Part | RoHS | Manufacturer | Thermal Device Type | Body Material | Construction | Airflow | Noise | Approvals (V) | Minimum Operating Temperature | Life Expectancy | Height | Width | Diameter | Speed | Bearing Type | Additional Features | Packing Method | Pressure | Weight | Voltage (Rated) | Length | Power (Rated) | Current (Rated) | Maximum Operating Temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Knight Electronics |
DC Fan |
PBT |
7 cfm (11.893 m³/h) |
25 dB |
CUL; TUV |
-20 °C (-4 °F) |
60,000 h |
1.575 in (40 mm) |
0.413 in (10.5 mm) |
6000 rpm |
Ball |
Approvals: UL |
2.54 mmH₂O (24.909 pa) |
18 g |
12 V |
1.575 in (40 mm) |
100 mA |
75 °C (167 °F) |
|||||
|
Knight Electronics |
DC Fan |
PBT |
50 cfm (84.951 m³/h) |
42 dB |
CUL; UL |
-20 °C (-4 °F) |
70,000 h |
3.169 in (80.5 mm) |
1.26 in (32 mm) |
2.776 in (70.5 mm) |
3800 rpm |
Ball |
7.365 mmH₂O (72.226 pa) |
24 V |
3.169 in (80.5 mm) |
120 mA |
70 °C (158 °F) |
||||||
|
Knight Electronics |
AC Fan |
PBT |
110 cfm (186.891 m³/h) |
37 dB |
CUL; UL |
-20 °C (-4 °F) |
60,000 h |
4.705 in (119.5 mm) |
1.496 in (38 mm) |
3000 rpm |
Ball |
7.11 mmH₂O (69.725 pa) |
115 V |
4.705 in (119.5 mm) |
15 W |
80 °C (176 °F) |
|||||||
|
Knight Electronics |
AC Fan |
PBT |
300 cfm (509.703 m³/h) |
61 dB |
CUL; TUV |
-40 °C (-40 °F) |
60,000 h |
5.906 in (150 mm) |
2.008 in (51 mm) |
3300 rpm |
Ball |
Approvals: UL |
19.81 mmH₂O (194.27 pa) |
120 V |
6.772 in (172 mm) |
50 W |
70 °C (158 °F) |
||||||
|
Ebm-papst Mulfingen & Kg |
DC Fan |
PBT |
Tubeaxial |
112 cfm (190.289 m³/h) |
66 dB |
-20 °C (-4 °F) |
3.15 in (80 mm) |
1.496 in (38 mm) |
Ball |
199.58 g |
24 V |
3.15 in (80 mm) |
25 W |
70 °C (158 °F) |
|||||||||
|
Mechatronics |
DC Fan |
PBT |
Axial |
46 cfm (78.154 m³/h) |
35 dB |
UL |
3.15 in (80 mm) |
0.984 in (25 mm) |
3600 rpm |
Ball |
5.25 mmH₂O (51.485 pa) |
82 g |
12 V |
3.15 in (80 mm) |
240 mA |
||||||||
|
Cui |
DC Fan |
PBT |
Axial |
13.8 cfm (23.446 m³/h) |
30.7 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
1.969 in (50 mm) |
0.394 in (10 mm) |
5800 rpm |
Approvals: TUV; UL |
3.81 mmH₂O (37.363 pa) |
19.5 g |
5 V |
1.969 in (50 mm) |
900 mW |
179 mA |
70 °C (158 °F) |
||||
|
Cui |
DC Fan |
PBT |
Axial |
41 cfm (69.659 m³/h) |
33 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
3.15 in (80 mm) |
0.984 in (25 mm) |
3200 rpm |
Approvals: TUV; UL |
4.57 mmH₂O (44.816 pa) |
75 g |
24 V |
3.15 in (80 mm) |
1.8 W |
75 mA |
70 °C (158 °F) |
||||
|
Cui |
DC Fan |
PBT |
Axial |
5.5 cfm (9.345 m³/h) |
12.3 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
0.787 in (20 mm) |
1.575 in (40 mm) |
4500 rpm |
Approvals: TUV; UL |
2.54 mmH₂O (24.909 pa) |
29 g |
12 V |
1.575 in (40 mm) |
460 mW |
38 mA |
70 °C (158 °F) |
||||
|
Cui |
DC Fan |
PBT |
Axial |
5.5 cfm (9.345 m³/h) |
12.3 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
0.787 in (20 mm) |
1.575 in (40 mm) |
4500 rpm |
Approvals: TUV; UL |
2.54 mmH₂O (24.909 pa) |
29 g |
12 V |
1.575 in (40 mm) |
460 mW |
38 mA |
70 °C (158 °F) |
||||
|
Cui |
DC Fan |
PBT |
Axial |
5.5 cfm (9.345 m³/h) |
12.3 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
0.787 in (20 mm) |
1.575 in (40 mm) |
4500 rpm |
Approvals: TUV; UL |
2.54 mmH₂O (24.909 pa) |
29 g |
12 V |
1.575 in (40 mm) |
460 mW |
38 mA |
70 °C (158 °F) |
||||
|
Cui |
DC Fan |
PBT |
Axial |
93 cfm (158.008 m³/h) |
37 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
4.724 in (120 mm) |
1.496 in (38 mm) |
2100 rpm |
Approvals: TUV; UL |
4.57 mmH₂O (44.816 pa) |
218 g |
12 V |
4.724 in (120 mm) |
3.33 W |
277 mA |
70 °C (158 °F) |
||||
|
Cui |
DC Fan |
PBT |
Axial |
93 cfm (158.008 m³/h) |
37 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
4.724 in (120 mm) |
1.496 in (38 mm) |
2100 rpm |
Approvals: TUV; UL |
4.57 mmH₂O (44.816 pa) |
218 g |
12 V |
4.724 in (120 mm) |
3.33 W |
277 mA |
70 °C (158 °F) |
||||
|
Knight Electronics |
DC Fan |
PBT |
26 cfm (44.174 m³/h) |
23 dB |
CUL; UL |
-10 °C (14 °F) |
65,000 h |
3.15 in (80 mm) |
0.984 in (25 mm) |
2.815 in (71.5 mm) |
2100 rpm |
Ball |
1.777 mmH₂O (17.426 pa) |
12 V |
3.15 in (80 mm) |
80 mA |
70 °C (158 °F) |
||||||
|
Cui |
DC Fan |
PBT |
Axial |
93 cfm (158.008 m³/h) |
40.5 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
4.724 in (120 mm) |
0.984 in (25 mm) |
2700 rpm |
Approvals: TUV; UL |
5.59 mmH₂O (54.819 pa) |
162 g |
12 V |
4.724 in (120 mm) |
3.46 W |
288 mA |
70 °C (158 °F) |
||||
|
Cui |
DC Fan |
PBT |
Axial |
93 cfm (158.008 m³/h) |
40.5 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
4.724 in (120 mm) |
0.984 in (25 mm) |
2700 rpm |
Approvals: TUV; UL |
5.59 mmH₂O (54.819 pa) |
162 g |
12 V |
4.724 in (120 mm) |
3.46 W |
288 mA |
70 °C (158 °F) |
||||
|
Cui |
DC Fan |
PBT |
Axial |
93 cfm (158.008 m³/h) |
37 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
4.724 in (120 mm) |
1.496 in (38 mm) |
2100 rpm |
Approvals: TUV; UL |
4.57 mmH₂O (44.816 pa) |
218 g |
12 V |
4.724 in (120 mm) |
3.33 W |
277 mA |
70 °C (158 °F) |
||||
|
Cui |
DC Fan |
PBT |
Axial |
93 cfm (158.008 m³/h) |
40.5 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
4.724 in (120 mm) |
0.984 in (25 mm) |
2700 rpm |
Approvals: TUV; UL |
5.59 mmH₂O (54.819 pa) |
162 g |
12 V |
4.724 in (120 mm) |
3.46 W |
288 mA |
70 °C (158 °F) |
||||
|
Knight Electronics |
DC Fan |
PBT |
18 cfm (30.582 m³/h) |
27 dB |
TUV; UL |
-10 °C (14 °F) |
60,000 h |
2.362 in (60 mm) |
0.984 in (25 mm) |
3500 rpm |
Ball |
2.79 mmH₂O (27.361 pa) |
68 g |
12 V |
2.362 in (60 mm) |
1.7 W |
140 mA |
70 °C (158 °F) |
|||||
|
Cui |
DC Fan |
PBT |
Axial |
26.4 cfm (44.854 m³/h) |
34.2 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
0.591 in (15 mm) |
2.362 in (60 mm) |
4700 rpm |
Approvals: TUV; UL |
4.572 mmH₂O (44.836 pa) |
35.5 g |
12 V |
2.362 in (60 mm) |
1.77 W |
147 mA |
70 °C (158 °F) |
||||
|
Mechatronics |
DC Fan |
PBT |
Axial |
11 cfm (18.689 m³/h) |
29 dB |
CUL; TUV |
-10 °C (14 °F) |
60,000 h |
1.575 in (40 mm) |
0.787 in (20 mm) |
7000 rpm |
Ball |
Approvals: UL |
4.98 mmH₂O (48.837 pa) |
28 g |
24 V |
1.575 in (40 mm) |
80 mA |
70 °C (158 °F) |
||||
|
Knight Electronics |
AC Fan |
PBT |
300 cfm (509.703 m³/h) |
61 dB |
CUL; TUV |
-40 °C (-40 °F) |
60,000 h |
5.906 in (150 mm) |
2.008 in (51 mm) |
3300 rpm |
Ball |
Approvals: UL |
19.81 mmH₂O (194.27 pa) |
230 V |
6.772 in (172 mm) |
50 W |
70 °C (158 °F) |
||||||
|
Knight Electronics |
DC Fan |
PBT |
140 cfm (237.862 m³/h) |
46 dB |
CUL; UL |
-20 °C (-4 °F) |
60,000 h |
5 in (127 mm) |
1.516 in (38.5 mm) |
3000 rpm |
Ball |
10.413 mmH₂O (102.117 pa) |
24 V |
5 in (127 mm) |
230 mA |
75 °C (167 °F) |
|||||||
|
Knight Electronics |
DC Fan |
PBT |
850 cfm (1444.159 m³/h) |
64 dB |
CUL; TUV |
-20 °C (-4 °F) |
40,000 h |
3.504 in (89 mm) |
10 in (254 mm) |
2500 rpm |
Ball |
Approvals: UL |
21.082 mmH₂O (206.744 pa) |
1.81437 kg |
24 V |
64 W |
2.65 A |
75 °C (167 °F) |
|||||
Ebm-papst Mulfingen & Kg |
DC Fan |
PBT |
Axial |
47.09 cfm (80.006 m³/h) |
37 dB |
CSA; UL |
-20 °C (-4 °F) |
30,000 h |
3.622 in (92 mm) |
1.26 in (32 mm) |
3000 rpm |
Ball |
Approvals: VDE |
190 g |
48 V |
3.622 in (92 mm) |
2.4 W |
75 °C (167 °F) |
||||||
|
Knight Electronics |
AC Fan |
PBT |
600 cfm (1019.406 m³/h) |
55 dB |
CUL; TUV |
-20 °C (-4 °F) |
60,000 h |
3.504 in (89 mm) |
10 in (254 mm) |
2000 rpm |
Ball |
Approvals: UL |
11.43 mmH₂O (112.09 pa) |
2.4494 kg |
115 V |
45 W |
80 °C (176 °F) |
||||||
|
Knight Electronics |
AC Fan |
PBT |
850 cfm (1444.159 m³/h) |
69 dB |
CUL; TUV |
-20 °C (-4 °F) |
60,000 h |
3.504 in (89 mm) |
10 in (254 mm) |
2700 rpm |
Ball |
Approvals: UL |
19.812 mmH₂O (194.289 pa) |
2.4494 kg |
115 V |
75 W |
80 °C (176 °F) |
Industrial fans and blowers are mechanical devices that are used to move air or gas in industrial and commercial settings. They are commonly used for ventilation, cooling, drying, and conveying in applications such as manufacturing, mining, and HVAC systems.
Industrial fans and blowers come in a variety of types, including axial fans, centrifugal fans, and radial fans. Axial fans are the most common type and are used for applications that require a large volume of air to be moved at low pressure. Centrifugal fans are used for applications that require higher pressures, such as in HVAC systems. Radial fans are used for applications that require high flow rates and high pressures, such as in mining operations.
Industrial fans and blowers are powered by electric motors, diesel engines, or steam turbines. They can also be fitted with variable speed drives to control the airflow and pressure output.
Industrial fans and blowers offer several advantages over other types of air handling equipment. They are highly efficient and can move large volumes of air or gas over long distances. They are also highly reliable and can operate continuously for extended periods of time.
However, industrial fans and blowers also have some limitations, such as high noise levels and susceptibility to damage from external factors such as dirt, dust, and debris.