UL Power & Mains Transformers 31

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Power Rating Center Tap Feature-2 No. of Functions No. of Winding (Primary) Isolation Voltage Inductance (Primary) Packing Method Output Current-1 Minimum ET Product Output Current-2 No. of Winding (Secondary) Sub-Category Dimensions Volt-Ampere Rating (VA) Maximum Operating Temperature Center Tap Feature-1 Application Output Voltage-2 Output Voltage-1 Minimum Operating Temperature Nominal Operating Frequency Rating (Primary) Height Width Diameter Nominal Input Voltage (V) Load Resistance Additional Features Minimum Input Voltage (V) JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency Maximum Input Voltage (V)

F-261U

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

8 A

1

Other Transformers

L87.3XB88.9XH104.77 (mm)

192 VA

YES

POWER

24 V

50/60 HZ

SINGLE 115V

104.77 mm

88.9 mm

87.3 mm

115

F-16X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

2500 V

3 A

1

Other Transformers

L84.12XB50.8XH49.2 (mm)

18.9 VA

YES

POWER

6.3 V

50/60 HZ

SINGLE 115V

49.2 mm

50.8 mm

84.12 mm

115

F-44X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

1.5 A

1

Other Transformers

L101.6XB57.15XH65.86 (mm)

25.2 VA

YES

POWER

35 V

50/60 HZ

SINGLE 115V

65.86 mm

57.15 mm

101.6 mm

115

F-118X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

.7 A

1

Other Transformers

L82.55XB50.8XH50.8 (mm)

16.8 VA

YES

POWER

24 V

50/60 HZ

SINGLE 115V

50.8 mm

50.8 mm

82.55 mm

115

F-341X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

2

1500 V

2 A

1

Other Transformers

L101.6XB57.15XH65.86 (mm)

50.4 VA

YES

POWER

25.2 V

50/60 HZ

SINGLE 115/230V

65.86 mm

57.15 mm

101.6 mm

FP24-500

Triad Magnetics

SPLIT BOBBIN POWER TRANSFORMER

THROUGH HOLE MOUNTED

UL

NO

2

2000 V

1 A

1 A

2

L63.5XB50.8XH26.97 (mm)

12 VA

NO

POWER

12 V

12 V

50/60 HZ

DUAL 115/230V

26.97 mm

50.8 mm

115/230

PCB MOUNTABLE

63.5 mm

F-219X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

4 A

1

Other Transformers

L101.6XB57.15XH65.07 (mm)

NO

POWER

12 V

60 HZ

SINGLE 115V

65.07 mm

57.15 mm

101.6 mm

115

F-45X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

1.7 A

1

Other Transformers

L101.6XB57.15XH65.86 (mm)

24 VA

YES

POWER

26.8 V

50/60 HZ

SINGLE 115V

65.86 mm

57.15 mm

101.6 mm

115

F-22A

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

2000 V

20 A

1

Other Transformers

L83.34XB104.77XH98.42 (mm)

126 VA

YES

POWER

6.3 V

50/60 HZ

SINGLE 115V

98.42 mm

104.77 mm

83.34 mm

115

F-193U

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

4 A

1

Other Transformers

L79.38XB71.42XH71.42 (mm)

96 VA

YES

POWER

24 V

50/60 HZ

SINGLE 115V

71.42 mm

71.42 mm

79.38 mm

115

FD7-36

Triad Magnetics

SPLIT BOBBIN POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

2

2500 V

1.5 A

1

Other Transformers

L68.25XB46.02XH57.15 (mm)

56 VA

YES

POWER

36 V

50/60 HZ

DUAL 115V

57.15 mm

46.02 mm

68.25 mm

F-345X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

2

1500 V

1 A

1

Other Transformers

L84.12XB50.8XH49.2 (mm)

24 VA

YES

POWER

24 V

50/60 HZ

SINGLE 115/230V

49.2 mm

50.8 mm

84.12 mm

F-40X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

1.5 A

1

Other Transformers

L101.6XB57.15XH65.86 (mm)

26.8 VA

YES

POWER

35 V

50/60 HZ

SINGLE 115V

65.86 mm

57.15 mm

101.6 mm

115

TCT40-01E07K

Triad Magnetics

SPLIT BOBBIN POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

1.67 A

1

Other Transformers

D92.5XH56.5 (mm)

40 VA

NO

POWER

24 V

50/60 HZ

SINGLE 120V

56.5 mm

59.44 mm

92.5 mm

92.46 mm

120

45063

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

UL

NO

4000 V

1.25 A

1.25 A

2

30 VA

50 Cel

NO

12 V

12 V

DUAL 115V

35 mm

57 mm

115

PARALLEL CONNECTED

68 mm

45045

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

UL

NO

4000 V

.583 A

.583 A

2

14 VA

50 Cel

NO

12 V

12 V

DUAL 115V

24 mm

57 mm

115

PARALLEL CONNECTED

68 mm

F-14X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

7.56 W

NO

1

2500 V

1.2 A

1

Other Transformers

L71.42XB41.27XH41.27 (mm)

YES

POWER

6.3 V

60 HZ

SINGLE 115V

41.27 mm

41.27 mm

71.42 mm

115

45062

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

UL

NO

4000 V

1.667 A

1.667 A

2

30 VA

50 Cel

NO

9 V

9 V

DUAL 115V

35 mm

57 mm

115

PARALLEL CONNECTED

68 mm

45065

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

45000

UL

NO

833 A

833 A

2

L68.0XB57.0XH35.0 (mm)

30 VA

NO

18 V

18 V

SINGLE 115/230V

35 mm

57 mm

68 mm

F-13X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

.6 A

1

Other Transformers

L60.32XB34.92XH34.92 (mm)

3.78 VA

NO

POWER

6.3 V

50/60 HZ

SINGLE 115V

34.92 mm

34.92 mm

60.32 mm

115

45059

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

UL

NO

4000 V

.667 A

.667 A

2

24 VA

50 Cel

NO

18 V

18 V

DUAL 115V

31 mm

57 mm

115

PARALLEL CONNECTED

68 mm

F-46X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

2.8 A

1

Other Transformers

L101.6XB57.15XH67.46 (mm)

24 VA

YES

POWER

25.2 V

50/60 HZ

SINGLE 115V

67.46 mm

57.15 mm

101.6 mm

115

F-25X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

2000 V

3 A

1

Other Transformers

L95.25XB53.97XH54.76 (mm)

18.9 VA

YES

POWER

10 V

50/60 HZ

SINGLE 115V

54.76 mm

53.97 mm

95.25 mm

115

F-216X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

2500 V

3 A

1

Other Transformers

L84.12XB50.8XH49.2 (mm)

4.2 VA

YES

POWER

6.3 V

50/60 HZ

SINGLE 115/230V

49.2 mm

50.8 mm

84.12 mm

115

45039

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

UL

NO

4000 V

.416 A

.416 A

2

10 VA

50 Cel

NO

12 V

12 V

DUAL 115V

22 mm

57 mm

115

PARALLEL CONNECTED

68 mm

45064

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

UL

NO

4000 V

1 A

1 A

2

30 VA

50 Cel

NO

15 V

15 V

DUAL 115V

35 mm

57 mm

115

PARALLEL CONNECTED

68 mm

F-70X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

1 A

1

Other Transformers

L84.12XB44.45XH49.2 (mm)

12.6 VA

YES

POWER

12.6 V

50/60 HZ

SINGLE 115V

49.2 mm

44.45 mm

84.12 mm

115

45042

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

UL

NO

4000 V

.208 A

.208 A

2

10 VA

50 Cel

NO

24 V

24 V

DUAL 115V

22 mm

57 mm

115

PARALLEL CONNECTED

68 mm

F-187U

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

4 A

1

Other Transformers

L73.02XB77.77XH88.9 (mm)

112 VA

YES

POWER

28 V

50/60 HZ

SINGLE 115V

88.9 mm

77.77 mm

73.02 mm

115

45052

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

UL

NO

4000 V

.6 A

.6 A

2

18 VA

50 Cel

NO

15 V

15 V

DUAL 115V

27 mm

57 mm

115

PARALLEL CONNECTED

68 mm

C4062

Avel Lindberg

POWER TRANSFORMER

UL

6.63 A

1

530 VA

60 HZ

Power & Mains Transformers

Power and mains transformers are types of electrical transformers used in power transmission and distribution systems to convert high voltage and low current to low voltage and high current or vice versa. They are essential components in the electricity grid, and are used to step up or step down voltage levels for efficient transmission and distribution of electrical energy.

Power transformers are used in high voltage transmission systems, typically at voltages of 110 kV and above, to step up or step down the voltage levels. They have a high power rating, typically ranging from several hundred kVA to several thousand MVA, and are designed to handle high currents and voltages without overheating or breaking down. Power transformers are typically oil-immersed, and use a magnetic core made of laminated steel to reduce losses and improve efficiency.

Mains transformers, also known as distribution transformers, are used in low voltage distribution systems, typically at voltages of 11 kV or below, to step down the voltage levels for use by consumers. They have a lower power rating than power transformers, typically ranging from several kVA to several hundred kVA, and are designed to operate at lower voltages and currents. Mains transformers are typically dry-type, and use a magnetic core made of laminated steel or ferrite to reduce losses and improve efficiency.

Both power and mains transformers require proper design, selection, and maintenance to ensure reliable and efficient operation. They are subject to various standards and regulations, such as IEC (International Electrotechnical Commission) and IEEE (Institute of Electrical and Electronics Engineers), to ensure their safety and performance. Proper installation and maintenance of transformers, such as regular inspection, testing, and oil analysis, are also critical to ensure their longevity and performance.