Part | RoHS | Manufacturer | Transformer Type | Mounting Feature | Manufacturer Series | Approvals (V) | Terminal Finish | Power Rating | Center Tap Feature-2 | No. of Functions | No. of Winding (Primary) | Isolation Voltage | Inductance (Primary) | Packing Method | Output Current-1 | Minimum ET Product | Output Current-2 | No. of Winding (Secondary) | Sub-Category | Dimensions | Volt-Ampere Rating (VA) | Maximum Operating Temperature | Center Tap Feature-1 | Application | Output Voltage-2 | Output Voltage-1 | Minimum Operating Temperature | Nominal Operating Frequency | Rating (Primary) | Height | Width | Diameter | Nominal Input Voltage (V) | Load Resistance | Additional Features | Minimum Input Voltage (V) | JESD-609 Code | Minimum Operating Frequency | Length | Turns Ratio (Np:Ns) | Maximum Operating Frequency | Maximum Input Voltage (V) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL |
NO |
2 |
2000 V |
1 A |
1 A |
2 |
L63.5XB50.8XH26.97 (mm) |
12 VA |
NO |
POWER |
12 V |
12 V |
50/60 HZ |
DUAL 115/230V |
26.97 mm |
50.8 mm |
115/230 |
PCB MOUNTABLE |
63.5 mm |
|||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
UL |
NO |
2 |
2500 V |
1.5 A |
1 |
Other Transformers |
L68.25XB46.02XH57.15 (mm) |
56 VA |
YES |
POWER |
36 V |
50/60 HZ |
DUAL 115V |
57.15 mm |
46.02 mm |
68.25 mm |
||||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
CSA; UL |
NO |
2000 V |
3 A |
1 |
48 VA |
YES |
16 V |
60 HZ |
SINGLE 115V |
58.674 mm |
54.102 mm |
115 |
93.726 mm |
|||||||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL |
NO |
2 |
2500 V |
3.2 A |
3.2 A |
2 |
L57.15XB47.62XH36.5 (mm) |
20 VA |
NO |
POWER |
6.3 V |
6.3 V |
50/60 HZ |
DUAL 115V |
36.5 mm |
47.62 mm |
115/230 |
57.15 mm |
||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
CE; CUL; TUV; UL |
NO |
4000 V |
9.6 A |
2 |
175 VA |
NO |
18 V |
18 V |
50/60 HZ |
DUAL 115/230V |
95.25 mm |
79.248 mm |
115/230 |
81.28 mm |
||||||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
UL |
NO |
1 |
1500 V |
1.67 A |
1 |
Other Transformers |
D92.5XH56.5 (mm) |
40 VA |
NO |
POWER |
24 V |
50/60 HZ |
SINGLE 120V |
56.5 mm |
59.44 mm |
92.5 mm |
92.46 mm |
120 |
||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
CUL; CSA,TUV, UL |
YES |
2 |
4000 V |
14.6 A |
14.6 A |
2 |
L79.38XB71.42XH85.72 (mm) |
175 VA |
YES |
POWER |
12 V |
12 V |
50/60 HZ |
DUAL 115V |
85.72 mm |
71.42 mm |
115/230 |
79.38 mm |
||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
CE, CSA, CUL, TUV, UL |
NO |
2 |
4000 V |
1.8 A |
1.8 A |
2 |
L71.42XB49.2XH58.72 (mm) |
25 VA |
NO |
POWER |
14 V |
14 V |
50/60 HZ |
DUAL 115V |
58.72 mm |
49.2 mm |
115/230 |
71.42 mm |
||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL |
YES |
1 |
2500 V |
.22 A |
.22 A |
2 |
L34.92XB28.57XH23.8 (mm) |
1.1 VA |
YES |
POWER |
5 V |
5 V |
50/60 HZ |
SINGLE 115V |
23.8 mm |
28.57 mm |
115 |
34.92 mm |
||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CE; CUL; TUV; UL |
NO |
4200 V |
.09 A |
2 |
1.1 VA |
115 Cel |
NO |
6.3 V |
6.3 V |
-40 Cel |
50/60 HZ |
DUAL 115V |
25.4 mm |
30.51 mm |
115/230 |
35.99 mm |
||||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
NO |
4200000 V |
.12 A |
.12 A |
2 |
L34.92XB28.57XH23.8 (mm) |
2.5 VA |
NO |
10 V |
10 V |
50/60 HZ |
DUAL 115V |
23.8 mm |
28.57 mm |
34.92 mm |
||||||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
PCB MOUNT |
CUL; UL |
NO |
2500 V |
.24 A |
2 |
2.4 VA |
NO |
10 V |
10 V |
50/60 HZ |
SINGLE 115V |
30.226 mm |
28.702 mm |
115 |
35.052 mm |
||||||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
PCB MOUNT |
CUL; UL |
NO |
2500 V |
.2 A |
2 |
2.4 VA |
NO |
12 V |
12 V |
50/60 HZ |
SINGLE 115V |
30.226 mm |
28.702 mm |
115 |
35.052 mm |
||||||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
PCB MOUNT |
CUL; UL |
NO |
2500 V |
.17 A |
2 |
2.4 VA |
NO |
14 V |
14 V |
50/60 HZ |
SINGLE 115V |
30.226 mm |
28.702 mm |
115 |
35.052 mm |
||||||||||||||||||||||||
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
CSA; UL |
NO |
2000 V |
.5 A |
1 |
14 VA |
YES |
28 V |
60 HZ |
SINGLE 115V |
42.926 mm |
41.402 mm |
115 |
71.374 mm |
||||||||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CUL; UL |
NO |
1750 V |
4 A |
2 |
48 VA |
NO |
12 V |
12 V |
50/60 HZ |
DUAL 115V |
35.052 mm |
63.5 mm |
115/230 |
79.248 mm |
||||||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL |
NO |
2 |
2500 V |
.24 A |
.24 A |
2 |
L34.92XB28.57XH23.8 (mm) |
2.5 VA |
NO |
POWER |
10 V |
10 V |
50/60 HZ |
DUAL 115V |
23.8 mm |
28.57 mm |
115/230 |
34.92 mm |
||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
NO |
4200000 V |
BULK |
.12 A |
.12 A |
2 |
L34.92XB28.57XH23.8 (mm) |
2.5 VA |
NO |
10 V |
10 V |
50/60 HZ |
DUAL 115V |
23.8 mm |
28.57 mm |
34.92 mm |
|||||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
PCB MOUNT |
CSA; UL |
NO |
2000 V |
1 A |
2 |
10 VA |
NO |
10 V |
60 HZ |
SINGLE 115V |
42.926 mm |
36.576 mm |
115 |
49.276 mm |
|||||||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
CSA; UL |
NO |
2000 V |
.5 A |
1 |
15 VA |
YES |
30 V |
60 HZ |
SINGLE 115V |
50.8 mm |
41.402 mm |
115 |
82.55 mm |
|||||||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
CSA; UL |
NO |
2000 V |
1 A |
1 |
28 VA |
YES |
28 V |
60 HZ |
SINGLE 115V |
50.8 mm |
50.8 mm |
115 |
82.55 mm |
|||||||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
CSA; UL |
NO |
2000 V |
2 A |
1 |
56 VA |
YES |
28 V |
60 HZ |
SINGLE 115V |
58.674 mm |
54.102 mm |
115 |
93.726 mm |
|||||||||||||||||||||||||
|
Hahn And Kg |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL; CSA; VDE |
BULK |
.5 A |
1 |
3 VA |
40 Cel |
NO |
6 V |
SINGLE 230V |
30 mm |
27.8 mm |
230 |
32.8 mm |
||||||||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL |
NO |
2 |
2500 V |
1 A |
1 A |
2 |
L47.62XB39.67XH36.5 (mm) |
12 VA |
NO |
POWER |
12 V |
12 V |
50/60 HZ |
DUAL 115V |
36.5 mm |
39.67 mm |
115/230 |
47.62 mm |
||||||||||||||||||||
|
Bel Fuse |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL; CSA |
NO |
2500 V |
.11 A |
.11 A |
2 |
L34.9XB28.6XH24.6 (mm) |
1.1 VA |
NO |
5 V |
5 V |
50/60 HZ |
SINGLE 115V |
24.6 mm |
28.6 mm |
34.9 mm |
|||||||||||||||||||||||
|
Bel Fuse |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL; CSA |
NO |
2500 V |
.09 A |
.09 A |
2 |
L34.9XB28.6XH24.6 (mm) |
1.1 VA |
NO |
6.3 V |
6.3 V |
50/60 HZ |
SINGLE 115V |
24.6 mm |
28.6 mm |
34.9 mm |
|||||||||||||||||||||||
|
Bel Fuse |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CE, CSA, VDE, UL |
NO |
4000 V |
1 A |
1 A |
2 |
L57.2XB47.6XH41.3 (mm) |
20 VA |
NO |
10 V |
10 V |
50/60 HZ |
DUAL 115V |
41.3 mm |
47.6 mm |
115/230 |
57.2 mm |
||||||||||||||||||||||
|
Oep Walters Group Holdings |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
NO |
1000000 V |
2 |
L27.94XB22.9XH22.2 (mm) |
70 Cel |
NO |
-20 Cel |
300 HZ |
22.2 mm |
22.9 mm |
27.94 mm |
||||||||||||||||||||||||||||
|
Bel Fuse |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL; CSA |
NO |
2500 V |
.045 A |
.045 A |
2 |
L34.9XB28.6XH24.6 (mm) |
1.1 VA |
NO |
12 V |
12 V |
50/60 HZ |
DUAL 115/230V |
24.6 mm |
28.6 mm |
34.9 mm |
|||||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
NO |
4200000 V |
.2 A |
.2 A |
2 |
L34.92XB28.57XH23.8 (mm) |
2.5 VA |
NO |
6.3 V |
6.3 V |
50/60 HZ |
DUAL 115V |
23.8 mm |
28.57 mm |
34.92 mm |
||||||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
PCB MOUNT |
CSA; UL |
NO |
2000 V |
.36 A |
2 |
4.4 VA |
NO |
12 V |
50/60 HZ |
DUAL 115/230V |
36.83 mm |
31.75 mm |
115/230 |
42.926 mm |
|||||||||||||||||||||||||
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
PCB MOUNT |
CUL; UL |
NO |
2500 V |
.22 A |
2 |
1.1 VA |
NO |
5 V |
5 V |
50/60 HZ |
DUAL 115V |
23.8125 mm |
28.702 mm |
115/230 |
35.052 mm |
|||||||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
PCB MOUNT |
CUL; UL |
NO |
2500 V |
1 A |
2 |
6 VA |
NO |
6.3 V |
6.3 V |
50/60 HZ |
DUAL 115V |
33.274 mm |
33.274 mm |
115/230 |
41.402 mm |
||||||||||||||||||||||||
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
CSA; UL |
NO |
2000 V |
8 A |
1 |
80 VA |
YES |
10 V |
60 HZ |
SINGLE 115V |
66.802 mm |
63.5 mm |
115 |
102.362 mm |
||||||||||||||||||||||||||
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
CSA; UL |
NO |
2000 V |
6.25 A |
1 |
100 VA |
YES |
16 V |
50/60 HZ |
SINGLE 115V |
65.024 mm |
57.15 mm |
115 |
102.362 mm |
||||||||||||||||||||||||||
|
Hahn And Kg |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL; CSA; VDE |
BULK |
.033 A |
1 |
.5 VA |
70 Cel |
NO |
15 V |
SINGLE 230V |
15.5 mm |
27.8 mm |
230 |
32.8 mm |
||||||||||||||||||||||||||
|
Hahn And Kg |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL; CSA; VDE |
BULK |
.1 A |
1 |
1.5 VA |
70 Cel |
NO |
15 V |
SINGLE 230V |
22.1 mm |
27.8 mm |
230 |
32.8 mm |
||||||||||||||||||||||||||
|
Hahn And Kg |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL; CSA; VDE |
BULK |
.434 A |
1 |
2.6 VA |
40 Cel |
NO |
6 V |
SINGLE 230V |
27.3 mm |
27.8 mm |
230 |
32.8 mm |
||||||||||||||||||||||||||
|
Hahn And Kg |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL; CSA; VDE |
BULK |
.174 A |
1 |
2.6 VA |
40 Cel |
NO |
15 V |
SINGLE 230V |
27.3 mm |
27.8 mm |
230 |
32.8 mm |
||||||||||||||||||||||||||
|
Bel Fuse |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
UL; CSA |
NO |
2 |
2500 V |
2 A |
1 |
Other Transformers |
L82.6XB28.9XH49.8 (mm) |
30 VA |
YES |
POWER |
16 V |
50/60 HZ |
DUAL 115/230V |
49.8 mm |
28.9 mm |
TWO-4-ONE, HIGH ISOLATION |
82.6 mm |
|||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
NO |
4200000 V |
.12 A |
.12 A |
2 |
L34.92XB28.57XH30.15 (mm) |
2.5 VA |
NO |
10 V |
10 V |
50/60 HZ |
SINGLE 115V |
30.15 mm |
28.57 mm |
34.92 mm |
||||||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL |
NO |
2 |
2500 V |
2.4 A |
2.4 A |
2 |
L47.62XB39.67XH36.5 (mm) |
12 VA |
NO |
POWER |
5 V |
5 V |
50/60 HZ |
DUAL 115V |
36.5 mm |
39.67 mm |
115/230 |
47.62 mm |
||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
NO |
4200000 V |
1.2 A |
1.2 A |
2 |
L47.62XB39.67XH36.5 (mm) |
12 VA |
NO |
5 V |
5 V |
50/60 HZ |
DUAL 115V |
36.5 mm |
39.67 mm |
47.62 mm |
||||||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CUL; CSA,TUV, UL |
NO |
2 |
4000 V |
1.66 A |
1.66 A |
2 |
L57.15XB47.62XH41.27 (mm) |
20 VA |
NO |
POWER |
12 V |
12 V |
50/60 HZ |
DUAL 115V |
41.27 mm |
47.62 mm |
57.15 mm |
|||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
PCB MOUNT |
CSA; UL |
NO |
2000 V |
.72 A |
2 |
10 VA |
NO |
14 V |
50/60 HZ |
DUAL 115/230V |
42.926 mm |
36.576 mm |
115/230 |
49.276 mm |
|||||||||||||||||||||||||
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
PCB MOUNT |
CUL; UL |
NO |
2500 V |
2.5 A |
2 |
20 VA |
NO |
8 V |
8 V |
50/60 HZ |
DUAL 115V |
36.576 mm |
47.752 mm |
115/230 |
57.15 mm |
|||||||||||||||||||||||||
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CE; CUL; TUV; UL |
NO |
4000 V |
2.5 A |
2 |
20 VA |
NO |
8 V |
8 V |
50/60 HZ |
DUAL 115V |
41.402 mm |
47.752 mm |
57.15 mm |
||||||||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
NO |
4200000 V |
.1 A |
.1 A |
2 |
L34.92XB28.57XH30.15 (mm) |
2.5 VA |
NO |
12 V |
12 V |
50/60 HZ |
SINGLE 115V |
30.15 mm |
28.57 mm |
34.92 mm |
Power and mains transformers are types of electrical transformers used in power transmission and distribution systems to convert high voltage and low current to low voltage and high current or vice versa. They are essential components in the electricity grid, and are used to step up or step down voltage levels for efficient transmission and distribution of electrical energy.
Power transformers are used in high voltage transmission systems, typically at voltages of 110 kV and above, to step up or step down the voltage levels. They have a high power rating, typically ranging from several hundred kVA to several thousand MVA, and are designed to handle high currents and voltages without overheating or breaking down. Power transformers are typically oil-immersed, and use a magnetic core made of laminated steel to reduce losses and improve efficiency.
Mains transformers, also known as distribution transformers, are used in low voltage distribution systems, typically at voltages of 11 kV or below, to step down the voltage levels for use by consumers. They have a lower power rating than power transformers, typically ranging from several kVA to several hundred kVA, and are designed to operate at lower voltages and currents. Mains transformers are typically dry-type, and use a magnetic core made of laminated steel or ferrite to reduce losses and improve efficiency.
Both power and mains transformers require proper design, selection, and maintenance to ensure reliable and efficient operation. They are subject to various standards and regulations, such as IEC (International Electrotechnical Commission) and IEEE (Institute of Electrical and Electronics Engineers), to ensure their safety and performance. Proper installation and maintenance of transformers, such as regular inspection, testing, and oil analysis, are also critical to ensure their longevity and performance.