Part | RoHS | Manufacturer | Relay Type | Mounting Feature | Relay Action | Relay Function | Coil or Input Supply Type | Reference Standard | Maximum Contact AC Rating (R Load) | Dielectric Strength Between Open Contacts | AC Coil Release Voltage | Relay Form | AC Coil Operate Voltage | Operate Time | Electrical Life | Release Time | Insulation Resistance | Coil Power (mW) | Packing Method | Body Length/Diameter | Body Width | Coil Resistance | Sealing | Weight | Maximum AC Coil Current | No. of Terminals | Physical Dimension | End Contact Plating | Body Height | Dielectric Strength Between Coil & Contacts | Maximum Contact DC Rating (R Load) | Maximum Operating Temperature | Maximum AC Contact Current | Maximum DC Coil Current | Maximum AC Coil Voltage | Minimum Operating Temperature | DC Coil Release Voltage | Terminal Finish | Maximum DC Contact Current | Termination Type | Nominal Coil Voltage | DC Coil Operate Voltage | Manufacturer Series | Contact Resistance | Input Switching Control Type | End Contact Material | PCB Hole Count | Maximum DC Contact Voltage | Additional Features | Maximum AC Contact Voltage | JESD-609 Code | Terminal Length | Maximum DC Coil Voltage | Contact or Output Supply Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Crouzet |
Monitoring Relay |
DIN-Rail Mount |
Momentary |
SPST |
AC |
CSA; IEC; UL |
8A@250VAC |
500 ms |
6000 Cycle(s) |
500 ms |
2.55 W |
3.071 in (78 mm) |
22.5 in (571.5 mm) |
IP20; IP50; Moisture Proof |
11 mA |
3.071 x 0.886 x 3.937 in (78 x 22.5 x 100 mm) |
3.937 in (100 mm) |
50 °C (122 °F) |
8 A |
230 V |
-20 °C (-4 °F) |
Snap-on |
250 V |
Coil Operate Voltage (AC): 195.5 V |
250 V |
AC |
|||||||||||||||||||||||||||
|
Phoenix Contact |
Monitoring Relay |
DIN-Rail Mount |
Momentary |
AC/DC |
CUL; EAC; TUV; UL |
6A@250VAC |
20.4 V |
20 ms |
45 ms |
1.56 W |
Bulk |
3.898 in (99 mm) |
22.5 in (571.5 mm) |
IP20; IP54 |
193 g |
140 mA |
8 |
3.898 x 0.886 x 4.508 in (99 x 22.5 x 114.5 mm) |
4.508 in (114.5 mm) |
55 °C (131 °F) |
6 A |
65 mA |
26.4 V |
-20 °C (-4 °F) |
6 A |
Snap-on |
24 V |
20.4 V |
Silver Tin Oxide |
250 V |
With LED, Surge Protection Suppressor Diode |
250 V |
26.4 V |
AC/DC |
|||||||||||||||||||
|
Siemens |
Monitoring Relay |
DIN-Rail Mount |
Change-Over |
AC/DC |
CCC; CE; EAC; RCM; UL |
1 Form C |
20.4 V |
3.622 in (92 mm) |
22.5 in (571.5 mm) |
IP20 |
3.622 x 0.886 x 3.583 in (92 x 22.5 x 91 mm) |
3.583 in (91 mm) |
27.6 V |
Snap-on |
24 V |
20.4 V |
27.6 V |
||||||||||||||||||||||||||||||||||||
|
Siemens |
Monitoring Relay |
DIN-Rail Mount |
SPDT |
CCC; CE; CSA; C-TICK; EAC; UL |
100000 Cycle(s) |
3.098 in (78.7 mm) |
45 in (1143 mm) |
IP20 |
3.098 x 1.772 x 3.256 in (78.7 x 45 x 82.7 mm) |
3.256 in (82.7 mm) |
60 °C (140 °F) |
-25 °C (-13 °F) |
Snap-on |
||||||||||||||||||||||||||||||||||||||||
|
Crouzet |
Monitoring Relay |
DIN-Rail Mount |
Momentary |
DPDT |
CE; CSA; GL; IEC; UL |
5A@250VAC |
500 ms |
100000 Cycle(s) |
1.5 s |
3.543 in (90 mm) |
35 in (889 mm) |
IP20; IP30; Moisture Proof |
3.543 x 1.378 x 2.579 in (90 x 35 x 65.5 mm) |
2.579 in (65.5 mm) |
5A@250VDC |
50 °C (122 °F) |
5 A |
-20 °C (-4 °F) |
5 A |
Snap-on |
250 V |
250 V |
AC/DC |
||||||||||||||||||||||||||||||
|
Phoenix Contact |
Monitoring Relay |
DIN-Rail Mount |
Momentary |
AC/DC |
CUL; EAC; TUV; UL |
6A@250VAC |
20.4 V |
100 ms |
45 ms |
1.56 W |
Bulk |
3.898 in (99 mm) |
22.5 in (571.5 mm) |
IP20; IP54 |
221.2 g |
140 mA |
8 |
3.898 x 0.886 x 4.508 in (99 x 22.5 x 114.5 mm) |
4.508 in (114.5 mm) |
55 °C (131 °F) |
6 A |
65 mA |
26.4 V |
-20 °C (-4 °F) |
6 A |
Snap-on |
24 V |
20.4 V |
Silver Tin Oxide |
250 V |
With LED, Surge Protection Suppressor Diode |
250 V |
26.4 V |
AC/DC |
|||||||||||||||||||
Carlo Gavazzi Holding Ag |
Monitoring Relay |
DIN-Rail Mount |
Momentary |
DPDT |
AC |
CE; CSA; EN; GL; UL |
8A@250VAC |
2 Form C |
100000 Cycle(s) |
3.287 in (83.5 mm) |
45 in (1143 mm) |
IP20 |
3.287 x 1.772 x 3.917 in (83.5 x 45 x 99.5 mm) |
3.917 in (99.5 mm) |
5A@24VDC |
60 °C (140 °F) |
8 A |
480 V |
-20 °C (-4 °F) |
5 A |
Snap-on |
Random |
Silver Tin Oxide |
24 V |
250 V |
AC/DC |
||||||||||||||||||||||||||||
|
Phoenix Contact |
Monitoring Relay |
DIN-Rail Mount |
Momentary |
AC/DC |
CUL; EAC; TUV; UL |
6A@250VAC |
20.4 V |
100 ms |
45 ms |
1.56 W |
Bulk |
3.898 in (99 mm) |
22.5 in (571.5 mm) |
IP20; IP54 |
221.2 g |
140 mA |
8 |
3.898 x 0.886 x 4.508 in (99 x 22.5 x 114.5 mm) |
4.508 in (114.5 mm) |
55 °C (131 °F) |
6 A |
65 mA |
26.4 V |
-20 °C (-4 °F) |
6 A |
Snap-on |
24 V |
20.4 V |
Silver Tin Oxide |
250 V |
With LED, Surge Protection Suppressor Diode |
250 V |
26.4 V |
AC/DC |
|||||||||||||||||||
|
Phoenix Contact |
Monitoring Relay |
DIN-Rail Mount |
DPDT |
CE; CUL; EAC; UL |
Bulk |
4.449 in (113 mm) |
22.5 in (571.5 mm) |
4.449 x 0.886 x 3.543 in (113 x 22.5 x 90 mm) |
3.543 in (90 mm) |
70 °C (158 °F) |
-25 °C (-13 °F) |
Snap-on |
With Fuse |
400 V |
|||||||||||||||||||||||||||||||||||||||
|
Phoenix Contact |
Monitoring Relay |
DIN-Rail Mount |
Momentary |
AC/DC |
CUL; EAC; TUV; UL |
6A@250VAC |
20.4 V |
20 ms |
45 ms |
1.56 W |
Bulk |
3.898 in (99 mm) |
22.5 in (571.5 mm) |
IP20; IP54 |
193 g |
140 mA |
8 |
3.898 x 0.886 x 4.508 in (99 x 22.5 x 114.5 mm) |
4.508 in (114.5 mm) |
55 °C (131 °F) |
6 A |
65 mA |
26.4 V |
-20 °C (-4 °F) |
6 A |
Snap-on |
24 V |
20.4 V |
Silver Tin Oxide |
250 V |
With LED, Surge Protection Suppressor Diode |
250 V |
26.4 V |
AC/DC |
|||||||||||||||||||
|
Phoenix Contact |
Monitoring Relay |
DIN-Rail Mount |
DPDT |
CE; CUL; EAC; UL |
Bulk |
4.449 in (113 mm) |
22.5 in (571.5 mm) |
4.449 x 0.886 x 3.543 in (113 x 22.5 x 90 mm) |
3.543 in (90 mm) |
70 °C (158 °F) |
-25 °C (-13 °F) |
Snap-on |
With Fuse |
400 V |
|||||||||||||||||||||||||||||||||||||||
Littelfuse |
Monitoring Relay |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
Littelfuse |
Monitoring Relay |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
Littelfuse |
Monitoring Relay |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Omron |
Monitoring Relay |
DIN-Rail Mount |
Momentary |
SPDT |
CCC; CE; UL |
5A@250VAC |
30 ms |
50000 Cycle(s) |
3.543 in (90 mm) |
17.5 in (444.5 mm) |
IP20 |
3.543 x 0.689 x 3.543 in (90 x 17.5 x 90 mm) |
3.543 in (90 mm) |
5A@30VDC |
60 °C (140 °F) |
5 A |
-20 °C (-4 °F) |
5 A |
Screw and Snap-on |
30 V |
250 V |
AC/DC |
|||||||||||||||||||||||||||||||
Omron |
Monitoring Relay |
DIN-Rail/Panel Mount |
Momentary |
SPDT |
AC |
CCC; CE; CSA; CUL; EN; KC; UL |
5A@250VAC |
24 V |
1 Form C |
240 V |
50000 Cycle(s) |
20 MΩ |
3.74 W |
3.74 in (95 mm) |
22.5 in (571.5 mm) |
IP20 |
3.74 x 0.886 x 3.937 in (95 x 22.5 x 100 mm) |
3.937 in (100 mm) |
5A@30VDC |
60 °C (140 °F) |
5 A |
-20 °C (-4 °F) |
5 A |
Screw and Snap-on |
480 V |
Random |
30 V |
250 V |
AC/DC |
|||||||||||||||||||||||||
Omron |
Monitoring Relay |
DIN-Rail/Panel Mount |
Momentary |
SPDT |
AC |
CCC; CE; CSA; CUL; EN; KC; UL |
5A@250VAC |
12 V |
1 Form C |
240 V |
50000 Cycle(s) |
20 MΩ |
3.74 W |
3.74 in (95 mm) |
22.5 in (571.5 mm) |
IP20 |
3.74 x 0.886 x 3.937 in (95 x 22.5 x 100 mm) |
3.937 in (100 mm) |
5A@30VDC |
60 °C (140 °F) |
5 A |
-20 °C (-4 °F) |
5 A |
Screw and Snap-on |
240 V |
Random |
30 V |
250 V |
AC/DC |
|||||||||||||||||||||||||
|
Omron |
Monitoring Relay |
DIN-Rail Mount |
SPDT |
CCC; CE; CSA; CUL; KC; UL |
5A@250VAC |
2 Form C |
50000 Cycle(s) |
20 MΩ |
3.74 in (95 mm) |
22.5 in (571.5 mm) |
IP20 |
12 |
3.74 x 0.886 x 3.937 in (95 x 22.5 x 100 mm) |
3.937 in (100 mm) |
5A@30VDC |
60 °C (140 °F) |
5 A |
-20 °C (-4 °F) |
5 A |
Screw |
30 V |
Contains 2 SPDT Output Relays |
250 V |
AC/DC |
Special function relays are a type of electrical switch that can perform a specific function based on their design and construction. They are designed for specific applications that require unique features such as high voltage or current capacity, high-speed switching, or low power consumption.
Some examples of special function relays include time delay relays, latching relays, safety relays, and solid-state relays. Time delay relays are used to control the timing of circuits or processes and can be programmed to switch on or off after a certain amount of time. Latching relays, on the other hand, require a pulse of current to switch on and remain on even after the pulse is removed until a reset pulse is applied.
Safety relays are designed to interrupt power to a machine or process when a safety interlock is activated, helping to prevent accidents or injuries. Solid-state relays use electronic components such as transistors and diodes to switch high loads and are preferred in applications that require high speed, low noise, and long life.