4 A EMI Mains Filters 16

Reset All
Part RoHS Manufacturer Filter Type Maximum DC Resistance Maximum Frequency Rated Current Minimum Insulation Resistance Approvals (V) Insertion Loss At Minimum Frequency No. of Functions Screening Level High Pot Maximum Leakage Current Packing Method Mounting Type Rated Voltage No. of Terminals Sub-Category Dimensions Maximum Operating Temperature Insertion Loss At Maximum Frequency Package Material Minimum Operating Temperature Terminal Finish Inductance Manufacturer Series Height Width (mm) Diameter (mm) Additional Features JESD-609 Code Minimum Frequency Operating Frequency (Hz) Length

RN112-4-02-0M7

Schaffner Holding Ag

SINGLE PHASE EMI FILTER

4 A

UL; IEC; VDE; ENEC-10

TUBE

THROUGH HOLE MOUNT

300 V

L17.7XB17.1XH12.6 (mm)/L0.697XB0.673XH0.496 (inch)

100 Cel

-40 Cel

12.6 mm

17.1

50/60Hz

17.7 mm

7448030417

Wurth Elektronik

SINGLE PHASE EMI FILTER

4 A

ENEC-10; VDE

TRAY

THROUGH HOLE MOUNT

250 V

125 Cel

-40 Cel

25 mm

13.5

50Hz

22 mm

RN212-4-02-0M7

Schaffner Holding Ag

SINGLE PHASE EMI FILTER

4 A

UL; IEC; VDE; ENEC-10

THROUGH HOLE MOUNT

300 V

L18.0XB12.5XH20.0 (mm)/L0.709XB0.492XH0.787 (inch)

100 Cel

-40 Cel

20 mm

12.5

50/60Hz

18 mm

RN114-4-02-1M5

Schaffner Holding Ag

SINGLE PHASE EMI FILTER

4 A

UL; IEC; VDE; ENEC-10

THROUGH HOLE MOUNT

300 V

L22.5XB21.5XH13.2 (mm)/L0.886XB0.846XH0.52 (inch)

100 Cel

-40 Cel

13.2 mm

21.5

50/60Hz

22.5 mm

NAC-04-472-D

Cosel

SINGLE PHASE EMI FILTER

4 A

UL; CSA; VDE; ENEC-10

2500 V

1 mA

DIN RAIL MOUNT

250 V

L92.0XB53.0XH41.0 (mm)/L3.622XB2.087XH1.614 (inch)

85 Cel

-40 Cel

41 mm

53.0

60Hz

92 mm

744841414

Wurth Elektronik

SINGLE PHASE EMI FILTER

4 A

ENEC-10; IEC; VDE

TRAY; PAPER

THROUGH HOLE MOUNT

250 V

L16.0XB7.5XH17.5 (mm)/L0.63XB0.295XH0.689 (inch)

125 Cel

-40 Cel

Tin/Silver/Copper (Sn/Ag/Cu)

17.5 mm

7.5

e1

50Hz

16 mm

RN122-4-02-1M8

Schaffner Holding Ag

SINGLE PHASE EMI FILTER

4 A

UL; IEC; VDE; ENEC-10

THROUGH HOLE MOUNT

300 V

L28.0XB27.0XH16.5 (mm)/L1.102XB1.063XH0.65 (inch)

100 Cel

-40 Cel

16.5 mm

27.0

50/60Hz

28 mm

RN122-4-02-3M3

Schaffner Holding Ag

SINGLE PHASE EMI FILTER

4 A

UL; IEC; VDE; ENEC-10

THROUGH HOLE MOUNT

300 V

L28.0XB27.0XH16.5 (mm)/L1.102XB1.063XH0.65 (inch)

100 Cel

-40 Cel

16.5 mm

27.0

50/60Hz

28 mm

RN122-4-02

Schaffner Holding Ag

SINGLE PHASE EMI FILTER

4 A

UL; VDE

THROUGH HOLE MOUNT

250 V

125 Cel

-40 Cel

16.5 mm

27

50/60Hz

28 mm

5500.2003

Schurter Ag

SINGLE PHASE EMI FILTER

4 A

UL; CUL; VDE; ENEC-10

2700 V

.25 mA

THROUGH HOLE MOUNT

250 V

5

L25.0XB25.0XH25.0 (mm)/L0.984XB0.984XH0.984 (inch)

85 Cel

-25 Cel

TIN

25 mm

25.0

INDUCTANCE 1.5 MILLIHENRY

e3

60Hz

25 mm

744834405

Wurth Elektronik

SINGLE PHASE EMI FILTER

4 A

THROUGH HOLE MOUNT

250 V

4

L32.5XB28.0XH22.0 (mm)/L1.28XB1.102XH0.866 (inch)

125 Cel

-40 Cel

Tin (Sn) over Copper (Cu)

22 mm

28.0

50Hz

32.5 mm

RN114-4-02

Schaffner Holding Ag

SINGLE PHASE EMI FILTER

4 A

UL; VDE

THROUGH HOLE MOUNT

250 V

125 Cel

-40 Cel

13.2 mm

21.5

50/60Hz

22.5 mm

RN222-4-02-3M3

Schaffner Holding Ag

SINGLE PHASE EMI FILTER

4 A

UL; IEC; VDE; ENEC-10

THROUGH HOLE MOUNT

300 V

L31.0XB18.0XH29.3 (mm)/L1.22XB0.709XH1.154 (inch)

100 Cel

-40 Cel

29.3 mm

18.0

50/60Hz

31 mm

SC-05-50J

KEMET Corporation

SINGLE PHASE EMI FILTER

4 A

100 Mohm

UL

TRAY

THROUGH HOLE MOUNT

250 V

L34.0XB23.0XH33.0 (mm)/L1.339XB0.906XH1.299 (inch)

105 Cel

-25 Cel

33 mm

23.0

34 mm

SS30V-400021

KEMET Corporation

SINGLE PHASE EMI FILTER

4 A

100 Mohm

UL

500 V

TRAY

THROUGH HOLE MOUNT

250 V

120 Cel

-25 Cel

33 mm

22.5

31 mm

SSRH24NVS-40059

KEMET Corporation

SINGLE PHASE EMI FILTER

4 A

100 Mohm

UL

TRAY

THROUGH HOLE MOUNT

250 V

120 Cel

-25 Cel

31 mm

20

25.5 mm

EMI Mains Filters

EMI mains filters are electronic filters that are used to suppress electromagnetic interference (EMI) from mains power lines. They are designed to provide a high level of attenuation of unwanted frequencies while allowing the desired power signal to pass through with minimal distortion.

EMI mains filters use a combination of passive and active components, including capacitors, inductors, resistors, and diodes, to filter out noise and interference from power lines. They can be designed for a wide range of power ratings and frequencies, depending on the application.

EMI mains filters can be designed as low-pass filters, which allow low-frequency power signals to pass through while attenuating high-frequency EMI signals, or as band-stop filters, which block a specific range of frequencies while allowing other frequencies to pass through. They can also be designed with multiple stages of filtering to provide increased attenuation of unwanted frequencies.

EMI mains filters are commonly used in a variety of electronic systems, including power supplies, motor drives, medical equipment, and industrial control systems. They are also used in residential and commercial buildings to suppress EMI noise from power lines and prevent interference with other electronic devices.