CHASSIS MOUNT Power & Mains Transformers 170

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Power Rating Center Tap Feature-2 No. of Functions No. of Winding (Primary) Isolation Voltage Inductance (Primary) Packing Method Output Current-1 Minimum ET Product Output Current-2 No. of Winding (Secondary) Sub-Category Dimensions Volt-Ampere Rating (VA) Maximum Operating Temperature Center Tap Feature-1 Application Output Voltage-2 Output Voltage-1 Minimum Operating Temperature Nominal Operating Frequency Rating (Primary) Height Width Diameter Nominal Input Voltage (V) Load Resistance Additional Features Minimum Input Voltage (V) JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency Maximum Input Voltage (V)

10-6

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

6 A

6 A

2

L85.7XB69.9XH71.4 (mm)

YES

5 V

5 V

50/60 HZ

SINGLE 115V

71.4 mm

69.9 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

85.7 mm

F-261U

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

8 A

1

Other Transformers

L87.3XB88.9XH104.77 (mm)

192 VA

YES

POWER

24 V

50/60 HZ

SINGLE 115V

104.77 mm

88.9 mm

87.3 mm

115

F-16X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

2500 V

3 A

1

Other Transformers

L84.12XB50.8XH49.2 (mm)

18.9 VA

YES

POWER

6.3 V

50/60 HZ

SINGLE 115V

49.2 mm

50.8 mm

84.12 mm

115

F-44X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

1.5 A

1

Other Transformers

L101.6XB57.15XH65.86 (mm)

25.2 VA

YES

POWER

35 V

50/60 HZ

SINGLE 115V

65.86 mm

57.15 mm

101.6 mm

115

F-118X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

.7 A

1

Other Transformers

L82.55XB50.8XH50.8 (mm)

16.8 VA

YES

POWER

24 V

50/60 HZ

SINGLE 115V

50.8 mm

50.8 mm

82.55 mm

115

68-4

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

68

YES

1500 V

4 A

4 A

2

114.3mm X 114.3mm X 95.3mm

YES

34 V

34 V

50/60 HZ

SINGLE 115V

95.3 mm

114.3 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

114.3 mm

10-25

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

50 A

25 A

2

L114.3XB95.3XH95.3 (mm)

YES

5 V

5 V

50/60 HZ

SINGLE 115V

95.3 mm

95.3 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

114.3 mm

F-341X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

2

1500 V

2 A

1

Other Transformers

L101.6XB57.15XH65.86 (mm)

50.4 VA

YES

POWER

25.2 V

50/60 HZ

SINGLE 115/230V

65.86 mm

57.15 mm

101.6 mm

732

Hammond Manufacturing

POWER TRANSFORMER

CHASSIS MOUNT

CSA

NO

1

500 VA

YES

2500 V

50/60 HZ

SINGLE 115V

115

115

739

Hammond Manufacturing

POWER TRANSFORMER

CHASSIS MOUNT

CSA

NO

1

1610 VA

YES

3500 V

50/60 HZ

SINGLE 115V

115

115

10-12

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

12 A

12 A

2

L95.3XB82.6XH79.4 (mm)

YES

5 V

5 V

50/60 HZ

SINGLE 115V

79.4 mm

82.6 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

95.3 mm

16-12

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

16

YES

1500 V

12 A

12 A

2

104.8mm X 98.4mm X 87.3mm

YES

8 V

8 V

50/60 HZ

SINGLE 115V

87.3 mm

98.4 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

104.8 mm

SIM800

Block Transformatoren-elektronik

POWER TRANSFORMER

CHASSIS MOUNT

CUL; EAC; UL; VDE

NO

2

800 VA

40 Cel

NO

12 V

12 V

50-60 HZ

SINGLE 230V

166.116 mm

199.898 mm

230

282.956 mm

36-1

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

36

YES

1500 V

1 A

1 A

2

76.2mm X 69.9mm X 63.5mm

YES

18 V

18 V

50/60 HZ

SINGLE 115V

63.5 mm

69.9 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

76.2 mm

36-2

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

2 A

2 A

2

85.7mm X 74.6mm X 71.4mm

YES

18 V

18 V

50/60 HZ

SINGLE 115V

71.4 mm

74.5 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

85.7 mm

56-25

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

56

YES

1500 V

25 A

25 A

2

162mm X 181mm X 134.9mm

YES

28 V

28 V

50/60 HZ

SINGLE 105/115/125V

134.9 mm

181 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

162 mm

36-4

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

36

YES

1500 V

4 A

4 A

2

104.8mm X 85.7mm X 87.3mm

YES

18 V

18 V

50/60 HZ

SINGLE 115V

87.3 mm

85.7 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

104.8 mm

F-219X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

4 A

1

Other Transformers

L101.6XB57.15XH65.07 (mm)

NO

POWER

12 V

60 HZ

SINGLE 115V

65.07 mm

57.15 mm

101.6 mm

115

56-12

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

12 A

12 A

2

L162XB133.4XH134.9 (mm)

YES

28 V

28 V

50/60 HZ

SINGLE 105/115/125V

134.9 mm

133.4 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

162 mm

10-8

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

8 A

8 A

2

L85.7XB79.4XH71.4 (mm)

YES

5 V

5 V

50/60 HZ

SINGLE 115V

71.4 mm

79.4 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

85.7 mm

10-4

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

4 A

4 A

2

L90.5XB60.3XH77.7 (mm)

YES

5 V

5 V

50/60 HZ

SINGLE 115V

77.7 mm

60.3 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

90.5 mm

263CX

Hammond Manufacturing

POWER TRANSFORMER

CHASSIS MOUNT

CSA

YES

2000 V

3 A

.287 A

2

116 VA

YES

5 V

360 V

60 HZ

SINGLE 115V

77.724 mm

63.5 mm

115

95.25 mm

16-25

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

16

YES

1500 V

25 A

25 A

2

114.3mm X 136.5mm X 95.3mm

YES

8 V

8 V

50/60 HZ

SINGLE 115V

95.3 mm

136.5 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

114.3 mm

24-50

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

50 A

50 A

2

L162XB158.8XH134.9 (mm)

YES

12 V

12 V

50/60 HZ

SINGLE 105/115/125V

134.9 mm

158.8 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

162 mm

F-45X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

1.7 A

1

Other Transformers

L101.6XB57.15XH65.86 (mm)

24 VA

YES

POWER

26.8 V

50/60 HZ

SINGLE 115V

65.86 mm

57.15 mm

101.6 mm

115

4782-01

Api Technologies

POWER TRANSFORMER

CHASSIS MOUNT

4782

NO

10 A

1

L76.2XB69.85XH66.04 (mm)

450 VA

NO

5 V

60 HZ

SINGLE 115V

66.04 mm

69.85 mm

76.2 mm

PH100MLI

Hammond Power Solutions

POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL

NO

.87 A

4.17 A

2

100 VA

NO

25 V

120 V

60 HZ

DUAL 240/480V

3.63 mm

3.25 mm

480/240

4.69 mm

PH50MLI

Hammond Power Solutions

POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL

NO

.43 A

2.08 A

2

50 VA

NO

25 V

120 V

60 HZ

DUAL 240/480V

3.56 mm

3.25 mm

480/240

4.06 mm

16-1

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

16

YES

1500 V

1 A

1 A

2

73mm X 50.8mm X 58.7mm

YES

8 V

8 V

50/60 HZ

SINGLE 115V

58.7 mm

50.8 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

73 mm

36-50

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

36

YES

1500 V

50 A

50 A

2

162mm X 184.2mm X 134.9mm

YES

18 V

18 V

50/60 HZ

DUAL 115V

134.9 mm

184.2 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

162 mm

715

Hammond Manufacturing

POWER TRANSFORMER

CHASSIS MOUNT

CSA

NO

1

352 VA

YES

1020 V

50/60 HZ

SINGLE 115V

115

115

VPS28-6250

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

CE, CSA, CUL, TUV, UL

NO

2

4000 V

12.5 A

12.5 A

2

L79.38XB71.42XH85.72 (mm)

175 VA

NO

POWER

14 V

14 V

50/60 HZ

DUAL 115V

85.72 mm

71.42 mm

115/230

79.38 mm

PH50MBMH

Hammond Power Solutions

POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL

NO

.43 A

2

50 VA

NO

100 V

120 V

60 HZ

3.63 mm

3.25 mm

600/480/240

4.06 mm

VPL24-210

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

CUL; TUV; UL

NO

2

3500 V

.42 A

.42 A

2

L60.32XB36.5XH36.5 (mm)

5 VA

NO

POWER

12 V

12 V

50/60 HZ

DUAL 115V

36.5 mm

36.5 mm

115/230

60.32 mm

PH75MLI

Hammond Power Solutions

POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL

NO

.65 A

3.13 A

2

75 VA

NO

25 V

120 V

60 HZ

DUAL 240/480V

3.56 mm

3.25 mm

480/240

4.25 mm

F-22A

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

2000 V

20 A

1

Other Transformers

L83.34XB104.77XH98.42 (mm)

126 VA

YES

POWER

6.3 V

50/60 HZ

SINGLE 115V

98.42 mm

104.77 mm

83.34 mm

115

N-48X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

NO

1

1500 V

.13 A

1

Other Transformers

L84.12XB50.8XH49.2 (mm)

15 VA

NO

ISOLATION

115 V

50/60 HZ

SINGLE 115V

49.2 mm

50.8 mm

84.12 mm

115

F-193U

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

4 A

1

Other Transformers

L79.38XB71.42XH71.42 (mm)

96 VA

YES

POWER

24 V

50/60 HZ

SINGLE 115V

71.42 mm

71.42 mm

79.38 mm

115

PH75MGJ

Hammond Power Solutions

POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL

NO

.63 A

.31 A

2

75 VA

NO

240 V

120 V

60 HZ

3.63 mm

3.25 mm

380/277/208

4.19 mm

FD7-36

Triad Magnetics

SPLIT BOBBIN POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

2

2500 V

1.5 A

1

Other Transformers

L68.25XB46.02XH57.15 (mm)

56 VA

YES

POWER

36 V

50/60 HZ

DUAL 115V

57.15 mm

46.02 mm

68.25 mm

16-4

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

16

YES

1500 V

4 A

4 A

2

85.7mm X 69.9mm X 71.4mm

YES

8 V

8 V

50/60 HZ

SINGLE 115V

71.4 mm

69.9 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

85.7 mm

166M16

Hammond Manufacturing

SPLIT BOBBIN POWER TRANSFORMER

CHASSIS MOUNT

CSA; UL

NO

2000 V

3 A

1

48 VA

YES

16 V

60 HZ

SINGLE 115V

58.674 mm

54.102 mm

115

93.726 mm

735

Hammond Manufacturing

POWER TRANSFORMER

CHASSIS MOUNT

CSA

NO

1

735 VA

YES

3000 V

50/60 HZ

SINGLE 115V

115

115

PH100MEMX

Hammond Power Solutions

POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL

NO

.91 A

.45 A

2

100 VA

NO

220 V

110 V

60 HZ

3.63 mm

3.25 mm

415/400/380

4.19 mm

VPS36-3600

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

CE, CSA, CUL, TUV, UL

NO

2

4000 V

7.2 A

7.2 A

2

L71.42XB68.25XH85.72 (mm)

130 VA

NO

POWER

18 V

18 V

50/60 HZ

DUAL 115V

85.72 mm

68.25 mm

115/230

71.42 mm

10-50

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

10

YES

1500 V

50 A

50 A

2

133.4mm X 139.7mm X 111.1mm

YES

5 V

5 V

50/60 HZ

SINGLE 105/115/125V

111.1 mm

139.7 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

133.4 mm

185G36

Hammond Manufacturing

SPLIT BOBBIN POWER TRANSFORMER

CHASSIS MOUNT

CE; CUL; TUV; UL

NO

4000 V

9.6 A

2

175 VA

NO

18 V

18 V

50/60 HZ

DUAL 115/230V

95.25 mm

79.248 mm

115/230

81.28 mm

F-345X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

2

1500 V

1 A

1

Other Transformers

L84.12XB50.8XH49.2 (mm)

24 VA

YES

POWER

24 V

50/60 HZ

SINGLE 115/230V

49.2 mm

50.8 mm

84.12 mm

Power & Mains Transformers

Power and mains transformers are types of electrical transformers used in power transmission and distribution systems to convert high voltage and low current to low voltage and high current or vice versa. They are essential components in the electricity grid, and are used to step up or step down voltage levels for efficient transmission and distribution of electrical energy.

Power transformers are used in high voltage transmission systems, typically at voltages of 110 kV and above, to step up or step down the voltage levels. They have a high power rating, typically ranging from several hundred kVA to several thousand MVA, and are designed to handle high currents and voltages without overheating or breaking down. Power transformers are typically oil-immersed, and use a magnetic core made of laminated steel to reduce losses and improve efficiency.

Mains transformers, also known as distribution transformers, are used in low voltage distribution systems, typically at voltages of 11 kV or below, to step down the voltage levels for use by consumers. They have a lower power rating than power transformers, typically ranging from several kVA to several hundred kVA, and are designed to operate at lower voltages and currents. Mains transformers are typically dry-type, and use a magnetic core made of laminated steel or ferrite to reduce losses and improve efficiency.

Both power and mains transformers require proper design, selection, and maintenance to ensure reliable and efficient operation. They are subject to various standards and regulations, such as IEC (International Electrotechnical Commission) and IEEE (Institute of Electrical and Electronics Engineers), to ensure their safety and performance. Proper installation and maintenance of transformers, such as regular inspection, testing, and oil analysis, are also critical to ensure their longevity and performance.