Phoenix Contact Power & Signal Relays 979

Reset All
Part RoHS Manufacturer Relay Type Mounting Feature Relay Action Relay Function Coil or Input Supply Type Reference Standard Maximum Contact AC Rating (R Load) Dielectric Strength Between Open Contacts AC Coil Release Voltage Relay Form AC Coil Operate Voltage Operate Time Maximum Contact AC Rating (M Load) Electrical Life Maximum Contact DC Power Rating (R Load) Release Time Insulation Resistance Coil Power (mW) Packing Method Body Length/Diameter Body Width Coil Resistance Sealing Weight Maximum AC Coil Current No. of Terminals Physical Dimension End Contact Plating Body Height Dielectric Strength Between Coil & Contacts Maximum Contact DC Rating (R Load) Maximum Operating Temperature Maximum AC Contact Current Maximum DC Coil Current Maximum AC Coil Voltage Maximum Contact AC Rating (I Load) Minimum Operating Temperature DC Coil Release Voltage Terminal Finish Maximum DC Contact Current Termination Type Maximum Contact AC Power Rating (M Load) Nominal Coil Voltage DC Coil Operate Voltage Manufacturer Series Contact Resistance Input Switching Control Type End Contact Material PCB Hole Count Maximum DC Contact Voltage Additional Features Maximum AC Contact Voltage JESD-609 Code Minimum Operating Frequency Terminal Length Maximum DC Coil Voltage Maximum Operating Frequency Maximum Contact AC Power Rating (R Load) Contact or Output Supply Type

2909654

Phoenix Contact

Power/Signal Relay

2961406

Phoenix Contact

Power/Signal Relay

PLC-RSC-12DC/21

Phoenix Contact

Power/Signal Relay

DIN Rail Mount

Momentary

SPDT

DC

CUL; EAC; EN; GL; IEC; PRS; RC FRT; UL

3A@230VAC

5 ms

8 ms

180 mW

Bulk

3.701 in (94 mm)

6.2 in (157.48 mm)

800 Ω

IP20; RT3

3.701 x 0.244 x 3.15 in (94 x 6.2 x 80 mm)

3.15 in (80 mm)

2A@24VDC

60 °C (140 °F)

3 A

15 mA

-40 °C (-40 °F)

2 A

Snap-On

24 V

230 V

12 V

AC/DC

PLC-RSC-24DC/21-21/EX

Phoenix Contact

Power/Signal Relay

PLC-RSC-24DC/21-21/MS

Phoenix Contact

Power/Signal Relay

PLC-RSC-24DC/21-21ATEX

Phoenix Contact

Power/Signal Relay

REL-MR-24DC/21

Phoenix Contact

Power/Signal Relay

REL-MR-24DC/21HC/MS

Phoenix Contact

Power/Signal Relay

Socket Mount

Momentary

SPDT

DC

CUL; DIN; EN; IEC; UL; VDE

9 ms

6 ms

432 mW

1.142 in (29 mm)

12.7 in (322.58 mm)

1.333 kΩ

1.142 x 0.5 x 0.984 in (29 x 12.7 x 25 mm)

0.984 in (25 mm)

70 °C (158 °F)

18 mA

-40 °C (-40 °F)

Snap-On

250 V

LED Indicator and Diode with Test Button

250 V

24 V

RIF-1-RPT-LDP-24DC/2X21

Phoenix Contact

Power/Signal Relay

2903667

Phoenix Contact

Power/Signal Relay

2903667

PLC-RPT-24DC/21-21AU/MS

Phoenix Contact

Power/Signal Relay

RIF-1-RPT-LDP-24DC/2X21MS

Phoenix Contact

Power/Signal Relay

2900304

Phoenix Contact

Power/Signal Relay

2900304

2961150

Phoenix Contact

Power/Signal Relay

Through Hole-Straight Mount

Momentary

SPDT

DC

CSA; UL; VDE

6A@250VAC

5 ms

2.5 ms

Bulk

1.102 in (28 mm)

5 in (127 mm)

1.102 x 0.197 x 0.591 in (28 x 5 x 15 mm)

0.591 in (15 mm)

6A@250VDC

85 °C (185 °F)

6 A

14 mA

-40 °C (-40 °F)

6 A

Solder

2961150

250 V

250 V

12 V

AC/DC

2700581

Phoenix Contact

Power/Signal Relay

RIF-0-RPT-24DC/1

Phoenix Contact

Power/Signal Relay

DIN Rail Mount

Momentary

SPST

DC

DNV GL; DIN EN 50178; EAC; LR; PRS: UL

3A@250VAC

1 Form A

5 ms

8 ms

216 mW

Bulk

3.661 in (93 mm)

6.2 in (157.48 mm)

2.667 kΩ

IP20; RT3

24.95 g

3.661 x 0.244 x 2.598 in (93 x 6.2 x 66 mm)

2.598 in (66 mm)

3A@250VDC

60 °C (140 °F)

9 mA

-40 °C (-40 °F)

3 A

24 V

Random

250 V

250 V

AC/DC

2909642

Phoenix Contact

Power/Signal Relay

2964500

Phoenix Contact

Power/Signal Relay

DIN Rail Mount

Momentary

SPDT

DC

CUL; DIN EN 50178; EAC; IEC 60664; UL; VDE

3A@230VAC

1 Form C

8 ms

140W@24VDC

5 ms

220 mW

Bulk

3.15 in (80 mm)

6.2 in (157.48 mm)

2.667 kΩ

IP67

3.15 x 0.244 x 2.205 in (80 x 6.2 x 56 mm)

2.205 in (56 mm)

2A@24VDC

50 °C (122 °F)

3 A

9 mA

-20 °C (-4 °F)

2 A

24 V

Random

Silver Tin Oxide

24 V

With Diode and LED Indication

230 V

26.4 V

1500VA@250VAC

AC/DC

2900316

Phoenix Contact

Power/Signal Relay

2900316

2981978

Phoenix Contact

Power/Signal Relay

DIN Rail Mount

Momentary

DC

CUL; UL

5A@250VAC

50 ms

50 ms

3.898 in (99 mm)

17.5 in (444.5 mm)

3.898 x 0.689 x 4.508 in (99 x 17.5 x 114.5 mm)

Gold

4.508 in (114.5 mm)

5A@250VDC

85 °C (185 °F)

5 A

55 mA

-20 °C (-4 °F)

5 A

24 V

Silver Copper Nickel Alloy

250 V

250 V

1250VA@250VAC

AC/DC

2903306

Phoenix Contact

Power/Signal Relay

2903526

Phoenix Contact

Power/Signal Relay

2866077

Phoenix Contact

Power/Signal Relay

2903677

Phoenix Contact

Power/Signal Relay

2903693

Phoenix Contact

Power/Signal Relay

2903693

PLC-RSC-24DC/21

Phoenix Contact

Power/Signal Relay

DIN Rail Mount

Momentary

SPDT

DC

CUL; EAC; EN; DNV GL; IEC 60664; PRS; RC FRT; UL

5 ms

8 ms

220 mW

Bulk

3.701 in (94 mm)

6.2 in (157.48 mm)

2.667 kΩ

IP20; RT3

3.701 x 0.244 x 3.15 in (94 x 6.2 x 80 mm)

3.15 in (80 mm)

60 °C (140 °F)

9 mA

-40 °C (-40 °F)

24 V

Random

Silver Tin Oxide

250 V

250 V

AC/DC

RIF-2-RPT-LDP-24DC/2X21

Phoenix Contact

Power/Signal Relay

2900310

Phoenix Contact

Power/Signal Relay

Gold

e4

2903361

Phoenix Contact

Power/Signal Relay

DIN Rail Mount

Momentary

SPST

DC

DNV GL; DIN EN 50178; EAC; LR; PRS: UL

3A@250VAC

1 Form A

5 ms

8 ms

216 mW

Bulk

3.661 in (93 mm)

6.2 in (157.48 mm)

2.667 kΩ

IP20; RT3

24.95 g

3.661 x 0.244 x 2.598 in (93 x 6.2 x 66 mm)

2.598 in (66 mm)

3A@250VDC

60 °C (140 °F)

9 mA

-40 °C (-40 °F)

3 A

24 V

Random

250 V

250 V

AC/DC

2903367

Phoenix Contact

Power/Signal Relay

2903670

Phoenix Contact

Power/Signal Relay

2903688

Phoenix Contact

Power/Signal Relay

2903688

2961257

Phoenix Contact

Power/Signal Relay

2961338

Phoenix Contact

Power/Signal Relay

2987972

Phoenix Contact

Power/Signal Relay

2903317

Phoenix Contact

Power/Signal Relay

2903365

Phoenix Contact

Power/Signal Relay

2903660

Phoenix Contact

Power/Signal Relay

2903660

2903702

Phoenix Contact

Power/Signal Relay

2903702

2906224

Phoenix Contact

Power/Signal Relay

2908047

Phoenix Contact

Power/Signal Relay

2940391

Phoenix Contact

Power/Signal Relay

2961202

Phoenix Contact

Power/Signal Relay

2961215

Phoenix Contact

Power/Signal Relay

Through Hole-Straight Mount

Momentary

DPDT

DC

CUL; EAC; EN; GL; IEC; PRS; UL; VDE

7 ms

3 ms

410 mW

Bulk

1.142 in (29 mm)

12.7 in (322.58 mm)

1.44 kΩ

RT3

1.142 x 0.5 x 0.618 in (29 x 12.7 x 15.7 mm)

0.618 in (15.7 mm)

85 °C (185 °F)

17 mA

-40 °C (-40 °F)

Gold

Solder

36 V

Socket Mountable

30 V

e4

24 V

2980461

Phoenix Contact

Power/Signal Relay

2987338

Phoenix Contact

Power/Signal Relay

REL-IR4/LDP-24DC/4X21AU

Phoenix Contact

Power/Signal Relay

PR1-RSC3-LV-120AC/2X21AU

Phoenix Contact

Power/Signal Relay

Power & Signal Relays

Power and signal relays are electromechanical switches that are used to control power circuits and signal circuits respectively. Power relays are designed to handle higher voltages and currents, typically in the range of several hundred volts and amperes. They are commonly used in industrial and automotive applications to switch on/off motors, heaters, lights, and other high-power loads. Signal relays, on the other hand, are designed to handle lower voltages and currents, typically in the range of several volts and milliamperes. They are commonly used in electronic equipment such as computers, telecommunications equipment, and consumer electronics to switch on/off signals, data, and low-power loads.

Power and signal relays come in different types and configurations depending on the specific application requirements. Some common types include electromechanical relays, reed relays, solid-state relays, and latching relays. Electromechanical relays use a mechanical switching mechanism, typically a set of contacts that move to make or break an electrical circuit. Reed relays use a set of magnetically activated contacts that are enclosed in a sealed glass tube. Solid-state relays use a semiconductor device to switch on/off the load. Latching relays use a magnetic field to hold the contacts in either the open or closed position, eliminating the need for continuous power to maintain the relay's state.

Power and signal relays play a critical role in the overall performance and reliability of electrical and electronic systems. The selection of the appropriate relay for a given application is crucial to ensure proper operation, safety, and longevity of the system. Factors to consider when selecting a relay include the load current and voltage, switching frequency, contact rating, switching speed, contact bounce, and environmental conditions such as temperature, humidity, and vibration. Proper maintenance and testing of relays are also important to ensure their continued performance and reliability over time.