4.5V Pressure Sensors 15

Reset All
Part RoHS Manufacturer Sensors or Transducers Type Mounting Feature Output Type Package Shape or Style Output Range Package Body Material Maximum Supply Voltage Pressure Sensing Mode Port Type No. of Bits Sensitivity (mV/V) Body Length/Diameter Body Width Maximum Accuracy (%) Linearity (%) Body Height Minimum Supply Voltage Maximum Operating Temperature Response Time Minimum Operating Temperature Terminal Finish Termination Type Output Interface Type Maximum Operating Current Additional Features Maximum Pressure Range Housing JESD-609 Code Minimum Pressure Range Nominal Offset

40PC250G2A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

GAGE

STRAIGHT

13.21 mm

11.13 inch

0.2

0.1

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 16 MV/PSI SENSITIVITY

250 Psi

0 Psi

40PC015V2A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

VACUUM GAGE

STRAIGHT

13.21 mm

11.13 inch

0.4

0.3

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 266.6 MV/PSI SENSITIVITY

-15 Psi

0 Psi

40PC150G2A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

GAGE

STRAIGHT

13.21 mm

11.13 inch

0.2

0.1

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 26.6 MV/PSI SENSITIVITY

150 Psi

0 Psi

40PC100G2A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

GAGE

STRAIGHT

13.21 mm

11.13 inch

0.2

0.1

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 40 MV/PSI SENSITIVITY

100 Psi

0 Psi

40PC100G1A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

GAGE

STRAIGHT

13.21 mm

11.13 inch

0.2

0.1

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 40 MV/PSI SENSITIVITY

100 Psi

0 Psi

40PC015V1A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

VACUUM GAGE

STRAIGHT

13.21 mm

11.13 inch

0.4

0.3

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 266.6 MV/PSI SENSITIVITY

-15 Psi

0 Psi

40PC015G3A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

GAGE

STRAIGHT

13.21 mm

11.13 inch

0.4

0.2

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 266.6 MV/PSI SENSITIVITY

15 Psi

0 Psi

40PC150G3A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

GAGE

STRAIGHT

0.2

0.1

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 26.6 MV/PSI SENSITIVITY

150 Psi

0 Psi

40PC500G2A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

GAGE

STRAIGHT

13.21 mm

11.13 inch

0.2

0.2

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 8 MV/PSI SENSITIVITY

500 Psi

0 Psi

40PC100G3A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

GAGE

STRAIGHT

13.21 mm

11.13 inch

0.2

0.1

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 40 MV/PSI SENSITIVITY

100 Psi

0 Psi

40PC015V3A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

VACUUM GAGE

STRAIGHT

13.21 mm

11.13 inch

0.4

0.3

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 266.6 MV/PSI SENSITIVITY

-15 Psi

0 Psi

40PC006G2A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

GAGE

STRAIGHT

13.21 mm

11.13 inch

0.4

0.2

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 13.33 MV/PSI SENSITIVITY

5.801 Psi

0 Psi

40PC015G1A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

GAGE

STRAIGHT

13.21 mm

11.13 inch

0.4

0.2

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 266.6 MV/PSI SENSITIVITY

15 Psi

0 Psi

40PC250G3A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

GAGE

STRAIGHT

13.21 mm

11.13 inch

0.2

0.1

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 16 MV/PSI SENSITIVITY

250 Psi

0 Psi

40PC150G1A

Honeywell Sensing And Control

PRESSURE SENSOR,PIEZORESISTIVE

SURFACE MOUNT

ANALOG VOLTAGE

RECTANGULAR

4.5V

5.25 V

GAGE

STRAIGHT

13.21 mm

11.13 inch

0.2

0.1

9.65 mm

4.75 V

125 Cel

-45 Cel

TERMINALS

10 mA

ITS ALSO OPERTARES IN 26.6 MV/PSI SENSITIVITY

150 Psi

0 Psi

Pressure Sensors

Pressure sensors are electronic devices that are used to measure the pressure of gases or liquids in a variety of applications. They convert physical pressure into an electrical signal that can be measured, processed, and used for control or monitoring purposes.

Pressure sensors can be classified into two main categories: absolute pressure sensors and gauge pressure sensors. Absolute pressure sensors measure the pressure relative to a vacuum or absolute zero pressure, while gauge pressure sensors measure the pressure relative to atmospheric pressure.

Pressure sensors work based on the principle of converting pressure into an electrical signal. This can be achieved using different sensing technologies, including strain gauge, capacitive, piezoelectric, and optical sensing.

Strain gauge pressure sensors use a thin metal film that changes resistance as the pressure applied to it changes. Capacitive pressure sensors use the change in capacitance between two plates as the pressure changes. Piezoelectric pressure sensors use crystals that generate an electrical signal in response to pressure, and optical pressure sensors use the change in light transmission through a material as the pressure changes.

Pressure sensors are used in a wide range of applications, including automotive, aerospace, industrial, medical, and consumer electronics. In the automotive industry, they are used for monitoring tire pressure and engine oil pressure. In the aerospace industry, they are used for monitoring cabin pressure and fuel pressure. In the medical industry, they are used for monitoring blood pressure and respiratory pressure. In the industrial sector, they are used for process control and monitoring.