CE, CUL, UL Power & Mains Transformers 11

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Power Rating Center Tap Feature-2 No. of Functions No. of Winding (Primary) Isolation Voltage Inductance (Primary) Packing Method Output Current-1 Minimum ET Product Output Current-2 No. of Winding (Secondary) Sub-Category Dimensions Volt-Ampere Rating (VA) Maximum Operating Temperature Center Tap Feature-1 Application Output Voltage-2 Output Voltage-1 Minimum Operating Temperature Nominal Operating Frequency Rating (Primary) Height Width Diameter Nominal Input Voltage (V) Load Resistance Additional Features Minimum Input Voltage (V) JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency Maximum Input Voltage (V)

VPM48-20830

Triad Magnetics

TOROIDAL POWER TRANSFORMER

STUD MOUNT

CE, CUL, UL

NO

4000 V

41.66 A

2

1000 VA

NO

24 V

24 V

50/60 HZ

DUAL 100/120/220/240V

183 mm

100/120/220/240

74 mm

VPT30-3330

Triad Magnetics

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL, UL

TIN

NO

2

4000 V

6.66 A

6.66 A

2

D87.0XH47.0 (mm)

100 VA

NO

POWER

15 V

15 V

50/60 HZ

DUAL 115V

51 mm

88 mm

115/230

e3

VPT30-5330

Triad Magnetics

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL, UL

TIN

NO

2

4000 V

8.88 A

8.88 A

2

D103.0XH48.0 (mm)

160 VA

NO

POWER

18 V

18 V

50/60 HZ

DUAL 115V

52 mm

106 mm

115/230

e3

VPM100-10000

Triad Magnetics

TOROIDAL POWER TRANSFORMER

STUD MOUNT

CE, CUL, UL

NO

4000 V

20 A

2

1000 VA

NO

50 V

50 V

50/60 HZ

DUAL 100/120/220/240V

183 mm

100/120/220/240

74 mm

VPM240-4170

Triad Magnetics

TOROIDAL POWER TRANSFORMER

STUD MOUNT

CE, CUL, UL

NO

4000 V

8.34 A

2

1000 VA

NO

120 V

120 V

50/60 HZ

DUAL 100/120/220/240V

183 mm

100/120/220/240

74 mm

VPT30-830

Triad Magnetics

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL, UL

TIN

NO

2

4000 V

1.66 A

1.66 A

2

D71.0XH32.0 (mm)

25 VA

NO

POWER

15 V

15 V

50/60 HZ

DUAL 115V

34 mm

74 mm

115/230

e3

VPM240-10400

Triad Magnetics

TOROIDAL POWER TRANSFORMER

STUD MOUNT

CE, CUL, UL

NO

4000 V

21.8 A

2

2500 VA

NO

120 V

120 V

50/60 HZ

DUAL 100/120/220/240V

215 mm

100/120/220/240

120 mm

VPM100-25000

Triad Magnetics

TOROIDAL POWER TRANSFORMER

STUD MOUNT

CE, CUL, UL

NO

4000 V

50 A

2

2500 VA

NO

50 V

50 V

50/60 HZ

DUAL 100/120/220/240V

215 mm

100/120/220/240

120 mm

VPT100-10000

Triad Magnetics

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL, UL

TIN

NO

2

4000 V

20 A

20 A

2

D175.0XH68.0 (mm)

1000 VA

NO

POWER

50 V

50 V

50/60 HZ

DUAL 115V

76 mm

178 mm

115/230

e3

VPT30-1670

Triad Magnetics

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL, UL

TIN

NO

2

4000 V

3.34 A

3.34 A

2

D80.0XH33.0 (mm)

50 VA

NO

POWER

15 V

15 V

50/60 HZ

DUAL 115V

36 mm

83 mm

115/230

e3

VPT100-25000

Triad Magnetics

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL, UL

TIN

NO

2

4000 V

50 A

50 A

2

D208.0XH112.0 (mm)

2500 VA

NO

POWER

50 V

50 V

50/60 HZ

DUAL 115V

120 mm

210 mm

115/230

e3

Power & Mains Transformers

Power and mains transformers are types of electrical transformers used in power transmission and distribution systems to convert high voltage and low current to low voltage and high current or vice versa. They are essential components in the electricity grid, and are used to step up or step down voltage levels for efficient transmission and distribution of electrical energy.

Power transformers are used in high voltage transmission systems, typically at voltages of 110 kV and above, to step up or step down the voltage levels. They have a high power rating, typically ranging from several hundred kVA to several thousand MVA, and are designed to handle high currents and voltages without overheating or breaking down. Power transformers are typically oil-immersed, and use a magnetic core made of laminated steel to reduce losses and improve efficiency.

Mains transformers, also known as distribution transformers, are used in low voltage distribution systems, typically at voltages of 11 kV or below, to step down the voltage levels for use by consumers. They have a lower power rating than power transformers, typically ranging from several kVA to several hundred kVA, and are designed to operate at lower voltages and currents. Mains transformers are typically dry-type, and use a magnetic core made of laminated steel or ferrite to reduce losses and improve efficiency.

Both power and mains transformers require proper design, selection, and maintenance to ensure reliable and efficient operation. They are subject to various standards and regulations, such as IEC (International Electrotechnical Commission) and IEEE (Institute of Electrical and Electronics Engineers), to ensure their safety and performance. Proper installation and maintenance of transformers, such as regular inspection, testing, and oil analysis, are also critical to ensure their longevity and performance.