Panasonic Power & Signal Relays 583

Reset All
Part RoHS Manufacturer Relay Type Mounting Feature Relay Action Relay Function Coil or Input Supply Type Reference Standard Maximum Contact AC Rating (R Load) Dielectric Strength Between Open Contacts AC Coil Release Voltage Relay Form AC Coil Operate Voltage Operate Time Maximum Contact AC Rating (M Load) Electrical Life Maximum Contact DC Power Rating (R Load) Release Time Insulation Resistance Coil Power (mW) Packing Method Body Length/Diameter Body Width Coil Resistance Sealing Weight Maximum AC Coil Current No. of Terminals Physical Dimension End Contact Plating Body Height Dielectric Strength Between Coil & Contacts Maximum Contact DC Rating (R Load) Maximum Operating Temperature Maximum AC Contact Current Maximum DC Coil Current Maximum AC Coil Voltage Maximum Contact AC Rating (I Load) Minimum Operating Temperature DC Coil Release Voltage Terminal Finish Maximum DC Contact Current Termination Type Maximum Contact AC Power Rating (M Load) Nominal Coil Voltage DC Coil Operate Voltage Manufacturer Series Contact Resistance Input Switching Control Type End Contact Material PCB Hole Count Maximum DC Contact Voltage Additional Features Maximum AC Contact Voltage JESD-609 Code Minimum Operating Frequency Terminal Length Maximum DC Coil Voltage Maximum Operating Frequency Maximum Contact AC Power Rating (R Load) Contact or Output Supply Type

HP3-DC110V

Panasonic

Power/Signal Relay

Panel Mount

Momentary

3PDT

DC

CSA; UL

10A@250VAC

30 ms

200000 Cycle(s)

30 ms

1.6 W

Box

1.496 in (38 mm)

36 in (914.4 mm)

7.45 kΩ

1.496 x 1.417 x 1.929 in (38 x 36 x 49 mm)

1.929 in (49 mm)

40 °C (104 °F)

10 A

15 mA

-50 °C (-58 °F)

16.5 V

Quick Connect

88 V

HP

250 V

110 V

AC

HY1Z-12V

Panasonic

Power/Signal Relay

Through Hole-Straight Mount

Momentary

SPDT

DC

CSA; UL

5 ms

100000 Cycle(s)

4 ms

200 mW

Box; Tube

0.472 in (12 mm)

7.4 in (187.96 mm)

720 Ω

0.472 x 0.291 x 0.398 in (12 x 7.4 x 10.1 mm)

0.398 in (10.1 mm)

1A@30VDC

70 °C (158 °F)

17 mA

-40 °C (-40 °F)

1.2 V

Silver/Gold

1 A

Solder

9 V

30 V

12 V

DC

JQ1P-24V-F

Panasonic

Power/Signal Relay

Through Hole-Straight Mount

Momentary

SPDT

DC

CSA; SEMKO; TUV; UL; VDE

3A@250VAC

20 ms

100000 Cycle(s)

10 ms

400 mW

Box

0.787 in (20 mm)

10 in (254 mm)

1.44 kΩ

0.787 x 0.394 x 0.63 in (20 x 10 x 16 mm)

0.63 in (16 mm)

3A@110VDC

85 °C (185 °F)

3 A

17 mA

-40 °C (-40 °F)

1.2 V

3 A

Solder

19.2 V

110 V

250 V

24 V

AC/DC

S2-DC24V

Panasonic

Power/Signal Relay

Through Hole-Straight Mount

Momentary

4PST

DC

CSA; UL

4A@250VAC

750 Vrms

2 Form A, B

15 ms

100000 Cycle(s)

10 ms

10 GΩ

202 mW

Box; Tube

1.102 in (28 mm)

12 in (304.8 mm)

2.85 kΩ

8 g

12

1.102 x 0.472 x 0.394 in (28 x 12 x 10 mm)

Gold

0.394 in (10 mm)

1.5 kVrms

3A@48VDC

65 °C (149 °F)

4 A

-55 °C (-67 °F)

2.4 V

3 A

Solder

24 V

16.8 V

Random

Silver Alloy

12

48 V

Socket Mount also available

250 V

0.1575 in (4 mm)

44 V

AC/DC

TQ2SS-L2-12V

Panasonic

Power/Signal Relay

Surface Mount-Straight

Latched

DPDT

DC

CSA; UL

2A@125VAC

4 ms

100000 Cycle(s)

4 ms

140 mW

Tube

0.551 in (14 mm)

9 in (228.6 mm)

1.028 kΩ

0.551 x 0.354 x 0.213 in (14 x 9 x 5.4 mm)

0.213 in (5.4 mm)

2A@220VDC

70 °C (158 °F)

2 A

12 mA

-40 °C (-40 °F)

9 V

2 A

Solder

9 V

220 V

Low Profile

125 V

12 V

AC/DC

VC20-3A-AC120V-K

Panasonic

Power/Signal Relay

Panel Mount

Momentary

3PST

AC

3A@300VAC

30 ms

250000 Cycle(s)

30 ms

7.2 W

Bulk

2.047 in (52 mm)

30 in (762 mm)

60 mA

2.047 x 1.181 x 2.146 in (52 x 30 x 54.5 mm)

2.146 in (54.5 mm)

40 °C (104 °F)

3 A

120 V

-10 °C (14 °F)

Quick Connect

VC

Coil Operate Voltage (AC): 96 V, Coil Release Voltage (AC): 24 V

300 V

AC

NR-SD-12V

Panasonic

Power/Signal Relay

Through Hole-Straight Mount

Momentary

SPDT

DC

0.3A@110VAC

1 Form C

3.5 ms

20W@30VDC

2.5 ms

1 GΩ

162 mW

Box

0.787 in (20 mm)

10 in (254 mm)

890 Ω

8

0.787 x 0.394 x 0.394 in (20 x 10 x 10 mm)

0.394 in (10 mm)

1A@30VDC

65 °C (149 °F)

300 mA

14 mA

-55 °C (-67 °F)

1.2 V

1 A

Solder

12 V

9.3 V

60 mΩ

Random

Gold Cobalt

30 V

110 V

0.1575 in (4 mm)

28 V

33VA@110VAC

AC/DC

Power & Signal Relays

Power and signal relays are electromechanical switches that are used to control power circuits and signal circuits respectively. Power relays are designed to handle higher voltages and currents, typically in the range of several hundred volts and amperes. They are commonly used in industrial and automotive applications to switch on/off motors, heaters, lights, and other high-power loads. Signal relays, on the other hand, are designed to handle lower voltages and currents, typically in the range of several volts and milliamperes. They are commonly used in electronic equipment such as computers, telecommunications equipment, and consumer electronics to switch on/off signals, data, and low-power loads.

Power and signal relays come in different types and configurations depending on the specific application requirements. Some common types include electromechanical relays, reed relays, solid-state relays, and latching relays. Electromechanical relays use a mechanical switching mechanism, typically a set of contacts that move to make or break an electrical circuit. Reed relays use a set of magnetically activated contacts that are enclosed in a sealed glass tube. Solid-state relays use a semiconductor device to switch on/off the load. Latching relays use a magnetic field to hold the contacts in either the open or closed position, eliminating the need for continuous power to maintain the relay's state.

Power and signal relays play a critical role in the overall performance and reliability of electrical and electronic systems. The selection of the appropriate relay for a given application is crucial to ensure proper operation, safety, and longevity of the system. Factors to consider when selecting a relay include the load current and voltage, switching frequency, contact rating, switching speed, contact bounce, and environmental conditions such as temperature, humidity, and vibration. Proper maintenance and testing of relays are also important to ensure their continued performance and reliability over time.