Vicor - DCM3414V50M26C2M01

DCM3414V50M26C2M01 by Vicor

Image shown is a representation only.

Manufacturer Vicor
Manufacturer's Part Number DCM3414V50M26C2M01
Description DC-DC REGULATED POWER SUPPLY MODULE; Temperature Grade: INDUSTRIAL; No. of Terminals: 9; Package Code: XMA; Package Shape: RECTANGULAR; Surface Mount: NO;
Datasheet DCM3414V50M26C2M01 Datasheet
NAME DESCRIPTION
Package Body Material: UNSPECIFIED
Nominal Output Voltage: 24 V
Trim or Adjustable Output (V): YES
Protection(s): OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE; THERMAL
Width (mm): 35.5 mm
Maximum Output Current: 13.33 A
Maximum Total Power Output: 320 W
Surface Mount: NO
Terminal Finish: Nickel/Palladium/Gold (Ni/Pd/Au)
No. of Outputs: 1
No. of Terminals: 9
Terminal Position: UNSPECIFIED
Package Style (Meter): MICROELECTRONIC ASSEMBLY
Maximum Load Regulation: .5 %
Technology: HYBRID
JESD-30 Code: R-XXMA-X9
Package Shape: RECTANGULAR
Terminal Form: UNSPECIFIED
Maximum Operating Temperature: 100 Cel
Package Code: XMA
Minimum Output Voltage: 14.4 V
Nominal Supply Voltage (Vsup): 3.3 V
Minimum Input Voltage: 16 V
Warm-Up Time: .3 Seconds
Maximum Input Voltage: 50 V
Maximum Output Voltage: 26.4 V
Approvals (V): CE, CTUVUS,CURUS,EN,UL
JESD-609 Code: e4
Minimum Operating Temperature: -55 Cel
No. of Functions: 1
Package Equivalence Code: MODULE,9LEAD,3.38
Nominal Input Voltage: 28 V
Other IC type: DC-DC REGULATED POWER SUPPLY MODULE
Length: 85.93 mm
Main Out Ripple Voltage: .07 Vrms
Additional Features: SEATED HT-CALCULATED
Main Output Efficiency: 91.4 %
Temperature Grade: INDUSTRIAL