Matte Tin (Sn) - with Nickel (Ni) barrier Pulse & Datacom Transformers 4

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Impedance (Primary) Power Rating No. of Functions Impedance (Secondary) No. of Winding (Primary) Maximum Pulse Rise Time Isolation Voltage Insertion Loss Inductance (Primary) Packing Method Output Current-1 Minimum ET Product Output Current-2 Maximum DC Unbalance Current No. of Winding (Secondary) Sub-Category Dimensions Maximum Operating Temperature Application Output Voltage-1 Minimum Operating Temperature Height Width Nominal Input Voltage (V) Load Resistance Additional Features Minimum Input Voltage (V) JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency Maximum Input Voltage (V)

HX5008FNL

Pulse Electronics

DATACOM TRANSFORMER

SURFACE MOUNT

UL

Matte Tin (Sn) - with Nickel (Ni) barrier

4

1500 V

3 dB

325 uH

Other Transformers

L17.86XB13.16XH6.12 (mm)

85 Cel

GENERAL PURPOSE

-40 Cel

6.12 mm

13.16 mm

HEIGHT DIMENSION INCLUDES TERMINAL ALSO

e3

17.86 mm

1:1

TG1G-S002NZRL

Halo Electronics

DATACOM TRANSFORMER

SURFACE MOUNT

Matte Tin (Sn) - with Nickel (Ni) barrier

4

1500 V

350 uH

70 Cel

10/100 BASE-TX; ETHERNET

0 Cel

5.84 mm

12.19 mm

HEIGHT DIMENSION INCLUDES TERMINALS ALSO

e3

17.18 mm

HX5008FNLT

Pulse Electronics

DATACOM TRANSFORMER

SURFACE MOUNT

UL

Matte Tin (Sn) - with Nickel (Ni) barrier

4

1500 V

3 dB

325 uH

TAPE & REEL

Other Transformers

L17.86XB13.16XH6.12 (mm)

85 Cel

GENERAL PURPOSE

-40 Cel

6.12 mm

13.16 mm

HEIGHT DIMENSION INCLUDES TERMINAL ALSO

e3

17.86 mm

1:1

HX5014FNLT

Pulse Electronics

DATACOM TRANSFORMER

SURFACE MOUNT

Matte Tin (Sn) - with Nickel (Ni) barrier

4

1500 V

350 uH

TAPE & REEL

L27.81XB14.99XH7.24 (mm)

85 Cel

GENERAL PURPOSE

-40 Cel

7.24 mm

14.99 mm

HEIGHT DIMENSION INCLUDES TERMINALS ALSO

e3

27.81 mm

1:1

Pulse & Datacom Transformers

Pulse transformers and datacom transformers are two types of transformers used in electronic circuits for signal isolation and transmission.

Pulse transformers are used to transmit short-duration electrical pulses between two circuits, while providing electrical isolation between them. They are commonly used in applications such as digital communication, pulse amplifiers, and switching power supplies. Pulse transformers are typically designed to handle high voltage and high-frequency signals, and have a low turns ratio. They are also designed to minimize signal distortion and provide high signal integrity.

Datacom transformers, also known as isolation transformers, are used to provide electrical isolation and impedance matching between two circuits in data communication applications, such as Ethernet and other networking protocols. They are used to eliminate ground loops, reduce electromagnetic interference (EMI), and provide surge protection. Datacom transformers are typically designed to handle low voltage and low-frequency signals, and have a high turns ratio. They are also designed to provide high common-mode rejection and low insertion loss.