Part | RoHS | Manufacturer | Sensors or Transducers Type | Mounting Feature | No. of Terminals | Output Type | Package Shape or Style | Output Range | Package Body Material | Minimum Range Of Magnetic Field | Maximum Supply Voltage | Maximum Output Current | Technology | Screening Level | Input Mode | Maximum Magnetic Field Range | Hysteresis | Body Length/Diameter | Body Width | Power Supplies (V) | Output Circuit Type | Resistance | Package Equivalence Code | No. of Axes | Sub-Category | Linearity (%) | Body Height | Minimum Supply Voltage | Maximum Operating Temperature | Response Time | Minimum Operating Temperature | Sensitivity (mV/G) | Terminal Finish | Termination Type | Output Interface Type | Output (V) | Maximum Operating Current | Output Polarity | Additional Features | Maximum Measurement Range (mm) | Housing | JESD-609 Code | Operating Frequency | Minimum Measurement Range (mm) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Tt Electronics Plc |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG CURRENT |
RECTANGULAR |
25mA |
PLASTIC/EPOXY |
2.5 mT |
24 V |
25 A |
BIPOLAR |
UNIPOLAR |
26 mT |
2 mT |
4.57 mm |
4.55 inch |
4.5/24 |
820 ohm |
SIP3,.03,50 |
Other Sensors/Transducers |
4.57 mm |
4.5 V |
85 Cel |
-20 Cel |
SOLDER |
OPEN-COLLECTOR |
7 mA |
INVERTING |
PLASTIC |
||||||||||||||
|
Tt Electronics Plc |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG CURRENT |
RECTANGULAR |
25mA |
PLASTIC/EPOXY |
5 mT |
24 V |
25 A |
BIPOLAR |
UNIPOLAR |
35 mT |
5 mT |
4.57 mm |
4.55 inch |
4.5/24 |
820 ohm |
SIP3,.03,50 |
Other Sensors/Transducers |
4.57 mm |
4.5 V |
85 Cel |
-20 Cel |
SOLDER |
OPEN-COLLECTOR |
7 mA |
INVERTING |
PLASTIC |
||||||||||||||
|
Tt Electronics Plc |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG CURRENT |
RECTANGULAR |
25mA |
PLASTIC/EPOXY |
5 mT |
24 V |
25 A |
BIPOLAR |
UNIPOLAR |
22 mT |
3.5 mT |
4.57 mm |
4.55 inch |
4.5/24 |
820 ohm |
SIP3,.03,50 |
Other Sensors/Transducers |
4.57 mm |
4.5 V |
125 Cel |
-40 Cel |
SOLDER |
OPEN-COLLECTOR |
7 mA |
INVERTING |
PLASTIC |
||||||||||||||
|
Tt Electronics Plc |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG CURRENT |
RECTANGULAR |
25mA |
PLASTIC/EPOXY |
5 mT |
24 V |
25 A |
BIPOLAR |
UNIPOLAR |
35 mT |
5 mT |
4.57 mm |
4.55 inch |
4.5/24 |
820 ohm |
SIP3,.03,50 |
Other Sensors/Transducers |
4.57 mm |
4.5 V |
125 Cel |
-40 Cel |
SOLDER |
OPEN-COLLECTOR |
7 mA |
INVERTING |
PLASTIC |
||||||||||||||
|
Tt Electronics Plc |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG CURRENT |
RECTANGULAR |
25mA |
PLASTIC/EPOXY |
-15 mT |
24 V |
25 A |
BIPOLAR |
UNIPOLAR |
15 mT |
2 mT |
4.57 mm |
4.55 inch |
4.5/24 |
820 ohm |
SIP3,.03,50 |
Other Sensors/Transducers |
4.57 mm |
4.5 V |
125 Cel |
-40 Cel |
SOLDER |
OPEN-COLLECTOR |
7 mA |
INVERTING |
PLASTIC |
||||||||||||||
|
The Cherry |
MAGNETIC FIELD SENSOR,HALL EFFECT |
ANALOG VOLTAGE |
CYLINDRICAL |
25mA |
6 mT |
24 V |
25 A |
24.5 mT |
25.4 mm |
3.8 V |
150 Cel |
-40 Cel |
WIRE |
3-WIRE INTERFACE |
7.5 mA |
REVERSE BATTERY PROTECTION |
ALUMINIUM |
||||||||||||||||||||||||||
|
Tt Electronics Plc |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG CURRENT |
RECTANGULAR |
25mA |
PLASTIC/EPOXY |
-10 mT |
24 V |
25 A |
BIPOLAR |
BIPOLAR |
18 mT |
2.5 mT |
4.57 mm |
4.55 inch |
4.5/24 |
820 ohm |
SIP3,.03,50 |
Other Sensors/Transducers |
4.57 mm |
4.5 V |
150 Cel |
-40 Cel |
SOLDER |
OPEN-COLLECTOR |
9 mA |
INVERTING |
PLASTIC |
||||||||||||||
|
The Cherry |
MAGNETIC FIELD SENSOR,HALL EFFECT |
FLANGE MOUNT |
DIGITAL CURRENT |
CYLINDRICAL |
25mA |
24 V |
25 A |
18.92 mm |
57 mm |
5 V |
140 Cel |
-40 Cel |
6 mA |
||||||||||||||||||||||||||||||
|
Tt Electronics Plc |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG CURRENT |
RECTANGULAR |
25mA |
PLASTIC/EPOXY |
-13.5 mT |
24 V |
25 A |
BIPOLAR |
BIPOLAR |
13.5 mT |
1 mT |
4.57 mm |
4.55 inch |
4.5/24 |
820 ohm |
SIP3,.03,50 |
Other Sensors/Transducers |
4.57 mm |
4.5 V |
125 Cel |
-40 Cel |
SOLDER |
OPEN-COLLECTOR |
7 mA |
INVERTING |
PLASTIC |
||||||||||||||
|
Tt Electronics Plc |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG CURRENT |
RECTANGULAR |
25mA |
PLASTIC/EPOXY |
2.5 mT |
24 V |
25 A |
BIPOLAR |
UNIPOLAR |
27 mT |
2 mT |
4.57 mm |
4.55 inch |
4.5/24 |
820 ohm |
SIP3,.03,50 |
Other Sensors/Transducers |
4.57 mm |
4.5 V |
125 Cel |
-40 Cel |
SOLDER |
OPEN-COLLECTOR |
7 mA |
INVERTING |
PLASTIC |
Magnetic field sensors are electronic devices that measure the strength and direction of magnetic fields and convert them into a measurable electrical signal. They are commonly used in a variety of applications, such as navigation, automotive, industrial, and medical.
Magnetic field sensors work by detecting the change in magnetic field strength or direction as a magnetic field interacts with a sensing element. The sensing element is typically a small piece of magnetic material, such as a magnetoresistive or Hall-effect sensor, which generates a measurable electrical signal proportional to the strength and direction of the magnetic field.
There are several types of magnetic field sensors, including Hall-effect sensors, magnetoresistive sensors, and fluxgate sensors. Hall-effect sensors work by measuring the change in voltage across a thin strip of semiconductor material as it is exposed to a magnetic field. Magnetoresistive sensors work by measuring the change in resistance of a thin film of magnetic material as it is exposed to a magnetic field. Fluxgate sensors work by using a coil to detect the magnetic field and a feedback circuit to measure the strength and direction of the field.