Part | RoHS | Manufacturer | Thermal Device Type | Body Material | Construction | Airflow | Noise | Approvals (V) | Minimum Operating Temperature | Life Expectancy | Height | Width | Diameter | Speed | Bearing Type | Additional Features | Packing Method | Pressure | Weight | Voltage (Rated) | Length | Power (Rated) | Current (Rated) | Maximum Operating Temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Delta Electronics |
DC Fan |
Plastic |
3.49 cfm (5.93 m³/h) |
35.5 dB |
CE; CUL; UL |
1.772 in (45 mm) |
0.394 in (10 mm) |
5900 rpm |
Ball |
Approvals: VDE |
14.22 mmH₂O (139.451 pa) |
18.1 g |
12 V |
1.772 in (45 mm) |
1.56 W |
130 mA |
||||||||
|
CUI Devices |
DC Fan |
Polybutylene Terephthalate |
Axial |
11.88 cfm (20.184 m³/h) |
34.2 dB |
CE; CUL; TUV |
-10 °C (14 °F) |
40,000 h |
1.575 in (40 mm) |
0.787 in (20 mm) |
9500 rpm |
Approvals: UL |
10.414 mmH₂O (102.126 pa) |
26.9 g |
5 V |
1.575 in (40 mm) |
2.35 W |
470 mA |
70 °C (158 °F) |
||||
|
Sunon |
DC Fan |
PBT/Polyethylene |
Axial |
108.2 cfm (183.833 m³/h) |
44.5 dB |
CE; CUL |
-10 °C (14 °F) |
70,000 h |
4.724 in (120 mm) |
0.984 in (25 mm) |
3100 rpm |
Ball |
Approvals: TUV; UL |
Box |
7.11 mmH₂O (69.725 pa) |
157 g |
12 V |
4.724 in (120 mm) |
5.4 W |
451 mA |
70 °C (158 °F) |
||
Sunon |
DC Fan |
Axial |
138 cfm (234.463 m³/h) |
48 dB |
0 °C (32 °F) |
4.724 in (120 mm) |
1.496 in (38 mm) |
3100 rpm |
Sleeve |
9.14 mmH₂O (89.633 pa) |
214 g |
12 V |
4.724 in (120 mm) |
9.6 W |
800 mA |
0 °C (32 °F) |
||||||||
Delta Electronics |
DC Fan |
Plastic |
Tubeaxial |
251.79 cfm (427.794 m³/h) |
58 dB |
CE; CSA; UL |
-10 °C (14 °F) |
80,000 h |
2 in (50.8 mm) |
5.906 in (150 mm) |
3350 rpm |
Ball |
Approvals: VDE |
17.49 mmH₂O (171.518 pa) |
840 g |
48 V |
6.772 in (172 mm) |
25.44 W |
530 mA |
70 °C (158 °F) |
||||
Delta Electronics |
DC Fan |
Axial |
80.16 cfm (136.193 m³/h) |
52.5 dB |
UL; CSA |
3.15 in (80 mm) |
1.496 in (38 mm) |
5700 rpm |
Ball |
20.63 mmH₂O (202.311 pa) |
170 g |
24 V |
3.15 in (80 mm) |
|||||||||||
Knight Electronics |
DC Fan |
|||||||||||||||||||||||
Knight Electronics |
DC Fan |
|||||||||||||||||||||||
Knight Electronics |
DC Fan |
|||||||||||||||||||||||
Knight Electronics |
DC Fan |
|||||||||||||||||||||||
Knight Electronics |
DC Fan |
|||||||||||||||||||||||
Knight Electronics |
DC Fan |
|||||||||||||||||||||||
Knight Electronics |
DC Fan |
Polybutylene Terephthalate |
Axial |
40 cfm (67.96 m³/h) |
33 dB |
CE; CUL; UL |
-15 °C (5 °F) |
60,000 h |
0.984 in (25 mm) |
3.15 in (80 mm) |
3300 rpm |
Ball |
Approvals: TUV; UKCA |
5.84 mmH₂O (57.271 pa) |
86.18 g |
12 V |
3.15 in (80 mm) |
2.2 W |
180 mA |
65 °C (149 °F) |
||||
Knight Electronics |
DC Fan |
Polybutylene Terephthalate |
Axial |
40 cfm (67.96 m³/h) |
33 dB |
CE; CUL; UL |
-20 °C (-4 °F) |
60,000 h |
0.984 in (25 mm) |
3.15 in (80 mm) |
3300 rpm |
Ball |
Approvals: TUV; UKCA |
5.84 mmH₂O (57.271 pa) |
86.18 g |
12 V |
3.15 in (80 mm) |
2.2 W |
180 mA |
65 °C (149 °F) |
||||
|
Knight Electronics |
DC Fan |
||||||||||||||||||||||
|
Ebm-papst Mulfingen & Kg |
DC Fan |
Glass Filled Plastic PA66 |
Centrifugal |
CSA; UL |
-25 °C (-13 °F) |
3.622 in (92 mm) |
9.921 in (252 mm) |
3150 rpm |
Ball |
1.4 kg |
24 V |
106 W |
5 A |
60 °C (140 °F) |
|||||||||
|
Ebm-papst Mulfingen & Kg |
DC Fan |
12.9 cfm (21.917 m³/h) |
-20 °C (-4 °F) |
70,000 h |
2.992 in (76 mm) |
1.063 in (27 mm) |
3500 rpm |
Ball |
75 g |
24 V |
2.992 in (76 mm) |
2.9 W |
70 °C (158 °F) |
||||||||||
Ebm-papst Mulfingen & Kg |
DC Fan |
Glass Filled Plastic |
Centrifugal |
37.66 cfm (63.985 m³/h) |
CE; CSA |
-20 °C (-4 °F) |
30,000 h |
0.984 in (25 mm) |
5 in (127 mm) |
5100 rpm |
Ball |
Approvals: UL; VDE |
320 g |
24 V |
5 in (127 mm) |
8 W |
340 mA |
75 °C (167 °F) |
||||||
|
Nmb Technologies |
DC Fan |
Axial |
8.1 cfm (13.762 m³/h) |
34 dB |
UL |
-10 °C (14 °F) |
1.575 in (40 mm) |
0.591 in (15 mm) |
8000 rpm |
Ball |
6.35 mmH₂O (62.272 pa) |
24 V |
1.575 in (40 mm) |
1.48 W |
62 A |
70 °C (158 °F) |
|||||||
|
Nmb Technologies |
DC Fan |
||||||||||||||||||||||
Ebm-papst Mulfingen & Kg |
DC Fan |
Glass Filled Polyamide |
Axial |
100.1 cfm (170.071 m³/h) |
45 dB |
UL |
-20 °C (-4 °F) |
4.685 in (119 mm) |
1.26 in (32 mm) |
2800 rpm |
Ball |
IP68 |
260 g |
12 V |
4.685 in (119 mm) |
5 W |
65 °C (149 °F) |
|||||||
Ebm-papst Mulfingen & Kg |
DC Fan |
Glass Filled PA |
Axial |
68.86 cfm (116.994 m³/h) |
50 dB |
-20 °C (-4 °F) |
30,000 h |
1 in (25.4 mm) |
3.15 in (80 mm) |
6200 rpm |
Ball |
105 g |
12 V |
3.15 in (80 mm) |
6.8 W |
70 °C (158 °F) |
||||||||
|
Sanyo Denki America |
DC Fan |
Plastic |
51.5 cfm (87.499 m³/h) |
37 dB |
CUL; TUV; UL |
-20 °C (-4 °F) |
40,000 h |
3.15 in (80 mm) |
0.992 in (25.2 mm) |
5200 rpm |
8.89 mmH₂O (87.181 pa) |
110 g |
24 V |
3.15 in (80 mm) |
2.4 W |
100 mA |
70 °C (158 °F) |
||||||
Knight Electronics |
DC Fan |
Industrial fans and blowers are mechanical devices that are used to move air or gas in industrial and commercial settings. They are commonly used for ventilation, cooling, drying, and conveying in applications such as manufacturing, mining, and HVAC systems.
Industrial fans and blowers come in a variety of types, including axial fans, centrifugal fans, and radial fans. Axial fans are the most common type and are used for applications that require a large volume of air to be moved at low pressure. Centrifugal fans are used for applications that require higher pressures, such as in HVAC systems. Radial fans are used for applications that require high flow rates and high pressures, such as in mining operations.
Industrial fans and blowers are powered by electric motors, diesel engines, or steam turbines. They can also be fitted with variable speed drives to control the airflow and pressure output.
Industrial fans and blowers offer several advantages over other types of air handling equipment. They are highly efficient and can move large volumes of air or gas over long distances. They are also highly reliable and can operate continuously for extended periods of time.
However, industrial fans and blowers also have some limitations, such as high noise levels and susceptibility to damage from external factors such as dirt, dust, and debris.