18 A Data Line Filters 11

Reset All
Part RoHS Manufacturer Filter Type Construction Maximum DC Resistance Maximum Frequency Material Rated Current Minimum Insulation Resistance Approvals (V) Power Supply (V) No. of Functions Technology Screening Level Output Impedance (ohm) High Pot Packing Method Mounting Type Rated Voltage No. of Terminals Sub-Category Dimensions Case Code Maximum Operating Temperature Attenuation At Maximum Frequency Minimum Attenuation Frequency Package Material Minimum Operating Temperature Attenuation At Minimum Frequency Terminal Finish Inductance Maximum Attenuation Frequency Manufacturer Series Height Width (mm) Diameter (mm) Maximum Insertion Loss Additional Features JESD-609 Code Minimum Frequency Operating Frequency (Hz) Series Length Capacitance

M-FIAM9H21

Vicor

DATA LINE FILTER MODULE

18 A

1

PANEL MOUNT

36 V

9

100 Cel

-40 Cel

TIN LEAD

13.5 mm

55.88

57.91 mm

M-FIAM9HN1

Vicor

DATA LINE FILTER MODULE

18 A

1

PANEL MOUNT

36 V

9

100 Cel

-40 Cel

TIN LEAD

13.5 mm

55.88

57.91 mm

M-FIAM9HG1

Vicor

DATA LINE FILTER MODULE

18 A

1

PANEL MOUNT

36 V

9

100 Cel

-40 Cel

GOLD

13.5 mm

55.88

57.91 mm

M-FIAM9H22

Vicor

DATA LINE FILTER MODULE

18 A

1

PANEL MOUNT

36 V

9

100 Cel

-40 Cel

TIN LEAD

13.5 mm

55.88

57.91 mm

M-FIAM9HS1

Vicor

DATA LINE FILTER MODULE

18 A

1

PANEL MOUNT

36 V

9

100 Cel

-40 Cel

TIN LEAD

13.5 mm

55.88

57.91 mm

M-FIAM9M21

Vicor

DATA LINE FILTER MODULE

18 A

1

PANEL MOUNT

36 V

9

100 Cel

-55 Cel

TIN LEAD

13.5 mm

55.88

57.91 mm

M-FIAM9M22

Vicor

DATA LINE FILTER MODULE

18 A

1

PANEL MOUNT

36 V

9

100 Cel

-55 Cel

TIN LEAD

13.5 mm

55.88

57.91 mm

PLT10HH450180PNL

Murata Manufacturing

DATA LINE FILTER

.0013 ohm

18 A

10 Mohm

2

AEC-Q200

450 OHM

TR, EMBOSSED, 7 INCH

SURFACE MOUNT

300 V

L12.9XB6.6XH9.4 (mm)/L0.508XB0.26XH0.37 (inch)

125 Cel

-55 Cel

.8 uH

9.4 mm

6.6

IMPEDANCE AT 10 MHZ

12.9 mm

M-FIAM9HG2

Vicor

DATA LINE FILTER MODULE

18 A

1

PANEL MOUNT

36 V

9

100 Cel

-40 Cel

GOLD

13.5 mm

55.88

57.91 mm

T60405-R6166-X033

Vacuumschmelze & Kg

DATA LINE FILTER

18 A

UL; EN

2

THROUGH HOLE MOUNT

L38.0XB21.0XH38.0 (mm)/L1.496XB0.827XH1.496 (inch)

70 Cel

-40 Cel

6000 uH

38 mm

21.0

38 mm

SC-18-100

KEMET Corporation

MAINS FILTER

.02 ohm

18 A

2

BOX; TRAY

THROUGH HOLE MOUNT

250 V

4

120 Cel

-25 Cel

700 uH

23 mm

34

COMMON MODE CHOKE

Data Line Filters

Data line filters are electronic filters that are used to filter out noise and interference from data communication lines. They are designed to provide a high level of attenuation of unwanted frequencies while allowing the desired data signal to pass through with minimal distortion.

Data line filters use a combination of passive and active components, including resistors, capacitors, inductors, and op-amps, to filter out noise and interference from data communication lines. They can be designed for a wide range of communication standards, including Ethernet, USB, HDMI, and other data communication protocols.

Data line filters can be designed as low-pass filters, which allow low-frequency signals to pass through while attenuating high-frequency signals, or as band-stop filters, which block a specific range of frequencies while allowing other frequencies to pass through. They can also be designed with multiple stages of filtering to provide increased attenuation of unwanted frequencies.

Data line filters are commonly used in a variety of electronic systems, including computers, telecommunication equipment, medical equipment, and industrial control systems. They are also used in data centers and other applications where high-speed data communication is critical.