0.4-2.9V Pressure Sensors 13

Reset All
Part RoHS Manufacturer Sensors or Transducers Type Mounting Feature Output Type Package Shape or Style Output Range Package Body Material Maximum Supply Voltage Pressure Sensing Mode Port Type No. of Bits Sensitivity (mV/V) Body Length/Diameter Body Width Maximum Accuracy (%) Linearity (%) Body Height Minimum Supply Voltage Maximum Operating Temperature Response Time Minimum Operating Temperature Terminal Finish Termination Type Output Interface Type Maximum Operating Current Additional Features Maximum Pressure Range Housing JESD-609 Code Minimum Pressure Range Nominal Offset

MPL115A1T1

NXP Semiconductors

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

DIGITAL VOLTAGE

RECTANGULAR

0.4-2.9V

5.5 V

ABSOLUTE

HOLE

16

5 mm

3 inch

1.2 mm

2.375 V

105 Cel

-40 Cel

NICKEL GOLD

SOLDER

SPI INTERFACE

.005 mA

ACCURACY IS PLUS OR MINUS 1 KPA

16.675 Psi

e4

7.25 Psi

KP256XTMA2

Infineon Technologies

PRESSURE SENSOR,CAPACITIVE

SURFACE MOUNT

DIGITAL VOLTAGE

SQUARE

0.4-2.9V

3.475 V

ABSOLUTE

HOLE

10

7 mm

7 inch

2.8 mm

3.135 V

125 Cel

-40 Cel

NICKEL PALLADIUM GOLD

SOLDER

SPI INTERFACE

10 mA

23.93 Psi

PLASTIC

e4

8.7 Psi

KP256XTMA1

Infineon Technologies

PRESSURE SENSOR,CAPACITIVE

SURFACE MOUNT

DIGITAL VOLTAGE

SQUARE

0.4-2.9V

3.475 V

ABSOLUTE

HOLE

10

7 mm

7 inch

2.8 mm

3.135 V

125 Cel

-40 Cel

Nickel/Palladium/Gold (Ni/Pd/Au)

SOLDER

SPI INTERFACE

10 mA

AEC-Q100; IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 V; IT HAS SENSITIVITY OF 9.74 LSB/KPA

23.931 Psi

PLASTIC

e4

8.702 Psi

MPL115A1ST1

NXP Semiconductors

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

DIGITAL VOLTAGE

RECTANGULAR

0.4-2.9V

5.5 V

ABSOLUTE

HOLE

16

5 mm

3 inch

1.2 mm

2.375 V

105 Cel

-40 Cel

SOLDER

SPI

.005 mA

16.6793 Psi

7.25189 Psi

MPL115A1

NXP Semiconductors

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

DIGITAL VOLTAGE

RECTANGULAR

0.4-2.9V

5.5 V

ABSOLUTE

HOLE

16

5 mm

3 inch

1.2 mm

2.375 V

105 Cel

-40 Cel

SOLDER

SPI INTERFACE

.005 mA

ACCURACY IS PLUS OR MINUS 1 KPA

16.675 Psi

7.25 Psi

MPL115A1T2

Freescale Semiconductor

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

DIGITAL VOLTAGE

RECTANGULAR

0.4-2.9V

5.5 V

ABSOLUTE

HOLE

16

5 mm

3 inch

1.2 mm

2.375 V

105 Cel

-40 Cel

SOLDER

SPI INTERFACE

.005 mA

ACCURACY IS PLUS OR MINUS 1 KPA

16.675 Psi

7.25 Psi

MPL115A1S

NXP Semiconductors

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

DIGITAL VOLTAGE

RECTANGULAR

0.4-2.9V

5.5 V

ABSOLUTE

HOLE

16

5 mm

3 inch

1.2 mm

2.375 V

105 Cel

-40 Cel

SOLDER

SPI

.005 mA

16.6793 Psi

7.25189 Psi

KP253

Infineon Technologies

PRESSURE SENSOR,CAPACITIVE

SURFACE MOUNT

DIGITAL VOLTAGE

SQUARE

0.4-2.9V

3.475 V

BAROMETRIC

HOLE

12

7 mm

7 inch

2.8 mm

3.135 V

125 Cel

-40 Cel

SOLDER

SPI INTERFACE

10 mA

IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 V

23.931 Psi

PLASTIC

8.702 Psi

KP256

Infineon Technologies

PRESSURE SENSOR,CAPACITIVE

SURFACE MOUNT

DIGITAL VOLTAGE

SQUARE

0.4-2.9V

3.475 V

ABSOLUTE

HOLE

10

7 mm

7 inch

2.8 mm

3.135 V

125 Cel

-40 Cel

SOLDER

SPI INTERFACE

10 mA

AEC-Q100; IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 V; IT HAS SENSITIVITY OF 9.74 LSB/KPA

23.931 Psi

PLASTIC

8.702 Psi

KP254

Infineon Technologies

PRESSURE SENSOR,CAPACITIVE

SURFACE MOUNT

DIGITAL VOLTAGE

SQUARE

0.4-2.9V

3.475 V

ABSOLUTE

HOLE

10

7 mm

7 inch

2.8 mm

3.135 V

125 Cel

-40 Cel

SOLDER

SPI INTERFACE

10 mA

AEC-Q100; IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 V; IT HAS SENSITIVITY OF 13.64 LSB/KPA

16.679 Psi

PLASTIC

5.801 Psi

KP253XTMA2

Infineon Technologies

PRESSURE SENSOR,CAPACITIVE

SURFACE MOUNT

DIGITAL VOLTAGE

SQUARE

0.4-2.9V

3.475 V

BAROMETRIC

HOLE

12

7 mm

7 inch

2.8 mm

3.135 V

125 Cel

-40 Cel

NICKEL PALLADIUM GOLD

SOLDER

SPI INTERFACE

10 mA

IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 V

23.931 Psi

PLASTIC

e4

8.702 Psi

KP254XTMA1

Infineon Technologies

PRESSURE SENSOR,CAPACITIVE

SURFACE MOUNT

DIGITAL VOLTAGE

SQUARE

0.4-2.9V

3.475 V

ABSOLUTE

HOLE

10

7 mm

7 inch

2.8 mm

3.135 V

125 Cel

-40 Cel

Nickel/Palladium/Gold (Ni/Pd/Au)

SOLDER

SPI INTERFACE

10 mA

AEC-Q100; IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 V; IT HAS SENSITIVITY OF 13.64 LSB/KPA

16.679 Psi

PLASTIC

e4

5.801 Psi

SP001399102

Infineon Technologies

PRESSURE SENSOR,CAPACITIVE

SURFACE MOUNT

DIGITAL VOLTAGE

SQUARE

0.4-2.9V

3.475 V

BAROMETRIC

HOLE

12

7 mm

7 inch

2.8 mm

3.135 V

125 Cel

-40 Cel

SOLDER

SPI INTERFACE

10 mA

IT ALSO HAS SUPPLY VOLTAGE 4.75 TO 5.25 V

23.931 Psi

PLASTIC

8.702 Psi

Pressure Sensors

Pressure sensors are electronic devices that are used to measure the pressure of gases or liquids in a variety of applications. They convert physical pressure into an electrical signal that can be measured, processed, and used for control or monitoring purposes.

Pressure sensors can be classified into two main categories: absolute pressure sensors and gauge pressure sensors. Absolute pressure sensors measure the pressure relative to a vacuum or absolute zero pressure, while gauge pressure sensors measure the pressure relative to atmospheric pressure.

Pressure sensors work based on the principle of converting pressure into an electrical signal. This can be achieved using different sensing technologies, including strain gauge, capacitive, piezoelectric, and optical sensing.

Strain gauge pressure sensors use a thin metal film that changes resistance as the pressure applied to it changes. Capacitive pressure sensors use the change in capacitance between two plates as the pressure changes. Piezoelectric pressure sensors use crystals that generate an electrical signal in response to pressure, and optical pressure sensors use the change in light transmission through a material as the pressure changes.

Pressure sensors are used in a wide range of applications, including automotive, aerospace, industrial, medical, and consumer electronics. In the automotive industry, they are used for monitoring tire pressure and engine oil pressure. In the aerospace industry, they are used for monitoring cabin pressure and fuel pressure. In the medical industry, they are used for monitoring blood pressure and respiratory pressure. In the industrial sector, they are used for process control and monitoring.