Part | RoHS | Manufacturer | Sensors or Transducers Type | Mounting Feature | No. of Terminals | Output Type | Package Shape or Style | Output Range | Package Body Material | Minimum Range Of Magnetic Field | Maximum Supply Voltage | Maximum Output Current | Technology | Screening Level | Input Mode | Maximum Magnetic Field Range | Hysteresis | Body Length/Diameter | Body Width | Power Supplies (V) | Output Circuit Type | Resistance | Package Equivalence Code | No. of Axes | Sub-Category | Linearity (%) | Body Height | Minimum Supply Voltage | Maximum Operating Temperature | Response Time | Minimum Operating Temperature | Sensitivity (mV/G) | Terminal Finish | Termination Type | Output Interface Type | Output (V) | Maximum Operating Current | Output Polarity | Additional Features | Maximum Measurement Range (mm) | Housing | JESD-609 Code | Operating Frequency | Minimum Measurement Range (mm) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
PLASTIC/EPOXY |
-7 mT |
BIPOLAR |
BIPOLAR(LATCHED) |
7 mT |
3.5/20 |
SIP3,.03,50 |
Other Sensors |
85 Cel |
-20 Cel |
MATTE TIN |
OPEN-COLLECTOR |
10 mA |
NON-INVERTING |
e3 |
|||||||||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
CURRENT OUTPUT |
RECTANGULAR |
30-55mA |
12.5 mT |
28 V |
55 A |
AEC-Q100 |
UNIPOLAR |
20 mT |
2.5 mT |
4.1 mm |
1.5 inch |
SIP3,.03,50 |
3 mm |
3 V |
150 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-DRAIN |
4 mA |
LOW SENSITIVITY: BOP AND BRP OF 175G AND 150G TYPICAL |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
RECTANGULAR |
PLASTIC/EPOXY |
-4 mT |
24 V |
CMOS |
BIPOLAR(LATCHED) |
4 mT |
4.5 mT |
4 mm |
1.52 inch |
12 |
SIP3,.03,50 |
Other Sensors/Transducers |
4.6 mm |
3.5 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-DRAIN |
5 mA |
NON-INVERTING |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
300-700mV |
PLASTIC/EPOXY |
1 mT |
20 V |
25 A |
BIPOLAR |
13 mT |
8 mT |
2.9 mm |
1.6 inch |
3.5/20 |
TO-236 |
Other Sensors |
1.2 mm |
3.5 V |
85 Cel |
-20 Cel |
Matte Tin (Sn) |
SOLDER |
OPEN-COLLECTOR |
10 mA |
INVERTING |
e3 |
|||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.30-0.40V |
PLASTIC/EPOXY |
-.5 mT |
20 V |
25 A |
BIPOLAR |
8 mT |
8 mT |
3 mm |
1.6 inch |
12 |
TO-236 |
Other Sensors |
1.15 mm |
3 V |
125 Cel |
-40 Cel |
SOLDER |
PASSIVE PULL-UP |
3.5 mA |
INVERTING |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
DIGITAL VOLTAGE |
RECTANGULAR |
PLASTIC/EPOXY |
1 mT |
20 V |
BIPOLAR |
13 mT |
3 mm |
1.6 inch |
3.5/20 |
TO-236 |
Other Sensors |
1.2 mm |
3.5 V |
85 Cel |
-20 Cel |
Matte Tin (Sn) |
SOLDER |
OPEN-COLLECTOR |
10 mA |
INVERTING |
e3 |
||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
400mV |
PLASTIC/EPOXY |
-6 mT |
20 V |
25 A |
BIPOLAR |
6 mT |
8 mT |
3 mm |
1.6 inch |
12 |
TO-236 |
Other Sensors |
1.206 mm |
3.5 V |
150 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-COLLECTOR |
6 mA |
INVERTING |
e3 |
|||||||||||||||
Diodes Incorporated |
SURFACE MOUNT |
3 |
VOLTAGE OUTPUT |
RECTANGULAR |
PLASTIC/EPOXY |
1 mT |
20 V |
BIPOLAR |
10 mT |
8 mT |
2.9 mm |
1.6 inch |
3.5/20 |
TO-236 |
Other Sensors |
1.2 mm |
3.5 V |
85 Cel |
-20 Cel |
Tin/Lead (Sn/Pb) |
SOLDER |
OPEN-COLLECTOR |
10 mA |
INVERTING |
REVERSE POLARITY PROTECTION |
e0 |
||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
DIGITAL VOLTAGE |
RECTANGULAR |
400mV |
PLASTIC/EPOXY |
-6 mT |
20 V |
6 mT |
6 mT |
4.1 mm |
2.23 inch |
2.2/20 |
SIP3,.03,50 |
Other Sensors/Transducers |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
PASSIVE PULL-UP |
4 mA |
e3 |
|||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.30-0.40V |
PLASTIC/EPOXY |
-3 mT |
20 V |
25 A |
3 mT |
6 mT |
2.9 mm |
1.6 inch |
2.2/20 |
TO-236 |
Other Sensors |
1.1 mm |
2.2 V |
125 Cel |
-40 Cel |
Matte Tin (Sn) |
SOLDER |
PASSIVE PULL-UP |
4 mA |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.30V |
PLASTIC/EPOXY |
1 mT |
5.5 V |
4 mT |
.8 mT |
2.01 mm |
1.51 inch |
3 |
SOLCC3/6,.09,20 |
Other Sensors |
.4 mm |
2.5 V |
85 Cel |
-40 Cel |
NICKEL PALLADIUM GOLD |
SOLDER |
OPEN-DRAIN |
10 mA |
NON-INVERTING |
BATTERY OPERATION |
e4 |
||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
VOLTAGE OUTPUT |
RECTANGULAR |
PLASTIC/EPOXY |
-6 mT |
20 V |
25 A |
6 mT |
6 mT |
4.1 mm |
1.5 inch |
12 |
SIP3,.02,50 |
Other Sensors |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-DRAIN |
4 mA |
e3 |
|||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.30-0.40V |
PLASTIC/EPOXY |
-3 mT |
20 V |
25 A |
3 mT |
6 mT |
4.1 mm |
1.52 inch |
2.2/20 |
SIP3,.03,50 |
Other Sensors |
3.03 mm |
2.2 V |
125 Cel |
-40 Cel |
Matte Tin (Sn) |
SOLDER |
PASSIVE PULL-UP |
4 mA |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.1-2.8V |
PLASTIC/EPOXY |
-4 mT |
5.5 V |
BIPOLAR |
4 mT |
1 mT |
3 mm |
1.6 inch |
2.5/5 |
TO-236 |
Other Sensors |
1.206 mm |
2.4 V |
85 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
9 mA |
NON-INVERTING |
BATTERY OPERATION |
e3 |
||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
400mV |
PLASTIC/EPOXY |
-6 mT |
20 V |
25 A |
6 mT |
6 mT |
3 mm |
1.6 inch |
2.2/20 |
TO-236 |
Other Sensors/Transducers |
1.206 mm |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
PASSIVE PULL-UP |
4 mA |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
PLASTIC/EPOXY |
AEC-Q100 |
3/28 |
OPEN-DRAIN |
TO-236 |
Other Sensors/Transducers |
150 Cel |
-40 Cel |
MATTE TIN |
4 mA |
e3 |
|||||||||||||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
SQUARE |
0.30V |
PLASTIC/EPOXY |
1 mT |
5.5 V |
6 mT |
1.5 mT |
2.01 mm |
2.01 inch |
3 |
SOLCC3/6,.09,20 |
Other Sensors |
.6 mm |
2.5 V |
85 Cel |
-40 Cel |
NICKEL PALLADIUM GOLD |
SOLDER |
OPEN-DRAIN |
9 mA |
NON-INVERTING |
BATTERY OPERATION |
e4 |
||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
700mV |
PLASTIC/EPOXY |
-6 mT |
20 V |
25 A |
6 mT |
6 mT |
3 mm |
1.6 inch |
12 |
TO-236 |
Other Sensors |
1.206 mm |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-DRAIN |
4 mA |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
PLASTIC/EPOXY |
AEC-Q100 |
3/28 |
OPEN-DRAIN |
SIP3,.03,50 |
Other Sensors/Transducers |
150 Cel |
-40 Cel |
MATTE TIN |
4 mA |
e3 |
|||||||||||||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
DIGITAL VOLTAGE |
RECTANGULAR |
PLASTIC/EPOXY |
-6 mT |
20 V |
BIPOLAR |
6 mT |
6 mT |
2.9 mm |
1.3 inch |
2.2/20 |
TO-236 |
Other Sensors/Transducers |
1.05 mm |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
PASSIVE PULL-UP |
4 mA |
NON-INVERTING |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.30V |
PLASTIC/EPOXY |
1 mT |
5.5 V |
1 A |
BIPOLAR |
6 mT |
1 mT |
3 mm |
1.6 inch |
3/5 |
TO-236 |
Other Sensors |
1.206 mm |
2.5 V |
85 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-DRAIN |
9 mA |
INVERTING |
BATTERY OPERATION |
e3 |
||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
400mV |
PLASTIC/EPOXY |
-6 mT |
20 V |
25 A |
6 mT |
6 mT |
3 mm |
1.6 inch |
2.2/20 |
TO-236 |
Other Sensors/Transducers |
1.206 mm |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
PASSIVE PULL-UP |
4 mA |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
PLASTIC/EPOXY |
AEC-Q100 |
3/28 |
OPEN-DRAIN |
TO-236 |
Other Sensors/Transducers |
150 Cel |
-40 Cel |
MATTE TIN |
4 mA |
e3 |
|||||||||||||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
CURRENT OUTPUT |
RECTANGULAR |
30-55mA |
PLASTIC/EPOXY |
-9 mT |
28 V |
55 A |
AEC-Q100 |
9 mT |
14 mT |
4.1 mm |
2.235 inch |
3/28 |
OPEN-DRAIN |
SIP3,.03 |
Other Sensors/Transducers |
3 V |
150 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
4 mA |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
CURRENT OUTPUT |
RECTANGULAR |
30-55mA |
PLASTIC |
-4 mT |
28 V |
55 A |
AEC-Q100 |
BIPOLAR |
4 mT |
5 mT |
2.9 mm |
1.3 inch |
TO-236 |
1.025 mm |
3 V |
150 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
4 mA |
e3 |
||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.10-0.30V |
PLASTIC/EPOXY |
1 mT |
5.5 V |
10 A |
6 mT |
1 mT |
3 mm |
1.6 inch |
3 |
TO-236 |
Other Sensors/Transducers |
1.15 mm |
2.5 V |
85 Cel |
-40 Cel |
Matte Tin (Sn) |
SOLDER |
OPEN-DRAIN |
.5 mA |
NON-INVERTING |
e3 |
||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
SQUARE |
0.20-1.60V |
PLASTIC/EPOXY |
.6 mT |
3.3 V |
5.5 mT |
.8 mT |
2 mm |
2 inch |
1.8/3 |
SOLCC3/6,.09,20 |
Other Sensors/Transducers |
.6 mm |
1.65 V |
85 Cel |
-40 Cel |
NICKEL PALLADIUM GOLD |
SOLDER |
OPEN-DRAIN |
4 mA |
COMPLEMENTARY |
BATTERY OPERATION, ITS ALSO USE MAGNETIC RANGE MINUS 0.6 TO MINUS 5.5 MT |
e4 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
400mV |
PLASTIC/EPOXY |
-6 mT |
20 V |
25 A |
6 mT |
6 mT |
4.1 mm |
1.5 inch |
2.2/20 |
SIP3,.03,50 |
Other Sensors/Transducers |
3 mm |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
PASSIVE PULL-UP |
4 mA |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
CURRENT OUTPUT |
RECTANGULAR |
50-90mA |
PLASTIC/EPOXY |
-6 mT |
28 V |
90 A |
6 mT |
6 mT |
4.1 mm |
1.5 inch |
SIP3,.03,50 |
4.55 mm |
3 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-DRAIN |
6 mA |
SEATED HEIGHT-CALCULATED |
e3 |
||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.10-0.30V |
PLASTIC/EPOXY |
1 mT |
5.5 V |
1 A |
6 mT |
1 mT |
3 mm |
1.6 inch |
3 |
TO-236 |
Other Sensors |
1.25 mm |
2.5 V |
85 Cel |
-40 Cel |
Matte Tin (Sn) |
SOLDER |
OPEN-DRAIN |
.01 mA |
NON-INVERTING |
2.5V TO 5.5V BATTERY OPERATION |
e3 |
|||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.30V |
PLASTIC/EPOXY |
1 mT |
5.5 V |
1 A |
6 mT |
1.5 mT |
4.1 mm |
1.5 inch |
3 |
SIP3,.03 |
Other Sensors |
3 mm |
2.5 V |
85 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-DRAIN |
9 mA |
NON-INVERTING |
BATTERY OPERATION |
e3 |
|||||||||||||||
Diodes Incorporated |
THROUGH HOLE MOUNT |
3 |
PLASTIC/EPOXY |
-6 mT |
6 mT |
2.2/20 |
SIP3,.03,50 |
Other Sensors |
125 Cel |
-40 Cel |
Tin/Lead (Sn/Pb) |
PASSIVE PULL-UP |
4 mA |
e0 |
||||||||||||||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.10-0.30V |
PLASTIC/EPOXY |
1 mT |
5.5 V |
1 A |
6 mT |
1 mT |
4.1 mm |
1.52 inch |
3 |
SIP3,.03,50 |
Other Sensors |
4.85 mm |
2.5 V |
85 Cel |
-40 Cel |
Matte Tin (Sn) |
SOLDER |
OPEN-DRAIN |
.5 mA |
NON-INVERTING |
2.5V TO 5.5V BATTERY OPERATION |
e3 |
|||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
VOLTAGE OUTPUT |
RECTANGULAR |
PLASTIC/EPOXY |
-6 mT |
20 V |
25 A |
6 mT |
6 mT |
4.1 mm |
1.5 inch |
12 |
SIP3,.02,50 |
Other Sensors |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-DRAIN |
4 mA |
e3 |
|||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.30V |
PLASTIC/EPOXY |
1 mT |
5.5 V |
1 A |
6 mT |
1.5 mT |
4.1 mm |
1.5 inch |
3 |
SIP3,.03,50 |
Other Sensors |
3 mm |
2.5 V |
85 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-DRAIN |
9 mA |
NON-INVERTING |
BATTERY OPERATION |
e3 |
|||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.2-1.6V |
PLASTIC/EPOXY |
3.5 mT |
3.3 V |
7.9 mT |
.8 mT |
1.6 mm |
1.175 inch |
1.8 |
SOLCC3/6,.09,20 |
Other Sensors |
.585 mm |
1.65 V |
85 Cel |
-40 Cel |
NICKEL PALLADIUM GOLD |
SOLDER |
4 mA |
INVERTING |
BATTERY OPERATION |
e4 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.10-0.30V |
PLASTIC/EPOXY |
1 mT |
5.5 V |
1 A |
6 mT |
1 mT |
3 mm |
1.6 inch |
3 |
TO-236 |
Other Sensors |
1.25 mm |
2.5 V |
85 Cel |
-40 Cel |
Matte Tin (Sn) |
SOLDER |
OPEN-DRAIN |
.5 mA |
NON-INVERTING |
2.5V TO 5.5V BATTERY OPERATION |
e3 |
|||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
SQUARE |
PLASTIC/EPOXY |
1 mT |
5.5 V |
4 mT |
.8 mT |
2 mm |
2 inch |
3 |
SOLCC3/6,.09,20 |
Other Sensors/Transducers |
.5 mm |
2.5 V |
85 Cel |
-40 Cel |
Nickel/Palladium/Gold (Ni/Pd/Au) |
SOLDER |
OPEN-DRAIN |
10 mA |
NON-INVERTING |
BATTERY OPERATION |
e4 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.10-0.30V |
PLASTIC/EPOXY |
1 mT |
5.5 V |
1 A |
6 mT |
1 mT |
4.1 mm |
1.52 inch |
3 |
SIP3,.03,50 |
Other Sensors |
4.85 mm |
2.5 V |
85 Cel |
-40 Cel |
Matte Tin (Sn) |
SOLDER |
OPEN-DRAIN |
.01 mA |
NON-INVERTING |
2.5V TO 5.5V BATTERY OPERATION |
e3 |
|||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
CURRENT OUTPUT |
RECTANGULAR |
30-55mA |
PLASTIC |
-4 mT |
28 V |
55 A |
AEC-Q100 |
BIPOLAR |
4 mT |
5 mT |
3 mm |
1.6 inch |
1.15 mm |
3 V |
150 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
4 mA |
e3 |
|||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
700mV |
PLASTIC/EPOXY |
-6 mT |
20 V |
25 A |
6 mT |
6 mT |
3 mm |
1.6 inch |
12 |
TO-236 |
Other Sensors |
1.206 mm |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-DRAIN |
4 mA |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
700mV |
PLASTIC/EPOXY |
-6 mT |
20 V |
25 A |
6 mT |
6 mT |
4.1 mm |
1.5 inch |
12 |
SIP3,.02,50 |
Other Sensors |
3 mm |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-DRAIN |
4 mA |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
700mV |
PLASTIC/EPOXY |
-6 mT |
20 V |
25 A |
6 mT |
6 mT |
4.1 mm |
1.5 inch |
12 |
SIP3,.02,50 |
Other Sensors |
3 mm |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
OPEN-DRAIN |
4 mA |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
CURRENT OUTPUT |
RECTANGULAR |
30-55mA |
PLASTIC |
-4 mT |
28 V |
55 A |
AEC-Q100 |
BIPOLAR |
4 mT |
5 mT |
4.1 mm |
1.5 inch |
SIP3 |
5.5 mm |
3 V |
150 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
4 mA |
e3 |
||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
SQUARE |
0.30V |
PLASTIC/EPOXY |
1 mT |
5.5 V |
BIPOLAR |
6 mT |
1 mT |
2.01 mm |
2.01 inch |
3/5 |
SOLCC3/6,.09,20 |
Other Sensors |
.6 mm |
2.5 V |
85 Cel |
-40 Cel |
NICKEL PALLADIUM GOLD |
SOLDER |
OPEN-DRAIN |
9 mA |
INVERTING |
BATTERY OPERATION |
e4 |
|||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
400mV |
PLASTIC/EPOXY |
-6 mT |
20 V |
25 A |
6 mT |
6 mT |
4.1 mm |
1.5 inch |
2.2/20 |
SIP3,.03,50 |
Other Sensors/Transducers |
3 mm |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
PASSIVE PULL-UP |
4 mA |
e3 |
|||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
DIGITAL VOLTAGE |
RECTANGULAR |
400mV |
PLASTIC/EPOXY |
-6 mT |
20 V |
6 mT |
6 mT |
4.1 mm |
1.5 inch |
2.2/20 |
SIP3,.03,50 |
Other Sensors/Transducers |
2.2 V |
125 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
PASSIVE PULL-UP |
4 mA |
e3 |
|||||||||||||||||||
|
Diodes Incorporated |
MAGNETIC FIELD SENSOR,HALL EFFECT |
SURFACE MOUNT |
3 |
ANALOG VOLTAGE |
RECTANGULAR |
0.2-1.6V |
PLASTIC/EPOXY |
3.5 mT |
3.3 V |
7.9 mT |
.8 mT |
1.6 mm |
1.175 inch |
1.8 |
SOLCC3/6,.09,20 |
Other Sensors |
.585 mm |
1.65 V |
85 Cel |
-40 Cel |
NICKEL PALLADIUM GOLD |
SOLDER |
4 mA |
NON-INVERTING |
BATTERY OPERATION |
e4 |
Magnetic field sensors are electronic devices that measure the strength and direction of magnetic fields and convert them into a measurable electrical signal. They are commonly used in a variety of applications, such as navigation, automotive, industrial, and medical.
Magnetic field sensors work by detecting the change in magnetic field strength or direction as a magnetic field interacts with a sensing element. The sensing element is typically a small piece of magnetic material, such as a magnetoresistive or Hall-effect sensor, which generates a measurable electrical signal proportional to the strength and direction of the magnetic field.
There are several types of magnetic field sensors, including Hall-effect sensors, magnetoresistive sensors, and fluxgate sensors. Hall-effect sensors work by measuring the change in voltage across a thin strip of semiconductor material as it is exposed to a magnetic field. Magnetoresistive sensors work by measuring the change in resistance of a thin film of magnetic material as it is exposed to a magnetic field. Fluxgate sensors work by using a coil to detect the magnetic field and a feedback circuit to measure the strength and direction of the field.