TIN OVER NICKEL Pulse & Datacom Transformers 10

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Impedance (Primary) Power Rating No. of Functions Impedance (Secondary) No. of Winding (Primary) Maximum Pulse Rise Time Isolation Voltage Insertion Loss Inductance (Primary) Packing Method Output Current-1 Minimum ET Product Output Current-2 Maximum DC Unbalance Current No. of Winding (Secondary) Sub-Category Dimensions Maximum Operating Temperature Application Output Voltage-1 Minimum Operating Temperature Height Width Nominal Input Voltage (V) Load Resistance Additional Features Minimum Input Voltage (V) JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency Maximum Input Voltage (V)

749013021

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

749013021

UL

TIN OVER NICKEL

1

1500 V

1.2 dB

350 uH

TAPE & REEL

13.64mm X 11.94mm X 6.22mm

70 Cel

LAN; 100 BASE-T

0 Cel

6.22 mm

11.94 mm

PHYSICAL DIMENSION INCLUDES HIGHT TERMINAL ALSO

e3

13.64 mm

1:1; 1:1

7490100110A

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

UL

TIN OVER NICKEL

1

1500 V

1.1 dB

350 uH

TR

Other Transformers

12.7mm x 8.8mm x 6.35mm

70 Cel

10/100 BASE-T

0 Cel

6.35 mm

8.8 mm

e3

12.7 mm

1:1

749020011A

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

UL

TIN OVER NICKEL

1

1500 V

1 dB

350 uH

TAPE & REEL

Other Transformers

L17.5XB14.2XH6.0 (mm)

85 Cel

1000 BASE-T; LAN

-40 Cel

6 mm

14.2 mm

HEIGHT DIMENSION INCLUDES TERMINAL ALSO

e3

17.5 mm

1:1; 1:1

749020023

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

UL

TIN OVER NICKEL

4

1500 V

1 dB

350 uH

TAPE & REEL

L15.11XB7.1XH4.00 (mm)

85 Cel

LAN; 1000 BASE-T

-40 Cel

4 mm

7.1 mm

HEIGHT DIMENSION INCLUDES TERMINALS ALSO

e3

15.11 mm

1:1; 1:1

7490220120

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

TIN OVER NICKEL

4

1500 V

350 uH

TR, 13 INCH

105 Cel

1000 BASE-T

-40 Cel

6.15 mm

14.7 mm

HEIGHT DIM INCLUDE TERMINAL ALSO

e3

18.29 mm

1CT:1CT; 1CT:1CT

749022011

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

749022011

TIN OVER NICKEL

1

1500 V

1 dB

350 uH

TAPE & REEL

L18.3XB12.2XH6.35 (mm)

85 Cel

LAN

-40 Cel

6.35 mm

12.2 mm

HEIGHT DIMENSION INCLUDES TERMINAL ALSO

e3

18.3 mm

1CT:1CT

749023113C

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

UL

TIN OVER NICKEL

4

1500 V

350 uH

TR, 13 INCH

85 Cel

1000 BASE-T

-40 Cel

2.4 mm

9.6 mm

HEGHT DIM INCLUDES TERMINAL ALSO

e3

16.5 mm

1:1; 1:1

SM13072APEL

Bourns

DATACOM TRANSFORMER

SURFACE MOUNT

AEC-Q200

TIN OVER NICKEL

1

1500 V

350 uH

TR, 13 INCH

L12.8XB6.9XH5.65 (mm)

125 Cel

10/100 BASE-T; ETHERNET; LAN

-40 Cel

5.65 mm

6.9 mm

HEIGHT DIMENSION INCLUDES TERMINALS ALSO

e3

12.8 mm

1:1; 1:1

PT61018AAPEL-S

Bourns

DATACOM TRANSFORMER

SURFACE MOUNT

TIN OVER NICKEL

1

1500 V

350 uH

TR, 13 INCH

85 Cel

10/100 BASE-T

-40 Cel

5.65 mm

6.9 mm

e3

12.8 mm

1CT:1CT

SM91074AL-E

Bourns

DATACOM TRANSFORMER

SURFACE MOUNT

AEC-Q200

TIN OVER NICKEL

1

1500 V

350 uH

TR, 13 INCH

125 Cel

10/100 BASE-T

-40 Cel

5.65 mm

6.9 mm

e3

12.8 mm

1:1

Pulse & Datacom Transformers

Pulse transformers and datacom transformers are two types of transformers used in electronic circuits for signal isolation and transmission.

Pulse transformers are used to transmit short-duration electrical pulses between two circuits, while providing electrical isolation between them. They are commonly used in applications such as digital communication, pulse amplifiers, and switching power supplies. Pulse transformers are typically designed to handle high voltage and high-frequency signals, and have a low turns ratio. They are also designed to minimize signal distortion and provide high signal integrity.

Datacom transformers, also known as isolation transformers, are used to provide electrical isolation and impedance matching between two circuits in data communication applications, such as Ethernet and other networking protocols. They are used to eliminate ground loops, reduce electromagnetic interference (EMI), and provide surge protection. Datacom transformers are typically designed to handle low voltage and low-frequency signals, and have a high turns ratio. They are also designed to provide high common-mode rejection and low insertion loss.