UL Current Sense Transformers 6

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Type (Primary) Window Dimension No. of Winding (Primary) Isolation Voltage Inductance (Primary) Packing Method Output Current-1 Minimum ET Product Output Current-2 Maximum DC Unbalance Current No. of Winding (Secondary) Sub-Category Dimensions Primary Current (Peak) Maximum Operating Temperature Application Inductance (Secondary) Output Voltage-2 Output Voltage-1 Minimum Operating Temperature Nominal Operating Frequency Height Width Diameter Nominal Input Voltage (V) Load Resistance Additional Features JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency Maximum Input Voltage (V)

CSE187L

Triad Magnetics

CURRENT SENSE TRANSFORMER

THROUGH HOLE MOUNTED

UL

WOUND PRIMARY

1

2500 V

30 A

.1 A

30000 mA

1

Other Transformers

L21.84XB0.0XH18.03 (mm)

30 A

95 Cel

SIGNAL

4 V

-30 Cel

18.03 mm

18.29 mm

60 ohm

WIDTH DIMENSION INCLUDES TERMINAL ALSO

.05 KHz

21.84 mm

1:500

.4 KHz

240

CSE187L-P

Triad Magnetics

CURRENT SENSE TRANSFORMER

THROUGH HOLE MOUNTED

UL

WOUND PRIMARY

1

4000 V

30 A

.1 A

1

Other Transformers

L22.22XB22.22XH18.29 (mm)

30 A

105 Cel

SIGNAL

.11 V

4 V

-40 Cel

18.29 mm

22.22 mm

21 ohm

.05 KHz

22.22 mm

1:500

.4 KHz

240

CST206-2A

Triad Magnetics

CURRENT SENSE TRANSFORMER

THROUGH HOLE MOUNTED

UL

BAR PRIMARY

56000 uH

4000 V-us

80000 mA

Other Transformers

L27.3XB10.16XH31.12 (mm)

80 A

POWER

56000 uH

31.12 mm

10.16 mm

200 ohm

20 KHz

27.3 mm

1:200

200 KHz

CS4050V-01L

Coilcraft

CURRENT SENSE TRANSFORMER

THROUGH HOLE MOUNTED

UL

Tin/Silver (Sn/Ag)

WOUND PRIMARY

TUBE

149 V-us

L19.56XB14.48XH19.05 (mm)

35 A

85 Cel

5000 uH

-40 Cel

19.05 mm

14.48 mm

.7 ohm

e2

3 KHz

19.56 mm

1:50

1000 KHz

CS4200V-01L

Coilcraft

CURRENT SENSE TRANSFORMER

THROUGH HOLE MOUNTED

UL

Tin/Silver (Sn/Ag)

WOUND PRIMARY

TUBE

596 V-us

L19.56XB14.48XH19.05 (mm)

35 A

85 Cel

80000 uH

-40 Cel

19.05 mm

14.48 mm

4 ohm

e2

1 KHz

19.56 mm

1:200

1000 KHz

CS4100V-01L

Coilcraft

CURRENT SENSE TRANSFORMER

THROUGH HOLE MOUNTED

UL

Tin/Silver (Sn/Ag)

WOUND PRIMARY

TUBE

298 V-us

L19.56XB14.48XH19.05 (mm)

35 A

85 Cel

20000 uH

-40 Cel

19.05 mm

14.48 mm

1.4 ohm

e2

2 KHz

19.56 mm

1:100

1000 KHz

Current Sense Transformers

Current Sense Transformers (CSTs) are essential components used in various electrical applications to measure and monitor electric current levels. They detect the magnetic field produced by the current passing through a wire, allowing for accurate and reliable measurements.

CSTs are made up of a magnetic core with a coil of wire wound around it. As current flows through the wire passing through the magnetic core, it produces a magnetic field that is detected by the coil. The output signal from the coil is proportional to the current flowing through the wire, allowing the current level to be measured.

CSTs provide high accuracy current measurements, enabling precise monitoring and control of electric current levels. They can operate over a wide frequency range, making them suitable for use in a variety of electrical applications. Additionally, they are easy to install and can be easily integrated into existing electrical systems. They are also available in various sizes, allowing them to be used in applications with limited space.

CSTs are used in various electrical applications, including motor control, power supplies, and inverters. They are also used in electrical safety systems to detect overcurrent conditions and trigger safety mechanisms.