HTFQFP Bus Controllers 11

Reset All
Part RoHS Manufacturer Peripheral IC Type Temperature Grade Terminal Form No. of Terminals Package Code Package Shape Package Body Material Surface Mount Maximum Supply Voltage Screening Level Address Bus Width No. of Bits DAC Channels Bit Size Power Supplies (V) Package Style (Meter) Package Equivalence Code Minimum Supply Voltage Maximum Operating Temperature CPU Family Maximum Data Transfer Rate Minimum Operating Temperature Terminal Finish ADC Channels Terminal Position DMA Channels Maximum Seated Height ROM Words Width Data EEPROM Size Additional Features Peripherals External Data Bus Width Maximum Clock Frequency Maximum Time At Peak Reflow Temperature (s) Peak Reflow Temperature (C) Length RAM Bytes Technology Maximum Supply Current Nominal Supply Voltage PWM Channels Sub-Category Connectivity ROM Programmability Bus Compatibility Terminal Pitch JESD-30 Code Moisture Sensitivity Level (MSL) Qualification Speed Drive Interface Standard JESD-609 Code On Chip Program ROM Width No. of I/O Lines

TUSB9261IPVP

Texas Instruments

BUS CONTROLLER, UNIVERSAL SERIAL BUS

INDUSTRIAL

GULL WING

64

HTFQFP

SQUARE

PLASTIC/EPOXY

YES

1.155 V

1.1,3.3

FLATPACK, HEAT SINK/SLUG, THIN PROFILE, FINE PITCH

TQFP64,.35SQ,16

1.045 V

85 Cel

375 MBps

-40 Cel

NICKEL PALLADIUM GOLD

QUAD

1.2 mm

7 mm

40 MHz

30

260

7 mm

CMOS

.005 mA

1.1 V

Bus Controllers

ATA; ATAPI

.4 mm

S-PQFP-G64

3

Not Qualified

IEEE 1149.6; IEEE 1149.1

e4

TUSB8041IPAPQ1

Texas Instruments

BUS CONTROLLER, UNIVERSAL SERIAL BUS

INDUSTRIAL

GULL WING

64

HTFQFP

SQUARE

PLASTIC/EPOXY

YES

1.26 V

AEC-Q100

FLATPACK, HEAT SINK/SLUG, THIN PROFILE, FINE PITCH

.99 V

85 Cel

-40 Cel

NICKEL PALLADIUM GOLD

QUAD

1.2 mm

10 mm

24 MHz

30

260

10 mm

CMOS

1.1 V

I2C; SMBUS

.5 mm

S-PQFP-G64

3

e4

TUSB8041IPAPRQ1

Texas Instruments

BUS CONTROLLER, UNIVERSAL SERIAL BUS

INDUSTRIAL

GULL WING

64

HTFQFP

SQUARE

PLASTIC/EPOXY

YES

1.26 V

AEC-Q100

FLATPACK, HEAT SINK/SLUG, THIN PROFILE, FINE PITCH

.99 V

85 Cel

-40 Cel

NICKEL PALLADIUM GOLD

QUAD

1.2 mm

10 mm

24 MHz

30

260

10 mm

CMOS

1.1 V

I2C; SMBUS

.5 mm

S-PQFP-G64

3

e4

TUSB9261IPAPQ1

Texas Instruments

BUS CONTROLLER, UNIVERSAL SERIAL BUS

INDUSTRIAL

GULL WING

64

HTFQFP

SQUARE

PLASTIC/EPOXY

YES

1.155 V

AEC-Q100

FLATPACK, HEAT SINK/SLUG, THIN PROFILE, FINE PITCH

1.045 V

85 Cel

375 MBps

-40 Cel

NICKEL PALLADIUM GOLD

QUAD

1.2 mm

10 mm

40 MHz

30

260

10 mm

CMOS

1.1 V

ATA

.5 mm

S-PQFP-G64

3

IEEE 1149.6; IEEE 1149.1

e4

TUSB9261PVP

Texas Instruments

BUS CONTROLLER, UNIVERSAL SERIAL BUS

COMMERCIAL

GULL WING

64

HTFQFP

SQUARE

PLASTIC/EPOXY

YES

1.155 V

0

1.1,3.3

FLATPACK, HEAT SINK/SLUG, THIN PROFILE, FINE PITCH

TQFP64,.35SQ,16

1.045 V

70 Cel

384 MBps

0 Cel

NICKEL PALLADIUM GOLD

QUAD

1.2 mm

7 mm

0

40 MHz

30

260

7 mm

CMOS

.005 mA

1.1 V

Bus Controllers

ATA; ATAPI

.4 mm

S-PQFP-G64

3

Not Qualified

IEEE 1149.6; IEEE 1149.1

e4

TUSB9261IPAPRQ1

Texas Instruments

BUS CONTROLLER, UNIVERSAL SERIAL BUS

INDUSTRIAL

GULL WING

64

HTFQFP

SQUARE

PLASTIC/EPOXY

YES

1.155 V

AEC-Q100

FLATPACK, HEAT SINK/SLUG, THIN PROFILE, FINE PITCH

1.045 V

85 Cel

375 MBps

-40 Cel

NICKEL PALLADIUM GOLD

QUAD

1.2 mm

10 mm

40 MHz

30

260

10 mm

CMOS

1.1 V

ATA

.5 mm

S-PQFP-G64

3

IEEE 1149.6; IEEE 1149.1

e4

TUSB8040PFP

Texas Instruments

BUS CONTROLLER, UNIVERSAL SERIAL BUS

COMMERCIAL

GULL WING

80

HTFQFP

SQUARE

PLASTIC/EPOXY

YES

1.155 V

0

1.1,3.3

FLATPACK, HEAT SINK/SLUG, THIN PROFILE, FINE PITCH

TQFP80,.55SQ

1.045 V

70 Cel

0 Cel

NICKEL PALLADIUM GOLD

QUAD

1.2 mm

12 mm

0

24 MHz

30

260

12 mm

CMOS

900 mA

1.1 V

Bus Controllers

I2C

.5 mm

S-PQFP-G80

3

Not Qualified

e4

PCI1410RFP

Texas Instruments

BUS CONTROLLER, PCMCIA

GULL WING

144

HTFQFP

SQUARE

PLASTIC/EPOXY

YES

0

FLATPACK

33 MBps

QUAD

1.2 mm

20 mm

OPERATES WITH 5 V NOMINAL SUPPLY

0

20 mm

CMOS

3.3 V

.5 mm

S-PQFP-G144

Not Qualified

TUSB8040PFPR

Texas Instruments

BUS CONTROLLER, UNIVERSAL SERIAL BUS

COMMERCIAL

GULL WING

80

HTFQFP

SQUARE

PLASTIC/EPOXY

YES

1.26 V

FLATPACK, HEAT SINK/SLUG, THIN PROFILE, FINE PITCH

.99 V

70 Cel

0 Cel

QUAD

1.2 mm

12 mm

1.05-V SUPPLY MAY BE USED AS LONG AS MINIMUM SUPPLY CONDITIONS ARE MET

24 MHz

12 mm

CMOS

1.1 V

I2C; SMBUS

.5 mm

S-PQFP-G80

TUSB8040PFPT

Texas Instruments

BUS CONTROLLER, UNIVERSAL SERIAL BUS

COMMERCIAL

GULL WING

80

HTFQFP

SQUARE

PLASTIC/EPOXY

YES

1.26 V

FLATPACK, HEAT SINK/SLUG, THIN PROFILE, FINE PITCH

.99 V

70 Cel

0 Cel

QUAD

1.2 mm

12 mm

1.05-V SUPPLY MAY BE USED AS LONG AS MINIMUM SUPPLY CONDITIONS ARE MET

24 MHz

12 mm

CMOS

1.1 V

I2C; SMBUS

.5 mm

S-PQFP-G80

PEX8603-AB50TQIG

Broadcom

BUS CONTROLLER, PCI

INDUSTRIAL

GULL WING

128

HTFQFP

SQUARE

PLASTIC/EPOXY

YES

1.1 V

0

FLATPACK, HEAT SINK/SLUG, THIN PROFILE, FINE PITCH

TQFP128(UNSPEC)

.95 V

85 Cel

-40 Cel

MATTE TIN

QUAD

1.2 mm

14 mm

0

260

14 mm

CMOS

1 V

Bus Controllers

I2C; ISA; SMBUS; SPI; VGA

.4 mm

S-PQFP-G128

3

Not Qualified

e3

Bus Controllers

Bus controllers are integrated circuits that are used to manage and control the flow of data and control signals between different devices in a computer system. They are commonly used in systems that have multiple buses, such as a memory bus and an I/O bus. Bus controllers ensure that data is transferred efficiently and correctly between different devices in the system.

One of the primary functions of a bus controller is to manage bus arbitration. Bus arbitration is the process of resolving conflicts that occur when two or more devices on the bus attempt to access the bus at the same time. Bus controllers use various algorithms to determine which device has priority access to the bus and when other devices can access it.

Another important function of bus controllers is to manage the transfer of data and control signals between devices on the bus. This involves controlling the timing and synchronization of signals, as well as error detection and correction. Bus controllers also manage other aspects of the bus, such as interrupt handling and power management.