Part RoHS Manufacturer Relay Type Mounting Feature Relay Action Relay Function Coil or Input Supply Type Reference Standard Maximum Contact AC Rating (R Load) Dielectric Strength Between Open Contacts AC Coil Release Voltage Relay Form AC Coil Operate Voltage Operate Time Electrical Life Release Time Insulation Resistance Coil Power (mW) Packing Method Body Length/Diameter Body Width Coil Resistance Sealing Weight Maximum AC Coil Current No. of Terminals Physical Dimension End Contact Plating Body Height Dielectric Strength Between Coil & Contacts Maximum Contact DC Rating (R Load) Maximum Operating Temperature Maximum AC Contact Current Maximum DC Coil Current Maximum AC Coil Voltage Minimum Operating Temperature DC Coil Release Voltage Terminal Finish Maximum DC Contact Current Termination Type Nominal Coil Voltage DC Coil Operate Voltage Manufacturer Series Contact Resistance Input Switching Control Type End Contact Material PCB Hole Count Maximum DC Contact Voltage Additional Features Maximum AC Contact Voltage JESD-609 Code Terminal Length Maximum DC Coil Voltage Contact or Output Supply Type

84871034

Crouzet

Monitoring Relay

DIN-Rail Mount

Momentary

SPST

AC

CSA; IEC; UL

8A@250VAC

500 ms

6000 Cycle(s)

500 ms

2.55 W

3.071 in (78 mm)

22.5 in (571.5 mm)

IP20; IP50; Moisture Proof

11 mA

3.071 x 0.886 x 3.937 in (78 x 22.5 x 100 mm)

3.937 in (100 mm)

50 °C (122 °F)

8 A

230 V

-20 °C (-4 °F)

Snap-on

250 V

Coil Operate Voltage (AC): 195.5 V

250 V

AC

2981499

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

UL

6A@250VAC

20 ms

10 ms

1.68 W

Bulk

4.508 in (114.5 mm)

22.5 in (571.5 mm)

IP20; IP54

4.508 x 0.886 x 4.409 in (114.5 x 22.5 x 112 mm)

4.409 in (112 mm)

6A@250VDC

55 °C (131 °F)

6 A

70 mA

-20 °C (-4 °F)

6 A

Connector

250 V

250 V

24 V

AC/DC

2981486

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

UL

6A@250VAC

20 ms

10 ms

1.68 W

Bulk

4.508 in (114.5 mm)

22.5 in (571.5 mm)

IP20; IP54

4.508 x 0.886 x 3.898 in (114.5 x 22.5 x 99 mm)

3.898 in (99 mm)

6A@250VDC

55 °C (131 °F)

6 A

70 mA

-20 °C (-4 °F)

6 A

Connector

250 V

250 V

24 V

AC/DC

2981538

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

TUV; UL

5A@250VAC

15 ms

12 ms

2.4 W

Bulk

4.508 in (114.5 mm)

45 in (1143 mm)

IP20; IP54

4.508 x 1.772 x 3.898 in (114.5 x 45 x 99 mm)

3.898 in (99 mm)

5A@250VDC

55 °C (131 °F)

5 A

100 mA

-20 °C (-4 °F)

Gold

5 A

Connector

250 V

250 V

e4

24 V

AC/DC

2981567

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

TUV; UL

5A@250VAC

12 ms

8 ms

1.44 W

Bulk

4.508 in (114.5 mm)

22.5 in (571.5 mm)

IP20; IP54

4.508 x 0.886 x 3.898 in (114.5 x 22.5 x 99 mm)

3.898 in (99 mm)

5A@250VDC

55 °C (131 °F)

5 A

60 mA

-20 °C (-4 °F)

Gold

5 A

Connector

2981567

250 V

250 V

e4

24 V

AC/DC

2981114

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

AC/DC

TUV; UL

6A@250VAC

60 ms

20 ms

2.88 W

Bulk

4.508 in (114.5 mm)

45 in (1143 mm)

IP20; IP54

25 mA

4.508 x 1.772 x 3.898 in (114.5 x 45 x 99 mm)

3.898 in (99 mm)

6A@250VDC

55 °C (131 °F)

6 A

120 mA

230 V

-20 °C (-4 °F)

6 A

Connector

250 V

250 V

24 V

AC/DC

2981512

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

UL

6A@250VAC

20 ms

38 s

2.256 W

Bulk

4.508 in (114.5 mm)

22.5 in (571.5 mm)

IP20; IP54

4.508 x 0.886 x 3.898 in (114.5 x 22.5 x 99 mm)

3.898 in (99 mm)

6A@250VDC

55 °C (131 °F)

6 A

94 mA

-20 °C (-4 °F)

6 A

Connector

250 V

250 V

24 V

AC/DC

2981680

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

UL

6A@250VAC

10 ms

10 ms

2.4 W

Bulk

4.508 in (114.5 mm)

22.5 in (571.5 mm)

IP20; IP54

4.508 x 0.886 x 4.409 in (114.5 x 22.5 x 112 mm)

4.409 in (112 mm)

6A@250VDC

55 °C (131 °F)

6 A

100 mA

-20 °C (-4 °F)

6 A

Connector

250 V

250 V

24 V

AC/DC

2981127

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

AC/DC

TUV; UL

6A@250VAC

60 ms

20 ms

2.88 W

Bulk

4.508 in (114.5 mm)

45 in (1143 mm)

IP20; IP54

25 mA

4.508 x 1.772 x 4.409 in (114.5 x 45 x 112 mm)

4.409 in (112 mm)

6A@250VDC

55 °C (131 °F)

6 A

120 mA

230 V

-20 °C (-4 °F)

6 A

Connector

250 V

250 V

24 V

AC/DC

2981541

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

TUV; UL

5A@250VAC

15 ms

12 ms

2.4 W

Bulk

4.508 in (114.5 mm)

45 in (1143 mm)

IP20; IP54

4.508 x 1.772 x 4.409 in (114.5 x 45 x 112 mm)

4.409 in (112 mm)

5A@250VDC

55 °C (131 °F)

5 A

100 mA

-20 °C (-4 °F)

Gold

5 A

Connector

2981541

250 V

250 V

e4

24 V

AC/DC

2981570

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

TUV; UL

5A@250VAC

12 ms

8 ms

1.44 W

Bulk

4.508 in (114.5 mm)

22.5 in (571.5 mm)

IP20; IP54

4.508 x 0.886 x 4.409 in (114.5 x 22.5 x 112 mm)

4.409 in (112 mm)

5A@250VDC

55 °C (131 °F)

5 A

60 mA

-20 °C (-4 °F)

Gold

5 A

Connector

2981570

250 V

250 V

e4

24 V

AC/DC

2981745

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

UL

6A@250VAC

20 ms

300 ms

2.256 W

Bulk

4.508 in (114.5 mm)

22.5 in (571.5 mm)

IP20; IP54

4.508 x 0.886 x 4.409 in (114.5 x 22.5 x 112 mm)

4.409 in (112 mm)

6A@250VDC

55 °C (131 °F)

6 A

94 mA

-20 °C (-4 °F)

6 A

Connector

250 V

250 V

24 V

AC/DC

2981677

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

UL

6A@250VAC

10 ms

10 ms

2.4 W

Bulk

4.508 in (114.5 mm)

22.5 in (571.5 mm)

IP20; IP54

4.508 x 0.886 x 3.898 in (114.5 x 22.5 x 99 mm)

3.898 in (99 mm)

6A@250VDC

55 °C (131 °F)

6 A

100 mA

-20 °C (-4 °F)

6 A

Connector

2981677

250 V

250 V

24 V

AC/DC

2981732

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

UL

6A@250VAC

20 ms

300 ms

2.256 W

Bulk

4.508 in (114.5 mm)

22.5 in (571.5 mm)

IP20; IP54

4.508 x 0.886 x 3.898 in (114.5 x 22.5 x 99 mm)

3.898 in (99 mm)

6A@250VDC

55 °C (131 °F)

6 A

94 mA

-20 °C (-4 °F)

6 A

Connector

250 V

250 V

24 V

AC/DC

2981729

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

UL

6A@250VAC

20 ms

2 s

2.016 W

Bulk

4.508 in (114.5 mm)

22.5 in (571.5 mm)

IP20; IP54

4.508 x 0.886 x 4.409 in (114.5 x 22.5 x 112 mm)

4.409 in (112 mm)

6A@250VDC

55 °C (131 °F)

6 A

84 mA

-20 °C (-4 °F)

6 A

Connector

2981729

250 V

250 V

24 V

AC/DC

2981703

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

UL

6A@250VAC

20 ms

2 s

2.016 W

Bulk

4.508 in (114.5 mm)

22.5 in (571.5 mm)

IP20; IP54

4.508 x 0.886 x 3.898 in (114.5 x 22.5 x 99 mm)

3.898 in (99 mm)

6A@250VDC

55 °C (131 °F)

6 A

84 mA

-20 °C (-4 °F)

6 A

Connector

250 V

250 V

24 V

AC/DC

2981525

Phoenix Contact

Safety Relay

DIN-Rail Mount

Momentary

SPST

DC

UL

6A@250VAC

20 ms

38 s

2.256 W

Bulk

4.508 in (114.5 mm)

22.5 in (571.5 mm)

IP20; IP54

4.508 x 0.886 x 4.409 in (114.5 x 22.5 x 112 mm)

4.409 in (112 mm)

6A@250VDC

55 °C (131 °F)

6 A

94 mA

-20 °C (-4 °F)

6 A

Connector

2981525

250 V

250 V

24 V

AC/DC

Special Function Relays

Special function relays are a type of electrical switch that can perform a specific function based on their design and construction. They are designed for specific applications that require unique features such as high voltage or current capacity, high-speed switching, or low power consumption.

Some examples of special function relays include time delay relays, latching relays, safety relays, and solid-state relays. Time delay relays are used to control the timing of circuits or processes and can be programmed to switch on or off after a certain amount of time. Latching relays, on the other hand, require a pulse of current to switch on and remain on even after the pulse is removed until a reset pulse is applied.

Safety relays are designed to interrupt power to a machine or process when a safety interlock is activated, helping to prevent accidents or injuries. Solid-state relays use electronic components such as transistors and diodes to switch high loads and are preferred in applications that require high speed, low noise, and long life.