Littelfuse Current Transformers 12

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Type (Primary) Window Dimension Isolation Voltage Packing Method Accuracy Class Current Rating Ip:Is (A) Dimensions Maximum Operating Temperature Minimum Operating Temperature Nominal Operating Frequency Height Width Diameter Nominal Input Voltage (V) Maximum Secondary Burden Minimum Operating Frequency Length Maximum Operating Frequency

CT200

Littelfuse

CURRENT SENSE TRANSFORMER

CHASSIS MOUNT

CSA

BAR PRIMARY

D57 m

2

50/60 HZ

108 mm

44.5 mm

98.3 mm

SE-CS10-4

Littelfuse

CURRENT TRANSFORMER

CHASSIS MOUNT

CSA; UL

BAR PRIMARY

D108 m

0.02

12.5:0.0625

50/400 HZ

169.9 mm

32.5 mm

169.9 mm

SE-CS30-4

Littelfuse

CURRENT TRANSFORMER

CHASSIS MOUNT

CSA; UL

BAR PRIMARY

D95 m

0.01

30:0.05

50/400 HZ

175 mm

33.5 mm

158 mm

SE-CS10-6

Littelfuse

CURRENT TRANSFORMER

CHASSIS MOUNT

CSA; UL

BAR PRIMARY

D160.3 m

0.02

12.5:0.0625

50/400 HZ

215.9 mm

31.8 mm

215.9 mm

SE-CS10-2.5

Littelfuse

CURRENT TRANSFORMER

CHASSIS MOUNT

CSA; UL

BAR PRIMARY

D63.5 m

0.02

12.5:0.0625

50/400 HZ

124 mm

27.9 mm

124 mm

SE-CS30-26

Littelfuse

CURRENT TRANSFORMER

CHASSIS MOUNT

CSA; UL

BAR PRIMARY

D26 m

0.01

30:0.05

50/400 HZ

72 mm

26.5 mm

68 mm

CT200L

Littelfuse

CURRENT SENSE TRANSFORMER

CHASSIS MOUNT

CSA

BAR PRIMARY

D89 m

2

50/60 HZ

144.5 mm

44.5 mm

139.7 mm

SE-CS30-8

Littelfuse

CURRENT TRANSFORMER

CHASSIS MOUNT

CSA; UL

BAR PRIMARY

D200 m

0.01

30:0.05

50/400 HZ

309 mm

33.5 mm

290 mm

SE-CS40-6

Littelfuse

CURRENT TRANSFORMER

CHASSIS MOUNT

CSA; UL

BAR PRIMARY

D160.3m

0.02

50:0.0625

50/400 HZ

215.9 mm

31.8 mm

215.9 mm

SE-CS30-70

Littelfuse

CURRENT TRANSFORMER

CHASSIS MOUNT

CSA; UL

BAR PRIMARY

D70 m

0.01

30:0.05

50/400 HZ

138 mm

30 mm

121 mm

SE-CS30-5

Littelfuse

CURRENT TRANSFORMER

CHASSIS MOUNT

CSA; UL

BAR PRIMARY

D130 m

0.01

30:0.05

50/400 HZ

218 mm

33.5 mm

203 mm

SE-CS10-8

Littelfuse

CURRENT TRANSFORMER

CHASSIS MOUNT

CSA; UL

BAR PRIMARY

D209.5 m

0.02

12.5:0.0625

50/400 HZ

266.7 mm

38.9 mm

266.7 mm

Current Transformers

Current Transformers (CTs) are electrical devices that are used to measure electrical current in power transmission systems. They are also known as instrument transformers, because they transform the high currents found in power lines into lower currents that can be safely measured by instruments.

The basic principle of a CT is to use the magnetic field generated by the current flowing through a conductor to induce a current in a secondary winding, which is connected to a measuring instrument or a protective relay. The current in the secondary winding is proportional to the primary current, and is typically a lower value, such as 1A or 5A, which is easier to measure.

CTs are typically used in high voltage and high power systems, such as power plants, substations, and industrial facilities, to measure the current flowing through transmission lines, generators, motors, and other equipment. They are also used for protection purposes, such as detecting overcurrents and faults in the system, and triggering circuit breakers to isolate faulty equipment.

CTs come in various shapes and sizes, and are designed for specific current ratings and frequency ranges. They are typically installed around the conductor that carries the current, and connected to the measuring or protective device through insulated leads. Proper installation and maintenance of CTs are critical to ensure accurate and reliable measurements and protection of the system.