16 A Data Line Filters 6

Reset All
Part RoHS Manufacturer Filter Type Construction Maximum DC Resistance Maximum Frequency Material Rated Current Minimum Insulation Resistance Approvals (V) Power Supply (V) No. of Functions Technology Screening Level Output Impedance (ohm) High Pot Packing Method Mounting Type Rated Voltage No. of Terminals Sub-Category Dimensions Case Code Maximum Operating Temperature Attenuation At Maximum Frequency Minimum Attenuation Frequency Package Material Minimum Operating Temperature Attenuation At Minimum Frequency Terminal Finish Inductance Maximum Attenuation Frequency Manufacturer Series Height Width (mm) Diameter (mm) Maximum Insertion Loss Additional Features JESD-609 Code Minimum Frequency Operating Frequency (Hz) Series Length Capacitance

RB6122-16-1M0

Schaffner Holding Ag

DATA LINE FILTER

.0048 ohm

16 A

UL

1

THROUGH HOLE MOUNT

1000 V

L53.3XB51.34XH41.5 (mm)/L2.098XB2.021XH1.634 (inch)

125 Cel

-40 Cel

1000 uH

41.5 mm

51.34

53.3 mm

RB8532-16-1M3

Schaffner Holding Ag

DATA LINE FILTER

.0057 ohm

16 A

IEC; UL

3

PANEL MOUNT

1000 V

6

125 Cel

-40 Cel

1300 uH

58 mm

55

58 mm

8115-RC

Bourns

DATA LINE FILTER

.006 ohm

16 A

UL

2

THROUGH HOLE MOUNT

4

L38.1XB20.701XH38.86 (mm)/L1.50XB0.815XH1.53 (inch)

105 Cel

-55 Cel

1200 uH

38.86 mm

20.32

38.1 mm

FN7562-16-M4

Schaffner Holding Ag

FEED THROUGH CAPACITOR

.0006 ohm

16 A

1500 Mohm

UL; ENEC-14

1

PANEL MOUNT

130 V

D17.0XH30.0 (mm)/D0.669XH1.181 (inch)

100 Cel

-40 Cel

30 mm

17

100000 uF

RT8132-16-3M0

Schaffner Holding Ag

DATA LINE FILTER

.01 ohm

16 A

UL

2

THROUGH HOLE MOUNT

600 V

4

100 Cel

-40 Cel

3000 uH

37 mm

57

TCK-103

Traco Electronic Ag

DATA LINE FILTER

.006 ohm

16 A

2

THROUGH HOLE MOUNT

500 V

4

105 Cel

-40 Cel

285 uH

15 mm

16

16 mm

Data Line Filters

Data line filters are electronic filters that are used to filter out noise and interference from data communication lines. They are designed to provide a high level of attenuation of unwanted frequencies while allowing the desired data signal to pass through with minimal distortion.

Data line filters use a combination of passive and active components, including resistors, capacitors, inductors, and op-amps, to filter out noise and interference from data communication lines. They can be designed for a wide range of communication standards, including Ethernet, USB, HDMI, and other data communication protocols.

Data line filters can be designed as low-pass filters, which allow low-frequency signals to pass through while attenuating high-frequency signals, or as band-stop filters, which block a specific range of frequencies while allowing other frequencies to pass through. They can also be designed with multiple stages of filtering to provide increased attenuation of unwanted frequencies.

Data line filters are commonly used in a variety of electronic systems, including computers, telecommunication equipment, medical equipment, and industrial control systems. They are also used in data centers and other applications where high-speed data communication is critical.