Part | RoHS | Manufacturer | Transformer Type | Mounting Feature | Manufacturer Series | Approvals (V) | Terminal Finish | Power Rating | Center Tap Feature-2 | No. of Functions | No. of Winding (Primary) | Isolation Voltage | Inductance (Primary) | Packing Method | Output Current-1 | Minimum ET Product | Output Current-2 | No. of Winding (Secondary) | Sub-Category | Dimensions | Volt-Ampere Rating (VA) | Maximum Operating Temperature | Center Tap Feature-1 | Application | Output Voltage-2 | Output Voltage-1 | Minimum Operating Temperature | Nominal Operating Frequency | Rating (Primary) | Height | Width | Diameter | Nominal Input Voltage (V) | Load Resistance | Additional Features | Minimum Input Voltage (V) | JESD-609 Code | Minimum Operating Frequency | Length | Turns Ratio (Np:Ns) | Maximum Operating Frequency | Maximum Input Voltage (V) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Emerson Electric |
POWER TRANSFORMER |
CHASSIS MOUNT |
UL; CSA; IEC; CE |
NO |
2 |
L171.45XB162.05XH143.0 (mm) |
1500 VA |
NO |
115 V |
230 V |
50/60 HZ |
SINGLE 200/230/400/460/575V |
143 mm |
162.05 mm |
171.45 mm |
||||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
CHASSIS MOUNT |
CSA, CUL, EAC |
NO |
1 |
750 VA |
40 Cel |
NO |
120 V |
DUAL 240V |
165.4 mm |
132 mm |
240 |
150 mm |
||||||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
CHASSIS MOUNT |
CSA, CUL, EAC |
NO |
1 |
750 VA |
40 Cel |
NO |
120 V |
SINGLE 600V |
162.7 mm |
132 mm |
600 |
150 mm |
||||||||||||||||||||||||||||
|
Bel Fuse |
SPLIT BOBBIN POWER TRANSFORMER |
CHASSIS MOUNT |
UL; CSA |
NO |
2 |
2500 V |
2 A |
1 |
Other Transformers |
L82.6XB28.9XH49.8 (mm) |
30 VA |
YES |
POWER |
16 V |
50/60 HZ |
DUAL 115/230V |
49.8 mm |
28.9 mm |
TWO-4-ONE, HIGH ISOLATION |
82.6 mm |
|||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
NO |
4200000 V |
.12 A |
.12 A |
2 |
L34.92XB28.57XH30.15 (mm) |
2.5 VA |
NO |
10 V |
10 V |
50/60 HZ |
SINGLE 115V |
30.15 mm |
28.57 mm |
34.92 mm |
||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA; CUL; EAC; UL; VDE |
NO |
2 |
14 VA |
40 Cel |
NO |
12 V |
12 V |
50-60 HZ |
DUAL 115V |
24.384 mm |
56.896 mm |
115 |
68.072 mm |
||||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA; CUL; EAC; UL; VDE |
NO |
2 |
24 VA |
40 Cel |
NO |
15 V |
15 V |
50/60 HZ |
DUAL 115V |
31.496 mm |
56.896 mm |
115 |
68.072 mm |
||||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA; CUL; EAC; UL; VDE |
NO |
2 |
30 VA |
40 Cel |
NO |
12 V |
12 V |
50-60 HZ |
DUAL 115V |
35.814 mm |
56.896 mm |
115 |
68.072 mm |
||||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
VDE |
NO |
2 |
35 VA |
40 Cel |
NO |
12 V |
12 V |
50-60 HZ |
SINGLE 230V |
39 mm |
70 mm |
230 |
83.5 mm |
||||||||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL |
NO |
2 |
2500 V |
2.4 A |
2.4 A |
2 |
L47.62XB39.67XH36.5 (mm) |
12 VA |
NO |
POWER |
5 V |
5 V |
50/60 HZ |
DUAL 115V |
36.5 mm |
39.67 mm |
115/230 |
47.62 mm |
||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
NO |
4200000 V |
1.2 A |
1.2 A |
2 |
L47.62XB39.67XH36.5 (mm) |
12 VA |
NO |
5 V |
5 V |
50/60 HZ |
DUAL 115V |
36.5 mm |
39.67 mm |
47.62 mm |
||||||||||||||||||||||||
Jm Transformer |
POWER TRANSFORMER |
1.9 A |
1 |
60 HZ |
PCB MOUNTABLE |
|||||||||||||||||||||||||||||||||||||
Acme Electric |
POWER TRANSFORMER |
UL; CSA |
41.6 A |
1 |
1000 VA |
60 HZ |
||||||||||||||||||||||||||||||||||||
Stancor Products |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, TUV, UL |
3.2 A |
20 VA |
6.3 V |
6.3 V |
DUAL 115V |
41.402 mm |
47.752 mm |
115/230 |
57.15 mm |
||||||||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, EAC, IEC, UL, VDE |
NO |
1 |
1.2 VA |
70 Cel |
NO |
6 V |
50-60 HZ |
SINGLE 230V |
23.8 mm |
27.3 mm |
230 |
.05 KHz |
32.3 mm |
.06 KHz |
|||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA; CUL; EAC; UL; VDE |
NO |
2 |
3.2 VA |
50 Cel |
NO |
6 V |
6 V |
50-60 HZ |
SINGLE 230V |
30.734 mm |
35.052 mm |
230 |
40.894 mm |
||||||||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CUL; CSA,TUV, UL |
NO |
2 |
4000 V |
1.66 A |
1.66 A |
2 |
L57.15XB47.62XH41.27 (mm) |
20 VA |
NO |
POWER |
12 V |
12 V |
50/60 HZ |
DUAL 115V |
41.27 mm |
47.62 mm |
57.15 mm |
|||||||||||||||||||||
Vigortronix Uk |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CE |
NO |
4200 V |
1 A |
2 |
12 VA |
NO |
6 V |
6 V |
50/60 HZ |
DUAL 115V |
39 mm |
45 mm |
115/230 |
54 mm |
|||||||||||||||||||||||||
|
Multicomp Pro |
TOROIDAL POWER TRANSFORMER |
CHASSIS MOUNT |
NO |
.6 A |
.6 A |
2 |
D74.0XH31.0 (mm) |
30 VA |
NO |
25 V |
25 V |
SINGLE 230V |
31 mm |
74 mm |
|||||||||||||||||||||||||||
Amecon |
TOROIDAL POWER TRANSFORMER |
4.17 A |
1 |
75 VA |
60 HZ |
|||||||||||||||||||||||||||||||||||||
Amecon |
TOROIDAL POWER TRANSFORMER |
3.13 A |
1 |
75 VA |
60 HZ |
|||||||||||||||||||||||||||||||||||||
|
Hammond Manufacturing |
TOROIDAL POWER TRANSFORMER |
CHASSIS MOUNT |
CE; CSA; IEC; UL |
NO |
4000 V |
6.82 A |
2 |
750 VA |
NO |
110 V |
110 V |
50/60 HZ |
DUAL 117/234V |
60.452 mm |
149.352 mm |
117/234 |
|||||||||||||||||||||||||
|
Bel Fuse |
POWER TRANSFORMER |
CHASSIS MOUNT |
YES |
1500 V |
2 A |
2 A |
2 |
L76.2XB63.5XH63.5 (mm) |
YES |
6.4 V |
6.4 V |
50/60 HZ |
SINGLE 115V |
63.5 mm |
63.5 mm |
THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS |
76.2 mm |
||||||||||||||||||||||||
|
Bel Fuse |
POWER TRANSFORMER |
CHASSIS MOUNT |
YES |
1500 V |
6 A |
6 A |
2 |
L85.7XB77.7XH71.4 (mm) |
YES |
6.4 V |
6.4 V |
50/60 HZ |
SINGLE 115V |
71.4 mm |
77.7 mm |
THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS |
85.7 mm |
||||||||||||||||||||||||
|
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
PCB MOUNT |
CSA; UL |
NO |
2000 V |
.72 A |
2 |
10 VA |
NO |
14 V |
50/60 HZ |
DUAL 115/230V |
42.926 mm |
36.576 mm |
115/230 |
49.276 mm |
|||||||||||||||||||||||||
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
PCB MOUNT |
CUL; UL |
NO |
2500 V |
2.5 A |
2 |
20 VA |
NO |
8 V |
8 V |
50/60 HZ |
DUAL 115V |
36.576 mm |
47.752 mm |
115/230 |
57.15 mm |
|||||||||||||||||||||||||
|
Hammond Manufacturing |
POWER TRANSFORMER |
CHASSIS MOUNT |
NO |
2000 V |
1 |
105 Cel |
NO |
-40 Cel |
58.6232 mm |
60.96 mm |
.07 KHz |
93.6752 mm |
15 KHz |
||||||||||||||||||||||||||||
Hammond Manufacturing |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CE; CUL; TUV; UL |
NO |
4000 V |
2.5 A |
2 |
20 VA |
NO |
8 V |
8 V |
50/60 HZ |
DUAL 115V |
41.402 mm |
47.752 mm |
57.15 mm |
||||||||||||||||||||||||||
|
Bel Fuse |
POWER TRANSFORMER |
CHASSIS MOUNT |
24 |
YES |
1500 V |
6 A |
6 A |
2 |
104.8mm X 82.6mm X 87.3mm |
YES |
12 V |
12 V |
50/60 HZ |
SINGLE 115V |
87.3 mm |
82.6 mm |
THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS |
104.8 mm |
|||||||||||||||||||||||
|
Bel Fuse |
POWER TRANSFORMER |
CHASSIS MOUNT |
36 |
YES |
1500 V |
25 A |
25 A |
2 |
162mm X 146.1mm X 134.9mm |
YES |
18 V |
18 V |
50/60 HZ |
SINGLE 105/115/125V |
134.9 mm |
146.1 mm |
THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS |
162 mm |
|||||||||||||||||||||||
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL, VDE |
NO |
4000 V |
.125 A |
.125 A |
2 |
3 VA |
70 Cel |
NO |
12 V |
12 V |
DUAL 115V |
17 mm |
44 mm |
115 |
PARALLEL CONNECTED |
53 mm |
||||||||||||||||||||||
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL |
NO |
4000 V |
.6 A |
.6 A |
2 |
18 VA |
50 Cel |
NO |
15 V |
15 V |
DUAL 115V |
27 mm |
57 mm |
115 |
PARALLEL CONNECTED |
68 mm |
||||||||||||||||||||||
|
Bel Fuse |
POWER TRANSFORMER |
CHASSIS MOUNT |
YES |
1500 V |
12 A |
12 A |
2 |
L133.4XB108XH111.1 (mm) |
YES |
28 V |
28 V |
50/60 HZ |
SINGLE 115V |
111.1 mm |
108 mm |
THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS |
133.4 mm |
||||||||||||||||||||||||
|
Hammond Manufacturing |
POWER TRANSFORMER |
CHASSIS MOUNT |
CSA |
NO |
1 |
750 VA |
YES |
2500 V |
50/60 HZ |
SINGLE 115V |
161.5694 mm |
134.1374 mm |
115 |
145.3134 mm |
115 |
||||||||||||||||||||||||||
|
Triad Magnetics |
SPLIT BOBBIN POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
NO |
4200000 V |
.1 A |
.1 A |
2 |
L34.92XB28.57XH30.15 (mm) |
2.5 VA |
NO |
12 V |
12 V |
50/60 HZ |
SINGLE 115V |
30.15 mm |
28.57 mm |
34.92 mm |
||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
VDE |
NO |
2 |
6 VA |
40 Cel |
NO |
15 V |
15 V |
50-60 HZ |
SINGLE 230V |
28.6 mm |
44 mm |
230 |
53 mm |
||||||||||||||||||||||||||
|
Coilcraft |
POWER TRANSFORMER |
SURFACE MOUNT |
Tin/Silver - Matte Tin - with Nickel barrier |
2 W |
NO |
2 |
2500 V |
63.75 uH |
TR, EMBOSSED PLASTIC, 13 INCH |
17.6 V-us |
2 |
Other Transformers |
10mm x 8.1mm x 5.97mm |
125 Cel |
NO |
ISOLATION |
5 V |
-40 Cel |
5.97 mm |
8.1 mm |
5 |
.19 ohm |
10.3 mm |
1:2 |
|||||||||||||||||
|
Tamura |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, TUV, UL |
NO |
4 A |
.68 A |
2 |
56 VA |
YES |
9.3 V |
27.5 V |
50/60 HZ |
DUAL 115V |
48.5 mm |
64 mm |
115/230 |
76.2 mm |
||||||||||||||||||||||||
Acme Electric |
POWER TRANSFORMER |
UL; CSA |
1 |
15000 VA |
60 HZ |
|||||||||||||||||||||||||||||||||||||
Stancor Products |
POWER TRANSFORMER |
CHASSIS MOUNT |
CSA, TUV, UL |
3.6 A |
43 VA |
12 V |
12 V |
DUAL 115V |
69.85 mm |
49.276 mm |
115/230 |
82.55 mm |
||||||||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
CHASSIS MOUNT |
CSA; CUL; EAC; UL |
NO |
2 |
5000 VA |
40 Cel |
NO |
115 V |
115 V |
50-60 HZ |
SINGLE 208-600V |
160.02 mm |
137.922 mm |
208-600 |
173.99 mm |
||||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, EAC, IEC, UL, VDE |
NO |
1 |
2.3 VA |
40 Cel |
NO |
9 V |
50-60 HZ |
SINGLE 230V |
29 mm |
27.3 mm |
230 |
.05 KHz |
32.3 mm |
.06 KHz |
|||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, EAC, IEC, UL, VDE |
NO |
2 |
3.2 VA |
50 Cel |
NO |
18 V |
18 V |
50-60 HZ |
SINGLE 230V |
30.8 mm |
35 mm |
230 |
.05 KHz |
41 mm |
.06 KHz |
||||||||||||||||||||||||
Block Transformatoren-elektronik |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA; CUL; EAC; UL; VDE |
NO |
1 |
5 VA |
50 Cel |
NO |
6 V |
50-60 HZ |
SINGLE 230V |
33.02 mm |
1.46 mm |
230 |
43.942 mm |
|||||||||||||||||||||||||||
|
Triad Magnetics |
TOROIDAL POWER TRANSFORMER |
CHASSIS MOUNT |
CE, CUL, UL |
TIN |
NO |
2 |
4000 V |
50 A |
50 A |
2 |
D208.0XH112.0 (mm) |
2500 VA |
NO |
POWER |
50 V |
50 V |
50/60 HZ |
DUAL 115V |
120 mm |
210 mm |
115/230 |
e3 |
|||||||||||||||||||
Vigortronix Uk |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CE |
NO |
4200 V |
.25 A |
2 |
6 VA |
NO |
12 V |
12 V |
50/60 HZ |
DUAL 115V |
32 mm |
36 mm |
115/230 |
43 mm |
|||||||||||||||||||||||||
|
Multicomp Pro |
TOROIDAL POWER TRANSFORMER |
CHASSIS MOUNT |
NO |
.83 A |
.83 A |
2 |
D74.0XH31.0 (mm) |
30 VA |
NO |
18 V |
18 V |
SINGLE 230V |
31 mm |
74 mm |
|||||||||||||||||||||||||||
|
Hahn And Kg |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL |
NO |
BULK |
.375 A |
2 |
4.5 VA |
70 Cel |
NO |
6 V |
6 V |
SINGLE 230V |
28.6 mm |
35.5 mm |
230 |
41.3 mm |
Power and mains transformers are types of electrical transformers used in power transmission and distribution systems to convert high voltage and low current to low voltage and high current or vice versa. They are essential components in the electricity grid, and are used to step up or step down voltage levels for efficient transmission and distribution of electrical energy.
Power transformers are used in high voltage transmission systems, typically at voltages of 110 kV and above, to step up or step down the voltage levels. They have a high power rating, typically ranging from several hundred kVA to several thousand MVA, and are designed to handle high currents and voltages without overheating or breaking down. Power transformers are typically oil-immersed, and use a magnetic core made of laminated steel to reduce losses and improve efficiency.
Mains transformers, also known as distribution transformers, are used in low voltage distribution systems, typically at voltages of 11 kV or below, to step down the voltage levels for use by consumers. They have a lower power rating than power transformers, typically ranging from several kVA to several hundred kVA, and are designed to operate at lower voltages and currents. Mains transformers are typically dry-type, and use a magnetic core made of laminated steel or ferrite to reduce losses and improve efficiency.
Both power and mains transformers require proper design, selection, and maintenance to ensure reliable and efficient operation. They are subject to various standards and regulations, such as IEC (International Electrotechnical Commission) and IEEE (Institute of Electrical and Electronics Engineers), to ensure their safety and performance. Proper installation and maintenance of transformers, such as regular inspection, testing, and oil analysis, are also critical to ensure their longevity and performance.