TIN COPPER Pulse & Datacom Transformers 3

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Impedance (Primary) Power Rating No. of Functions Impedance (Secondary) No. of Winding (Primary) Maximum Pulse Rise Time Isolation Voltage Insertion Loss Inductance (Primary) Packing Method Output Current-1 Minimum ET Product Output Current-2 Maximum DC Unbalance Current No. of Winding (Secondary) Sub-Category Dimensions Maximum Operating Temperature Application Output Voltage-1 Minimum Operating Temperature Height Width Nominal Input Voltage (V) Load Resistance Additional Features Minimum Input Voltage (V) JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency Maximum Input Voltage (V)

S558-5999-U7-F

Bel Fuse

DATACOM TRANSFORMER

SURFACE MOUNT

TIN COPPER

1

2

1500 V

1 dB

350 uH

22

Other Transformers

L12.32XB7.24XH5.72 (mm)

85 Cel

LAN; 10/100 BASE-T

-40 Cel

5.72 mm

7.24 mm

1.1 ohm

HEIGHT DIM. INCLUDE TERMINAL ALSO

e2

12.32 mm

1CT:1CT; 1CT:1CT

S558-5999-P3-F

Bel Fuse

DATACOM TRANSFORMER

SURFACE MOUNT

TIN COPPER

4

350 uH

L17.53XB12.19XH5.71 (mm)

70 Cel

ETHERNET

0 Cel

5.71 mm

12.19 mm

HEIGHT DIMENSION INCLUDES TERMINAL ALSO

e2

17.53 mm

1CT:1CT

749010013

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

UL; CSA

TIN COPPER

1

2

1500 V

1.1 dB

350 uH

TAPE & REEL

22

L12.95XBW7.11XH5.23 (mm)

85 Cel

GENERAL PURPOSE

-40 Cel

5.23 mm

7.11 mm

e2

500 KHz

12.95 mm

1:1; 1:1

100000 KHz

Pulse & Datacom Transformers

Pulse transformers and datacom transformers are two types of transformers used in electronic circuits for signal isolation and transmission.

Pulse transformers are used to transmit short-duration electrical pulses between two circuits, while providing electrical isolation between them. They are commonly used in applications such as digital communication, pulse amplifiers, and switching power supplies. Pulse transformers are typically designed to handle high voltage and high-frequency signals, and have a low turns ratio. They are also designed to minimize signal distortion and provide high signal integrity.

Datacom transformers, also known as isolation transformers, are used to provide electrical isolation and impedance matching between two circuits in data communication applications, such as Ethernet and other networking protocols. They are used to eliminate ground loops, reduce electromagnetic interference (EMI), and provide surge protection. Datacom transformers are typically designed to handle low voltage and low-frequency signals, and have a high turns ratio. They are also designed to provide high common-mode rejection and low insertion loss.