (mm)/L0.049XB0.039XH0.02 (inch)

85 Cel

-40 Cel

Tin (Sn) - with Nickel (Ni) barrier

.5 mm

1.0

e3

1.25 mm

DLP0NSN900HL2

Murata Manufacturing

DATA LINE FILTER

3 ohm

.1 A

100 Mohm

2

90 OHM

SURFACE MOUNT

5 V

L0.85XB0.65XH0.45 (mm)/L0.033XB0.026XH0.018 (inch)

85 Cel

-40 Cel

.45 mm

0.65

COMMON MODE CHOKE

.85 mm

DLP0NSN900HL2B

Murata Manufacturing

DATA LINE FILTER

3 ohm

.1 A

100 Mohm

2

90 OHM

BULK

SURFACE MOUNT

5 V

4

L0.85XB0.65XH0.45 (mm)/L0.033XB0.026XH0.018 (inch)

85 Cel

-40 Cel

Tin (Sn)

.45 mm

0.65

BAG

e3

.85 mm

DLW5AHN402SQ2

Murata Manufacturing

DATA LINE FILTER

3 ohm

.2 A

10 Mohm

2

4000 OHM

SURFACE MOUNT

50 V

L5.0XB3.6XH4.3 (mm)/L0.197XB0.142XH0.169 (inch)

85 Cel

-25 Cel

TIN COPPER

4.3 mm

3.6

COMMON MODE CHOKE

e2

5 mm

DLW5AHN402SQ2B

Murata Manufacturing

DATA LINE FILTER

3 ohm

.2 A

10 Mohm

2

4000 OHM

BULK

SURFACE MOUNT

50 V

4

L5.0XB3.6XH4.3 (mm)/L0.197XB0.142XH0.169 (inch)

85 Cel

-25 Cel

TIN

4.3 mm

3.6

BAG

e3

5 mm

DLW5AHN402SQ2K

Murata Manufacturing

DATA LINE FILTER

3 ohm

.2 A

10 Mohm

2

4000 OHM

TAPE AND REEL

SURFACE MOUNT

50 V

4

L5.0XB3.6XH4.3 (mm)/L0.197XB0.142XH0.169 (inch)

85 Cel

-25 Cel

TIN

4.3 mm

3.6

OPEN MAGNETIC ONE CIRCUIT TYPE

e3

5 mm

EXC34CG900U

Panasonic

DATA LINE FILTER

3 ohm

.1 A

10 Mohm

2

90 OHM

TAPE AND REEL

SURFACE MOUNT

5 V

4

L2.0XB1.25XH0.5 (mm)/L0.079XB0.049XH0.02 (inch)

85 Cel

-40 Cel

.5 mm

1.25

2 mm

MCZ1210DH900L2TA0G

TDK

DATA LINE FILTER

3 ohm

.1 A

10 Mohm

2

90 OHM

TR, 7 INCH

SURFACE MOUNT

5 V

4

L1.25XB1.0XH0.5 (mm)/L0.049XB0.039XH0.02 (inch)

85 Cel

-40 Cel

.5 mm

1.0

1.25 mm

ACT45B-101-2P-TL

TDK

DATA LINE FILTER

3 ohm

.15 A

10 Mohm

2

AEC-Q200

5000 OHM

TAPE AND REEL

SURFACE MOUNT

50 V

4

L4.5XB3.2XH2.8 (mm)/L0.177XB0.126XH0.11 (inch)

150 Cel

-40 Cel

100 uH

2.8 mm

3.2

IMPEDANCE AT 10 MHZ

4.5 mm

LCFE060502A120TG

Littelfuse

DATA LINE FILTER

3 ohm

.1 A

10 Mohm

2

12 OHM

TR, 7 INCH

SURFACE MOUNT

5 V

6

85 Cel

CERAMIC

-40 Cel

.35 mm

0.55

.68 mm

1.2 uF

MCZ1210CH900L2T

TDK

DATA LINE FILTER

3 ohm

.1 A

10 Mohm

2

90 OHM

TAPE AND REEL

SURFACE MOUNT

5 V

4

L1.25XB1.0XH0.5 (mm)/L0.049XB0.039XH0.02 (inch)

85 Cel

-40 Cel

.5 mm

1.0

1.25 mm

TCM0605G-900-2P-T201

TDK

DATA LINE FILTER

3 ohm

.1 A

10 Mohm

2

90 OHM

TR, 7 INCH

SURFACE MOUNT

10 V

L0.65XB0.5XH0.3 (mm)/L0.026XB0.02XH0.012 (inch)

85 Cel

-25 Cel

.3 mm

0.5

.65 mm

BU15-4530R4BL

Coilcraft

DATA LINE FILTER

3 ohm

.4 A

2

398700 OHM

TRAY

THROUGH HOLE MOUNT

4

L23.0XB19.0XH27.5 (mm)/L0.906XB0.748XH1.083 (inch)

125 Cel

-40 Cel

Tin/Silver (Sn/Ag)

45000 uH

27.5 mm

19

e2

23 mm

Data Line Filters

Data line filters are electronic filters that are used to filter out noise and interference from data communication lines. They are designed to provide a high level of attenuation of unwanted frequencies while allowing the desired data signal to pass through with minimal distortion.

Data line filters use a combination of passive and active components, including resistors, capacitors, inductors, and op-amps, to filter out noise and interference from data communication lines. They can be designed for a wide range of communication standards, including Ethernet, USB, HDMI, and other data communication protocols.

Data line filters can be designed as low-pass filters, which allow low-frequency signals to pass through while attenuating high-frequency signals, or as band-stop filters, which block a specific range of frequencies while allowing other frequencies to pass through. They can also be designed with multiple stages of filtering to provide increased attenuation of unwanted frequencies.

Data line filters are commonly used in a variety of electronic systems, including computers, telecommunication equipment, medical equipment, and industrial control systems. They are also used in data centers and other applications where high-speed data communication is critical.