TIN SILVER Pulse & Datacom Transformers 11

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Impedance (Primary) Power Rating No. of Functions Impedance (Secondary) No. of Winding (Primary) Maximum Pulse Rise Time Isolation Voltage Insertion Loss Inductance (Primary) Packing Method Output Current-1 Minimum ET Product Output Current-2 Maximum DC Unbalance Current No. of Winding (Secondary) Sub-Category Dimensions Maximum Operating Temperature Application Output Voltage-1 Minimum Operating Temperature Height Width Nominal Input Voltage (V) Load Resistance Additional Features Minimum Input Voltage (V) JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency Maximum Input Voltage (V)

750311771

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

750311771

TIN SILVER

1

2000 V

400 uH

TAPE & REEL

L32.31XB27.03XH13.69 (mm)

125 Cel

GENERAL PURPOSE

-40 Cel

13.69 mm

27.03 mm

LENGTH DIM INCLUDES TERMINALS ALSO

e2

32.31 mm

6:1

750311591

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

750311591

TIN SILVER

1

1500 V

8 uH

TAPE & REEL

3 A

20000 mA

Other Transformers

L32.31XB27.03XH13.69 (mm)

125 Cel

GENERAL PURPOSE

15 V

-40 Cel

13.69 mm

27.03 mm

LENGTH DIM INCLUDES TERMINALS ALSO

20

e2

32.31 mm

1.5:1

48

750311625

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

750311625

TIN SILVER

1

2

1500 V

9 uH

TAPE & REEL

4 A

8000 mA

1

Other Transformers

L17.75XB13.46XH12.7 (mm)

125 Cel

GENERAL PURPOSE

3.3 V

-40 Cel

12.7 mm

13.46 mm

.006 ohm

LENGTH DIM INCLUDES TERMINALS ALSO

10

e2

17.75 mm

4:1

100 KHz

40

750311592

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

750311592

TIN SILVER

1

1500 V

8 uH

TAPE & REEL

1.9 A

18000 mA

Other Transformers

L32.31XB27.03XH13.69 (mm)

85 Cel

GENERAL PURPOSE

24 V

-40 Cel

13.69 mm

27.03 mm

LENGTH DIM INCLUDES TERMINALS ALSO

20

e2

32.31 mm

1:1

48

749012011

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

749012011

TIN SILVER

1

1500 V

1 dB

350 uH

17.1mm X 14.75mm X 8.4mm

70 Cel

10/100 BASE-T

0 Cel

8.4 mm

14.75 mm

HEIGHT DIMENSION INCLUDES TERMINALS ALSO

e2

17.1 mm

1:1; 1:1

750311783

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

TIN SILVER

1

1500 V

20 uH

TAPE & REEL

2.5 A

16000 mA

L32.31XB27.03XH13.69 (mm)

125 Cel

GENERAL PURPOSE

24 V

-40 Cel

13.69 mm

27.03 mm

LENGTH DIM INCLUDES TERMINALS ALSO

19

e2

32.31 mm

1.5:1

70

750871013

Wurth Elektronik

DATACOM TRANSFORMER

THROUGH HOLE MOUNTED

TIN SILVER

1

2

4500 V

4500 uH

TRAY

.6 A

350 mA

1

Other Transformers

L19.69XB13.72XH10.16 (mm)

125 Cel

GENERAL PURPOSE

5 V

-40 Cel

10.16 mm

13.72 mm

.048 ohm

115

e2

19.69 mm

17:1

390

7490100111

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

7490100111

TIN SILVER

2

1500 V

350 uH

L12.95XB7.11XH5.33 (mm)

105 Cel

GENERAL PURPOSE

-40 Cel

5.33 mm

7.11 mm

HEIGHT DIMENSION INCLUDES TERMINALS ALSO

e2

12.95 mm

1CT:1CT; 1CT:1CT

750871010

Wurth Elektronik

DATACOM TRANSFORMER

THROUGH HOLE MOUNTED

TIN SILVER

1

4000 V

3300 uH

TRAY

L24.0XB20.0XH16.0 (mm)

125 Cel

GENERAL PURPOSE

-40 Cel

16 mm

20 mm

e2

24 mm

14.36:1

750311675

Wurth Elektronik

DATACOM TRANSFORMER

SURFACE MOUNT

TIN SILVER

1

2

1500 V

25 uH

TAPE & REEL

2 A

2500 mA

1

Other Transformers

L15.24XB13.34XH11.43 (mm)

125 Cel

GENERAL PURPOSE

5 V

-40 Cel

11.43 mm

13.34 mm

.011 ohm

LENGTH DIM INCLUDES TERMINALS ALSO

9

e2

15.24 mm

3:1

30

CV9052-ALC

Coilcraft

PULSE TRANSFORMER

SURFACE MOUNT

TIN SILVER

1

1500 V

931.5 uH

TR, EMBOSSED PLASTIC, 7 INCH

20 V-us

85 Cel

GATE DRIVE

-40 Cel

3.05 mm

10.16 mm

LENGTH & HEIGHT DIM INCLUDES TERMINAL ALSO

e2

10.92 mm

1.25:1

Pulse & Datacom Transformers

Pulse transformers and datacom transformers are two types of transformers used in electronic circuits for signal isolation and transmission.

Pulse transformers are used to transmit short-duration electrical pulses between two circuits, while providing electrical isolation between them. They are commonly used in applications such as digital communication, pulse amplifiers, and switching power supplies. Pulse transformers are typically designed to handle high voltage and high-frequency signals, and have a low turns ratio. They are also designed to minimize signal distortion and provide high signal integrity.

Datacom transformers, also known as isolation transformers, are used to provide electrical isolation and impedance matching between two circuits in data communication applications, such as Ethernet and other networking protocols. They are used to eliminate ground loops, reduce electromagnetic interference (EMI), and provide surge protection. Datacom transformers are typically designed to handle low voltage and low-frequency signals, and have a high turns ratio. They are also designed to provide high common-mode rejection and low insertion loss.