Part | RoHS | Manufacturer | Filter Type | Maximum DC Resistance | Maximum Frequency | Rated Current | Minimum Insulation Resistance | Approvals (V) | Insertion Loss At Minimum Frequency | No. of Functions | Screening Level | High Pot | Maximum Leakage Current | Packing Method | Mounting Type | Rated Voltage | No. of Terminals | Sub-Category | Dimensions | Maximum Operating Temperature | Insertion Loss At Maximum Frequency | Package Material | Minimum Operating Temperature | Terminal Finish | Inductance | Manufacturer Series | Height | Width (mm) | Diameter (mm) | Additional Features | JESD-609 Code | Minimum Frequency | Operating Frequency (Hz) | Length |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Triad Magnetics |
SINGLE PHASE EMI FILTER |
UL; CSA; IEC; VDE |
THROUGH HOLE MOUNT |
4 |
L36.83XB20.32XH38.1 (mm)/L1.45XB0.8XH1.5 (inch) |
38.1 mm |
20.32 |
INDUCTANCE 2 MILLI HENRY |
36.83 mm |
||||||||||||||||||||||||
|
Schurter Ag |
SINGLE PHASE EMI FILTER |
12 A |
CSA; ENEC-10; IEC; UL; VDE |
2500 V |
THROUGH HOLE MOUNT |
425 V |
100 Cel |
-40 Cel |
26 mm |
37 |
0-400 |
||||||||||||||||||||||
|
Schurter Ag |
THREE PHASE EMI FILTER |
50 A |
IEC; UL |
3740 V |
THROUGH HOLE MOUNT |
600 V |
100 Cel |
-40 Cel |
31 mm |
58 |
0-400Hz |
||||||||||||||||||||||
|
Cosel |
SINGLE PHASE EMI FILTER |
10 A |
UL; CSA; VDE; ENEC-10 |
2500 V |
1 mA |
CHASSIS MOUNT |
250 V |
L85.0XB39.0XH30.0 (mm)/L3.346XB1.535XH1.181 (inch) |
85 Cel |
-40 Cel |
30 mm |
39.0 |
60Hz |
85 mm |
|||||||||||||||||||
|
Schaffner Holding Ag |
SINGLE PHASE EMI FILTER |
13.8 A |
UL; CSA; ENEC-14 |
2000 V |
.74 mA |
PANEL MOUNT |
250 V |
L43.5XB32.5XH29.3 (mm)/L1.713XB1.28XH1.154 (inch) |
100 Cel |
-25 Cel |
29.3 mm |
32.5 |
INDUCTANCE 0.7 MILLIHENRY |
50/60Hz |
43.5 mm |
||||||||||||||||||
|
Schaffner Holding Ag |
SINGLE PHASE EMI FILTER |
23 A |
UL; CSA; ENEC-14 |
2000 V |
.74 mA |
CHASSIS MOUNT |
250 V |
L64.8XB49.8XH30.3 (mm)/L2.551XB1.961XH1.193 (inch) |
100 Cel |
-25 Cel |
30.3 mm |
49.8 |
INDUCTANCE 0.6 MILLIHENRY |
50/60Hz |
64.8 mm |
||||||||||||||||||
|
Schaffner Holding Ag |
SINGLE PHASE EMI FILTER |
23 A |
UL; CSA; ENEC-14 |
2000 V |
.074 mA |
CHASSIS MOUNT |
250 V |
L64.8XB49.8XH30.3 (mm)/L2.551XB1.961XH1.193 (inch) |
100 Cel |
-25 Cel |
30.3 mm |
49.8 |
INDUCTANCE 0.6 MILLIHENRY |
50/60Hz |
64.8 mm |
||||||||||||||||||
|
Schaffner Holding Ag |
SINGLE PHASE EMI FILTER |
11.5 A |
UL; CSA; ENEC-14 |
1100 V |
.734 mA |
CHASSIS MOUNT |
250 V |
L130.5XB56.0XH45.4 (mm)/L5.138XB2.205XH1.787 (inch) |
100 Cel |
-25 Cel |
45.4 mm |
56.0 |
INDUCTANCE 4.5 MILLIHENRY |
50/60Hz |
130.5 mm |
||||||||||||||||||
|
Schaffner Holding Ag |
SINGLE PHASE EMI FILTER |
11.5 A |
UL; CSA; ENEC-14 |
1100 V |
.734 mA |
CHASSIS MOUNT |
250 V |
L130.5XB56.0XH45.4 (mm)/L5.138XB2.205XH1.787 (inch) |
100 Cel |
-25 Cel |
45.4 mm |
56.0 |
INDUCTANCE 4.5 MILLIHENRY |
50/60Hz |
130.5 mm |
||||||||||||||||||
|
Schaffner Holding Ag |
SINGLE PHASE EMI FILTER |
100 A |
UL; CSA; ENEC-14 |
1100 V |
3.4 mA |
DIN RAIL MOUNT |
250 V |
L140.0XB115.0XH100.0 (mm)/L5.512XB4.528XH3.937 (inch) |
100 Cel |
-25 Cel |
100 mm |
115.0 |
400Hz |
140 mm |
|||||||||||||||||||
|
Schaffner Holding Ag |
SINGLE PHASE EMI FILTER |
16 A |
UL; CSA; ENEC-14 |
1100 V |
3.4 mA |
DIN RAIL MOUNT |
250 V |
L110.0XB93.0XH73.0 (mm)/L4.331XB3.661XH2.874 (inch) |
100 Cel |
-25 Cel |
73 mm |
93.0 |
400Hz |
110 mm |
|||||||||||||||||||
|
Schaffner Holding Ag |
THREE PHASE EMI FILTER |
11.5 A |
UL; CSA; SEMKO |
1900 V |
.07 mA |
PANEL MOUNT |
440 V |
L65.0XB50.0XH40.3 (mm)/L2.559XB1.969XH1.587 (inch) |
100 Cel |
-25 Cel |
40.3 mm |
50.0 |
AMP FAST-ON CONNECTIONS |
400Hz |
65 mm |
||||||||||||||||||
|
Schaffner Holding Ag |
THREE PHASE EMI FILTER |
25 A |
UL; CSA; ENEC-14 |
2000 V |
.43 mA |
PANEL MOUNT |
440 V |
L140.0XB105.0XH80.0 (mm)/L5.512XB4.134XH3.15 (inch) |
100 Cel |
-25 Cel |
80 mm |
105.0 |
60Hz |
140 mm |
|||||||||||||||||||
|
Schaffner Holding Ag |
THREE PHASE EMI FILTER |
6.9 A |
UL; CSA; EN |
590 V |
.44 mA |
PANEL MOUNT |
250 V |
L200.0XB80.0XH50.0 (mm)/L7.874XB3.15XH1.969 (inch) |
85 Cel |
-25 Cel |
50 mm |
80.0 |
50/60Hz |
200 mm |
|||||||||||||||||||
|
KEMET Corporation |
SINGLE PHASE EMI FILTER |
2 A |
300 Mohm |
CSA;UL |
.75 mA |
TRAY |
CHASSIS MOUNT |
250 V |
55 Cel |
-25 Cel |
27 mm |
40 |
49 mm |
||||||||||||||||||||
|
Cosel |
SINGLE PHASE EMI FILTER |
20 A |
UL; CSA; VDE; ENEC-10 |
2500 V |
1 mA |
CHASSIS MOUNT |
250 V |
L92.0XB53.0XH41.0 (mm)/L3.622XB2.087XH1.614 (inch) |
85 Cel |
-40 Cel |
41 mm |
53.0 |
60Hz |
92 mm |
|||||||||||||||||||
|
Cosel |
SINGLE PHASE EMI FILTER |
10 A |
UL; CSA; VDE; ENEC-10 |
2500 V |
1 mA |
DIN RAIL MOUNT |
250 V |
L92.0XB53.0XH41.0 (mm)/L3.622XB2.087XH1.614 (inch) |
85 Cel |
-40 Cel |
41 mm |
53.0 |
60Hz |
92 mm |
|||||||||||||||||||
|
Murata Manufacturing |
SINGLE PHASE EMI FILTER |
.3 A |
100 Mohm |
BOX |
THROUGH HOLE MOUNT |
300 V |
L18.0XB16.0XH17.5 (mm)/L0.709XB0.63XH0.689 (inch) |
120 Cel |
-25 Cel |
Tin/Copper (Sn/Cu) |
17.5 mm |
16.0 |
INDUCTANCE 43 MILLI HENRY; STANDARD WINDING TYPE |
e2 |
18 mm |
||||||||||||||||||
|
Schaffner Holding Ag |
DATA LINE FILTER |
||||||||||||||||||||||||||||||||
|
Schaffner Holding Ag |
SINGLE PHASE EMI FILTER |
Matte Tin (Sn) |
e3 |
||||||||||||||||||||||||||||||
|
Schaffner Holding Ag |
SINGLE PHASE EMI FILTER |
4 A |
UL; VDE |
THROUGH HOLE MOUNT |
250 V |
125 Cel |
-40 Cel |
13.2 mm |
21.5 |
50/60Hz |
22.5 mm |
||||||||||||||||||||||
|
Schaffner Holding Ag |
SINGLE PHASE EMI FILTER |
.5 A |
UL; IEC; VDE; ENEC-10 |
THROUGH HOLE MOUNT |
300 V |
L18.0XB12.5XH20.0 (mm)/L0.709XB0.492XH0.787 (inch) |
100 Cel |
-40 Cel |
20 mm |
12.5 |
50/60Hz |
18 mm |
|||||||||||||||||||||
|
Schaffner Holding Ag |
SINGLE PHASE EMI FILTER |
.6 A |
UL; IEC; VDE; ENEC-10 |
THROUGH HOLE MOUNT |
300 V |
L18.0XB12.5XH20.0 (mm)/L0.709XB0.492XH0.787 (inch) |
100 Cel |
-40 Cel |
20 mm |
12.5 |
50/60Hz |
18 mm |
|||||||||||||||||||||
|
Astrodyne Tdi |
SINGLE PHASE EMI FILTER |
10 A |
CSA; EN; UL |
2700 V |
1.8 mA |
CHASSIS MOUNT |
250 V |
100 Cel |
-25 Cel |
RP135 |
17 mm |
44 |
50-60Hz |
44 mm |
|||||||||||||||||||
Astrodyne Tdi |
THREE PHASE EMI FILTER |
300 A |
EN; UL |
3500 V |
1 mA |
PANEL MOUNT |
480 V |
100 Cel |
-25 Cel |
RP400 |
114 mm |
168 |
50-60Hz |
330 mm |
||||||||||||||||||||
|
TDK |
SINGLE PHASE EMI FILTER |
6 A |
UL; CSA; EN |
1 mA |
DIN RAIL MOUNT |
250 V |
L98.0XB52.0XH35.0 (mm)/L3.858XB2.047XH1.378 (inch) |
85 Cel |
-25 Cel |
35 mm |
52.0 |
60Hz |
98 mm |
||||||||||||||||||||
|
TDK |
THREE PHASE EMI FILTER |
10 A |
100 Mohm |
UL; EN |
2500 V |
5 mA |
PANEL MOUNT |
500 V |
L127.0XB63.0XH50.4 (mm)/L5.0XB2.48XH1.984 (inch) |
85 Cel |
-25 Cel |
50.4 mm |
63.0 |
60Hz |
127 mm |
||||||||||||||||||
|
KEMET Corporation |
SINGLE PHASE EMI FILTER |
||||||||||||||||||||||||||||||||
|
KEMET Corporation |
SINGLE PHASE EMI FILTER |
||||||||||||||||||||||||||||||||
|
KEMET Corporation |
SINGLE PHASE EMI FILTER |
||||||||||||||||||||||||||||||||
|
KEMET Corporation |
SINGLE PHASE EMI FILTER |
2.2 A |
100 Mohm |
THROUGH HOLE MOUNT |
250 V |
L22.0XB14.5XH19.5 (mm)/L0.866XB0.571XH0.768 (inch) |
75 Cel |
-25 Cel |
19.5 mm |
14.5 |
INDUCTANCE 2 MILLI HENRY |
22 mm |
|||||||||||||||||||||
|
KEMET Corporation |
SINGLE PHASE EMI FILTER |
.8 A |
100 Mohm |
UL |
500 V |
TRAY |
THROUGH HOLE MOUNT |
250 V |
L26.0XB20.5XH30.5 (mm)/L1.024XB0.807XH1.201 (inch) |
120 Cel |
-25 Cel |
30.5 mm |
20.5 |
26 mm |
|||||||||||||||||||
|
KEMET Corporation |
SINGLE PHASE EMI FILTER |
3 A |
100 Mohm |
UL |
500 V |
TRAY |
THROUGH HOLE MOUNT |
250 V |
130 Cel |
-25 Cel |
15.5 mm |
17 |
22 mm |
||||||||||||||||||||
|
KEMET Corporation |
SINGLE PHASE EMI FILTER |
1 A |
100 Mohm |
UL |
500 V |
TRAY |
THROUGH HOLE MOUNT |
250 V |
130 Cel |
-25 Cel |
15.5 mm |
23 |
26 mm |
||||||||||||||||||||
|
KEMET Corporation |
SINGLE PHASE EMI FILTER |
1.5 A |
100 Mohm |
UL |
500 V |
TRAY |
THROUGH HOLE MOUNT |
250 V |
130 Cel |
-25 Cel |
15.5 mm |
23 |
26 mm |
||||||||||||||||||||
|
KEMET Corporation |
SINGLE PHASE EMI FILTER |
1.8 A |
100 Mohm |
UL |
500 V |
TRAY |
THROUGH HOLE MOUNT |
250 V |
130 Cel |
-25 Cel |
15.5 mm |
23 |
26 mm |
||||||||||||||||||||
|
KEMET Corporation |
SINGLE PHASE EMI FILTER |
.8 A |
100 Mohm |
UL |
500 V |
TRAY |
THROUGH HOLE MOUNT |
250 V |
120 Cel |
-25 Cel |
21 mm |
13 |
23.5 mm |
||||||||||||||||||||
|
KEMET Corporation |
SINGLE PHASE EMI FILTER |
2 A |
100 Mohm |
UL |
TRAY |
THROUGH HOLE MOUNT |
250 V |
120 Cel |
-25 Cel |
12 mm |
14.5 |
18 mm |
|||||||||||||||||||||
|
KEMET Corporation |
|||||||||||||||||||||||||||||||||
Delta Electronics |
SINGLE PHASE EMI FILTER |
30 MHz |
10 A |
UL; CSA; VDE |
20 dB |
2250 V |
2 mA |
PANEL MOUNT |
250 V |
L64.52XB44.96XH29.97 (mm)/L2.54XB1.77XH1.18 (inch) |
45 dB |
10DBAG5 |
29.97 mm |
.15 MHz |
50/60Hz |
64.52 mm |
||||||||||||||||||
|
TE Connectivity |
SINGLE PHASE EMI FILTER |
10 MHz |
10 A |
UL; CSA; VDE |
5 dB |
2250 V |
.4 mA |
PANEL MOUNT |
250 V |
L85.1XB52.6XH38.9 (mm)/L3.35XB2.07XH1.53 (inch) |
40 Cel |
65 dB |
-10 Cel |
38.9 mm |
52.6 |
STUD TERMINAL |
.15 MHz |
50/60Hz |
85.1 mm |
||||||||||||||
|
TE Connectivity |
THREE PHASE EMI FILTER |
150 A |
6 Mohm |
CSA;UL |
2856 V |
8 mA |
PANEL MOUNT |
520 V |
85 Cel |
-25 Cel |
92 mm |
160 |
50/60Hz |
300 mm |
|||||||||||||||||||
|
TE Connectivity |
THREE PHASE EMI FILTER |
16 A |
6.9 mA |
PANEL MOUNT |
480 V |
40 Cel |
-10 Cel |
50Hz |
|||||||||||||||||||||||||
|
TE Connectivity |
SINGLE PHASE EMI FILTER |
20 A |
PANEL MOUNT |
40 Cel |
-10 Cel |
||||||||||||||||||||||||||||
|
TE Connectivity |
SINGLE PHASE EMI FILTER |
20 A |
40 Cel |
-10 Cel |
|||||||||||||||||||||||||||||
|
TE Connectivity |
SINGLE PHASE EMI FILTER |
20 A |
PANEL MOUNT |
40 Cel |
-10 Cel |
||||||||||||||||||||||||||||
|
TE Connectivity |
THREE PHASE EMI FILTER |
250 A |
UL |
2200 V |
270 mA |
PANEL MOUNT |
520 V |
50 Cel |
-10 Cel |
123 mm |
160 |
50-60Hz |
208 mm |
||||||||||||||||||||
|
Phoenix Contact |
SINGLE PHASE EMI FILTER |
1 A |
UL; IEC; VDE |
DIN RAIL MOUNT |
250 V |
L79.4XB25.0XH90.3 (mm)/L3.126XB0.984XH3.555 (inch) |
100 Cel |
-25 Cel |
90.3 mm |
25.0 |
79.4 mm |
EMI mains filters are electronic filters that are used to suppress electromagnetic interference (EMI) from mains power lines. They are designed to provide a high level of attenuation of unwanted frequencies while allowing the desired power signal to pass through with minimal distortion.
EMI mains filters use a combination of passive and active components, including capacitors, inductors, resistors, and diodes, to filter out noise and interference from power lines. They can be designed for a wide range of power ratings and frequencies, depending on the application.
EMI mains filters can be designed as low-pass filters, which allow low-frequency power signals to pass through while attenuating high-frequency EMI signals, or as band-stop filters, which block a specific range of frequencies while allowing other frequencies to pass through. They can also be designed with multiple stages of filtering to provide increased attenuation of unwanted frequencies.
EMI mains filters are commonly used in a variety of electronic systems, including power supplies, motor drives, medical equipment, and industrial control systems. They are also used in residential and commercial buildings to suppress EMI noise from power lines and prevent interference with other electronic devices.