Part | RoHS | Manufacturer | Sensors or Transducers Type | Mounting Feature | No. of Terminals | Output Type | Package Shape or Style | Output Range | Package Body Material | Minimum Range Of Magnetic Field | Maximum Supply Voltage | Maximum Output Current | Technology | Screening Level | Input Mode | Maximum Magnetic Field Range | Hysteresis | Body Length/Diameter | Body Width | Power Supplies (V) | Output Circuit Type | Resistance | Package Equivalence Code | No. of Axes | Sub-Category | Linearity (%) | Body Height | Minimum Supply Voltage | Maximum Operating Temperature | Response Time | Minimum Operating Temperature | Sensitivity (mV/G) | Terminal Finish | Termination Type | Output Interface Type | Output (V) | Maximum Operating Current | Output Polarity | Additional Features | Maximum Measurement Range (mm) | Housing | JESD-609 Code | Operating Frequency | Minimum Measurement Range (mm) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,MAGNETORESISTIVE |
DIGITAL VOLTAGE |
CYLINDRICAL |
350mV |
30 V |
10 V |
107 Cel |
-40 Cel |
CONNECTOR |
STAINLESS STEEL |
||||||||||||||||||||||||||||||||||
|
Allegro MicroSystems |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
4 |
DIGITAL CURRENT |
CYLINDRICAL |
PLASTIC/EPOXY |
3 mT |
24 V |
BICMOS |
100 mT |
4/24 |
SIP4,.18,50 |
Other Sensors/Transducers |
4 V |
150 Cel |
-40 Cel |
MATTE TIN |
SOLDER |
2-WIRE INTERFACE |
16.8 mA |
PLASTIC |
e3 |
|||||||||||||||||||||
|
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
3 |
ANALOG CURRENT |
CYLINDRICAL |
PLASTIC/EPOXY |
-42 mT |
10.5 V |
1.5 A |
42 mT |
4.064 mm |
1.57 inch |
5 |
SINGLE-ENDED |
SMSIP3H,.21,50 |
Other Sensors |
-1.5 |
2.99 mm |
4.5 V |
150 Cel |
-40 Cel |
5.4 mV/G |
SOLDER |
3-WIRE INTERFACE |
SINGLE-ENDED |
8.7 mA |
|||||||||||||||||
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,HALL EFFECT |
FLANGE MOUNT |
DIGITAL OUTPUT |
CYLINDRICAL |
18 V |
20 A |
15 mm |
45.5 mm |
4.5 V |
150 Cel |
-40 Cel |
WIRE |
4-WIRE INTERFACE |
OPEN-COLLECTOR |
18 mA |
SHORT CIRCUIT PROTECTION |
||||||||||||||||||||||||||||
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,HALL EFFECT |
FLANGE MOUNT |
DIGITAL OUTPUT |
CYLINDRICAL |
18 V |
20 A |
15 mm |
45.5 mm |
4.5 V |
150 Cel |
-40 Cel |
CONNECTOR |
4-WIRE INTERFACE |
OPEN-COLLECTOR |
18 mA |
SHORT CIRCUIT PROTECTION |
||||||||||||||||||||||||||||
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,HALL EFFECT |
FLANGE MOUNT |
DIGITAL OUTPUT |
CYLINDRICAL |
18 V |
20 A |
15 mm |
45.5 mm |
4.5 V |
150 Cel |
-40 Cel |
CONNECTOR |
4-WIRE INTERFACE |
OPEN-COLLECTOR |
18 mA |
SHORT CIRCUIT PROTECTION |
||||||||||||||||||||||||||||
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,HALL EFFECT |
FLANGE MOUNT |
DIGITAL OUTPUT |
CYLINDRICAL |
18 V |
20 A |
15 mm |
45.5 mm |
4.5 V |
150 Cel |
-40 Cel |
CONNECTOR |
4-WIRE INTERFACE |
OPEN-COLLECTOR |
18 mA |
SHORT CIRCUIT PROTECTION |
||||||||||||||||||||||||||||
|
The Cherry |
MAGNETIC FIELD SENSOR,HALL EFFECT |
ANALOG VOLTAGE |
CYLINDRICAL |
25mA |
6 mT |
24 V |
25 A |
24.5 mT |
25.4 mm |
3.8 V |
150 Cel |
-40 Cel |
WIRE |
3-WIRE INTERFACE |
7.5 mA |
REVERSE BATTERY PROTECTION |
ALUMINIUM |
||||||||||||||||||||||||||
|
Littelfuse |
MAGNETIC FIELD SENSOR,HALL EFFECT |
FLANGE MOUNT |
3 |
DIGITAL VOLTAGE |
CYLINDRICAL |
24 V |
20 A |
17.86 mm |
36.75 mm |
4.75 V |
125 Cel |
-40 Cel |
FLEXIBLE WIRE |
3-WIRE INTERFACE |
10.5 mA |
SHORT CIRCUIT AND REVERSE VOLTAGE PROTECTION |
|||||||||||||||||||||||||||
|
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,HALL EFFECT |
DIGITAL CURRENT |
CYLINDRICAL |
32 V |
4.5 V |
125 Cel |
-40 Cel |
Matte Tin (Sn) |
CONNECTOR |
40 mA |
IP67, IP68, IP69K, REVERSE POLARITY PROTECTION |
e3 |
|||||||||||||||||||||||||||||||
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,MAGNETORESISTIVE |
DIGITAL VOLTAGE |
CYLINDRICAL |
350mV |
30 V |
10 V |
107 Cel |
-40 Cel |
CONNECTOR |
STAINLESS STEEL |
||||||||||||||||||||||||||||||||||
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,MAGNETORESISTIVE |
DIGITAL VOLTAGE |
CYLINDRICAL |
350mV |
30 V |
10 V |
107 Cel |
-40 Cel |
CONNECTOR |
SHIELDED |
STAINLESS STEEL |
|||||||||||||||||||||||||||||||||
|
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,HALL EFFECT |
ANALOG VOLTAGE |
CYLINDRICAL |
14.50 |
12 mT |
24 V |
20 A |
49.5 mT |
4 mT |
25.4 mm |
6 V |
100 Cel |
-40 Cel |
WIRE |
10 mA |
||||||||||||||||||||||||||||
|
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,HALL EFFECT |
PANEL MOUNT |
ANALOG CURRENT |
CYLINDRICAL |
20mA |
-12 mT |
25 V |
20 A |
12 mT |
25.4 mm |
-.5 V |
100 Cel |
-40 Cel |
3-WIRE INTERFACE |
10 mA |
||||||||||||||||||||||||||||
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,MAGNETORESISTIVE |
DIGITAL VOLTAGE |
CYLINDRICAL |
350mV |
30 V |
10 V |
107 Cel |
-40 Cel |
CONNECTOR |
STAINLESS STEEL |
||||||||||||||||||||||||||||||||||
|
Honeywell Sensing And Control |
MAGNETIC FIELD SENSOR,HALL EFFECT |
ANALOG VOLTAGE |
CYLINDRICAL |
0.40V |
.5 mT |
24 V |
20 A |
2.5 mT |
.2 mT |
12.44 mm |
25.4 mm |
6 V |
85 Cel |
-40 Cel |
WIRE |
11 mA |
|||||||||||||||||||||||||||
|
The Cherry |
MAGNETIC FIELD SENSOR,HALL EFFECT |
FLANGE MOUNT |
DIGITAL CURRENT |
CYLINDRICAL |
25mA |
24 V |
25 A |
18.92 mm |
57 mm |
5 V |
140 Cel |
-40 Cel |
6 mA |
||||||||||||||||||||||||||||||
Texas Instruments |
MAGNETIC FIELD SENSOR,HALL EFFECT |
THROUGH HOLE MOUNT |
DIGITAL VOLTAGE |
CYLINDRICAL |
0-38V |
-4 mT |
38 V |
4 mT |
5 mT |
4.825 mm |
6.1 mm |
2.5 V |
125 Cel |
-40 Cel |
SOLDER |
3.5 mA |
SHORT CIRCUIT PROTECTION |
PLASTIC |
||||||||||||||||||||||||||
|
Littelfuse |
MAGNETIC FIELD SENSOR,HALL EFFECT |
FLANGE MOUNT |
3 |
DIGITAL VOLTAGE |
CYLINDRICAL |
24 V |
20 A |
17.86 mm |
36.75 mm |
4.75 V |
125 Cel |
-40 Cel |
FLEXIBLE WIRE |
3-WIRE INTERFACE |
10.5 mA |
SHORT CIRCUIT AND REVERSE VOLTAGE PROTECTION |
|||||||||||||||||||||||||||
|
Littelfuse |
MAGNETIC FIELD SENSOR,HALL EFFECT |
FLANGE MOUNT |
3 |
DIGITAL VOLTAGE |
CYLINDRICAL |
24 V |
20 A |
17.86 mm |
36.75 mm |
4.75 V |
125 Cel |
-40 Cel |
FLEXIBLE WIRE |
3-WIRE INTERFACE |
10.5 mA |
SHORT CIRCUIT AND REVERSE VOLTAGE PROTECTION |
Magnetic field sensors are electronic devices that measure the strength and direction of magnetic fields and convert them into a measurable electrical signal. They are commonly used in a variety of applications, such as navigation, automotive, industrial, and medical.
Magnetic field sensors work by detecting the change in magnetic field strength or direction as a magnetic field interacts with a sensing element. The sensing element is typically a small piece of magnetic material, such as a magnetoresistive or Hall-effect sensor, which generates a measurable electrical signal proportional to the strength and direction of the magnetic field.
There are several types of magnetic field sensors, including Hall-effect sensors, magnetoresistive sensors, and fluxgate sensors. Hall-effect sensors work by measuring the change in voltage across a thin strip of semiconductor material as it is exposed to a magnetic field. Magnetoresistive sensors work by measuring the change in resistance of a thin film of magnetic material as it is exposed to a magnetic field. Fluxgate sensors work by using a coil to detect the magnetic field and a feedback circuit to measure the strength and direction of the field.