SURFACE MOUNT Power & Mains Transformers 30

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Power Rating Center Tap Feature-2 No. of Functions No. of Winding (Primary) Isolation Voltage Inductance (Primary) Packing Method Output Current-1 Minimum ET Product Output Current-2 No. of Winding (Secondary) Sub-Category Dimensions Volt-Ampere Rating (VA) Maximum Operating Temperature Center Tap Feature-1 Application Output Voltage-2 Output Voltage-1 Minimum Operating Temperature Nominal Operating Frequency Rating (Primary) Height Width Diameter Nominal Input Voltage (V) Load Resistance Additional Features Minimum Input Voltage (V) JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency Maximum Input Voltage (V)

MA5632-ALB

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

Tin/Silver (Sn/Ag)

NO

2500 V

TR

2

Other Transformers

12.07mm x 8.1mm x 5.97mm

125 Cel

NO

3.3 V

5 V

-40 Cel

DUAL 3.3-5V

5.97 mm

8.1 mm

e2

10.3 mm

MA5632-ALD

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

Tin/Silver - Matte Tin - with Nickel barrier

NO

2500 V

TR, EMBOSSED PLASTIC, 13 INCH

2

Other Transformers

12.07mm x 8.1mm x 5.97mm

125 Cel

NO

3.3 V

5 V

-40 Cel

DUAL 3.3-5V

5.97 mm

8.1 mm

10.3 mm

DA2303-ALD

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

Tin/Silver - Tin - with Nickel barrier

NO

2500 V

TR, EMBOSSED PLASTIC, 13 INCH

2

L12.07XB10.0XH5.97 (mm)

125 Cel

NO

6 V

6 V

-40 Cel

150 KHZ

DUAL 5V

5.97 mm

8.1 mm

5

10.3 mm

PM-DB2745S

Holt Integrated Circuits

POWER TRANSFORMER

SURFACE MOUNT

Tin/Lead (Sn/Pb)

NO

100 V

1

L23.62XB16.0XH3.937 (mm)

130 Cel

YES

-55 Cel

3.937 mm

16 mm

e0

23.62 mm

DA2303-ALB

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

Tin/Silver - Tin - with Nickel barrier

NO

2500 V

TR

2

L12.07XB10.0XH5.97 (mm)

125 Cel

NO

6 V

6 V

-40 Cel

150 KHZ

DUAL 5V

5.97 mm

8.1 mm

5

10.3 mm

ZA9368-AED

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

NO

1

3500 V

256 uH

TR, EMBOSSED PLASTIC, 13 INCH

.7 A

16 V-us

1

125 Cel

YES

ISOLATION

5 V

-40 Cel

SINGLE 3.3V

5.6 mm

8.5 mm

3.3

LENGTH & HEIGHT DIM INCLUDE TERMINAL ALSO

15.2 mm

1:1.75

74942302

Wurth Elektronik

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

YES

4300 V

TR, EMBOSSED PLASTIC, 13 INCH

2

125 Cel

YES

-40 Cel

3.45 mm

14.7 mm

1000

15.1 mm

74942300

Wurth Elektronik

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

YES

4300 V

TR, EMBOSSED PLASTIC, 13 INCH

2

125 Cel

YES

-40 Cel

4.75 mm

14.2 mm

1000

15.1 mm

74941300

Wurth Elektronik

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

NO

4300 V

TR, EMBOSSED PLASTIC, 13 INCH

1

125 Cel

YES

-40 Cel

5.5 mm

7.6 mm

1000

HEIGHT DIM INCLUDES TERMINALS ALSO

8.9 mm

74941302

Wurth Elektronik

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

NO

4300 V

TR, EMBOSSED PLASTIC, 13 INCH

1

125 Cel

YES

-40 Cel

3.45 mm

9.5 mm

1000

14.3 mm

74942301

Wurth Elektronik

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

NO

4300 V

TR, EMBOSSED PLASTIC, 13 INCH

2

125 Cel

NO

-40 Cel

3.45 mm

14.2 mm

1000

15.1 mm

TGM-040P3RL

Halo Electronics

POWER TRANSFORMER

SURFACE MOUNT

CUL; UL

Matte Tin (Sn) - reflowed over Nickel (Ni) barrier

NO

1

500 V

240 uH

5.5 V-us

2

L7.62XB7.11XH2.24 (mm)

85 Cel

NO

GENERAL PURPOSE

-40 Cel

DUAL 5V

2.24 mm

7.11 mm

5

HEIGHT DIM INCLUDES TERMINAL ALSO

e3

7.62 mm

1:1:1.3:1.3

DA2304-ALD

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

Tin/Silver - Tin - with Nickel barrier

7.2 W

NO

2

2500 V

17.8 uH

TR, EMBOSSED PLASTIC, 13 INCH

2

Other Transformers

L12.07XB10.0XH5.97 (mm)

125 Cel

NO

POWER

6 V

6 V

-40 Cel

150 KHZ

DUAL 3.3V

5.97 mm

8.1 mm

3.3

.232 ohm

3.3

10.3 mm

1:2.2

DA2304-ALB

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

Tin/Silver - Tin - with Nickel barrier

7.2 W

NO

2

2500 V

17.8 uH

TR

2

Other Transformers

L12.07XB10.0XH5.97 (mm)

125 Cel

NO

POWER

6 V

6 V

-40 Cel

150 KHZ

DUAL 3.3V

5.97 mm

8.1 mm

3.3

.232 ohm

3.3

10.3 mm

1:2.2

74941301

Wurth Elektronik

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

NO

4300 V

TR, EMBOSSED PLASTIC, 13 INCH

1

125 Cel

NO

-40 Cel

5.5 mm

7.6 mm

1000

8.9 mm

PH9385.011NLT

Pulse Electronics

POWER TRANSFORMER

SURFACE MOUNT

NO

4000 V

TR

2

125 Cel

NO

-40 Cel

7.5 mm

16 mm

17 mm

CTPTF-7801EP13

Central Technologies

POWER TRANSFORMER

SURFACE MOUNT

NO

1500 V

.02 A

2

125 Cel

NO

3.3 V

12 V

-40 Cel

200 KHZ

SINGLE 33-57V

13 mm

14 mm

LENGTH AND HEIGHT DIMENSION INCLUDE TERMINAL ALSO

17.5 mm

84910

Pico Electronics

POWER TRANSFORMER

SURFACE MOUNT

MIL-PRF-27

Tin/Lead (Sn/Pb)

NO

.0353 A

2

L25.4XB20.32XH23.24 (mm)

2.4 VA

90 Cel

YES

68 V

400 HZ

SINGLE 26V

23.24 mm

20.32 mm

26

e0

20.32 mm

76904

Pico Electronics

POWER TRANSFORMER

SURFACE MOUNT

MIL-PRF-27

Tin/Lead (Sn/Pb)

NO

.047 A

2

L17.02XB13.97XH10.54 (mm)

2.4 VA

90 Cel

YES

8 V

400 HZ

SINGLE 26V

10.54 mm

13.97 mm

26

e0

13.97 mm

PM2185.011NL

Pulse Electronics

TOROIDAL POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200: UL

NO

4000 V

TRAY

1

125 Cel

YES

-40 Cel

7.6 mm

8.2 mm

HEIGHT DIM INCLUDES TERMINAL ALSO

9.2 mm

PM2185.012NL

Pulse Electronics

TOROIDAL POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200: UL

NO

4000 V

TRAY

1

125 Cel

YES

-40 Cel

7.6 mm

8.2 mm

HEIGHT DIM INCLUDES TERMINAL ALSO

9.2 mm

JA4631-BLD

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

Tin/Silver - Matte Tin - with Nickel barrier

2 W

NO

2

2500 V

63.75 uH

TR, EMBOSSED PLASTIC, 13 INCH

17.6 V-us

2

Other Transformers

10mm x 8.1mm x 5.97mm

125 Cel

NO

ISOLATION

5 V

-40 Cel

5.97 mm

8.1 mm

5

.19 ohm

10.3 mm

1:2

KA4976-ALB

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

2 W

NO

2

2500 V

63.75 uH

TR

2

125 Cel

NO

15 V

-40 Cel

5.97 mm

8.1 mm

5

10.3 mm

KA4976-ALD

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

Tin/Silver - Matte Tin - with Nickel barrier

2 W

NO

2

2500 V

63.75 uH

TR, EMBOSSED PLASTIC, 13 INCH

2

125 Cel

NO

15 V

-40 Cel

5.97 mm

8.1 mm

5

10.3 mm

ATB322524-0110-T000

TDK

POWER TRANSFORMER

SURFACE MOUNT

NO

500 V

TR, 7 INCH

1

L3.2XB2.5XH2.4 (mm)

85 Cel

NO

-40 Cel

2.4 mm

2.5 mm

TURNS RATIO: 1:10.2

3.2 mm

CTX110603-R

Eaton Corporation

POWER TRANSFORMER

SURFACE MOUNT

NO

BULK

.011 A

2

L21.0XB16.5XH5.9 (mm)

6 VA

70 Cel

NO

1340 V

0 Cel

5.9 mm

16.5 mm

21 mm

CTX110607-R

Eaton Corporation

POWER TRANSFORMER

SURFACE MOUNT

NO

BULK

.011 A

2

L21.0XB16.5XH5.9 (mm)

6 VA

70 Cel

NO

1340 V

0 Cel

5.9 mm

16.5 mm

21 mm

JA4650-BLD

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

Tin/Silver - Matte Tin - with Nickel barrier

2 W

NO

2

2500 V

63.75 uH

TR, EMBOSSED PLASTIC, 13 INCH

2

125 Cel

NO

7.5 V

15 V

-40 Cel

5.97 mm

8.1 mm

5

10.3 mm

PA6547-ALD

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

Tin/Silver - Matte Tin - with Nickel barrier

NO

2500 V

TR, EMBOSSED PLASTIC, 13 INCH

2

125 Cel

NO

3.3 V

5 V

-40 Cel

DUAL 5V

5.97 mm

8.1 mm

5

10.3 mm

PA6549-ALD

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

NO

2500 V

TR, EMBOSSED PLASTIC, 13 INCH

2

125 Cel

NO

12 V

15 V

-40 Cel

DUAL 5V

5.97 mm

8.1 mm

5

10.3 mm

Power & Mains Transformers

Power and mains transformers are types of electrical transformers used in power transmission and distribution systems to convert high voltage and low current to low voltage and high current or vice versa. They are essential components in the electricity grid, and are used to step up or step down voltage levels for efficient transmission and distribution of electrical energy.

Power transformers are used in high voltage transmission systems, typically at voltages of 110 kV and above, to step up or step down the voltage levels. They have a high power rating, typically ranging from several hundred kVA to several thousand MVA, and are designed to handle high currents and voltages without overheating or breaking down. Power transformers are typically oil-immersed, and use a magnetic core made of laminated steel to reduce losses and improve efficiency.

Mains transformers, also known as distribution transformers, are used in low voltage distribution systems, typically at voltages of 11 kV or below, to step down the voltage levels for use by consumers. They have a lower power rating than power transformers, typically ranging from several kVA to several hundred kVA, and are designed to operate at lower voltages and currents. Mains transformers are typically dry-type, and use a magnetic core made of laminated steel or ferrite to reduce losses and improve efficiency.

Both power and mains transformers require proper design, selection, and maintenance to ensure reliable and efficient operation. They are subject to various standards and regulations, such as IEC (International Electrotechnical Commission) and IEEE (Institute of Electrical and Electronics Engineers), to ensure their safety and performance. Proper installation and maintenance of transformers, such as regular inspection, testing, and oil analysis, are also critical to ensure their longevity and performance.