Thermal Magnetic Circuit Breaker Circuit Breaker 1,670

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

SU202M-K20

Abb

Thermal Magnetic Circuit Breaker

0916608

Phoenix Contact

Thermal Magnetic Circuit Breaker

3RV2011-1BA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2721-4BD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

5SY4201-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

1 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

2

A9F07425

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

GV2ME146

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

10 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.091 in (78.5 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

M9F23203

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

M9F43308

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

S203-B6

Abb

Thermal Magnetic Circuit Breaker

SU201M-K25

Abb

Thermal Magnetic Circuit Breaker

DC2DU15L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

15 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

FAZ-C5/1-NA-L

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

5 A

Snap On

10 kA

Toggle

Manual On/Off

1

FAZ-D10/2-RT

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

4.134 in (105 mm)

1.39 in (35.3 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

2

75 °C (167 °F)

GV2ME05

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

1 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm)

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

GV2ME143

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

10 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.976 in (101 mm)

1.772 in (45 mm)

IK04; IP20

3.079 x 1.772 x 3.976 in (78.2 x 45 x 101 mm)

Trip

3.091 in (78.5 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

GV2ME14AE11TQ

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

10 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.504 in (89 mm)

1.752 in (44.5 mm)

IK04; IP20

Trip

3.079 in (78.2 mm)

EN; IEC

3

60 °C (140 °F)

GV2ME14TQ

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

M9F43108

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

SU202M-C10

Abb

Thermal Magnetic Circuit Breaker

1SDA068058R1

Abb

Thermal Magnetic Circuit Breaker

3RV2011-1HA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

450 V

8 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.78 in (97 x 45 x 96 mm)

Trip

3.78 in (96 mm)

3

60 °C (140 °F)

410218

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

50 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

3.154 in (80.1 mm)

Manual On/Off

3.11 in (79 mm)

IEC

3

70 °C (158 °F)

FAZ-C40/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

40 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

3

75 °C (167 °F)

Short

GV2ME06

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

1.6 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

LV429843

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

M9F43220

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

1C6UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

6 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

4.146 in (105.3 mm)

0.689 in (17.5 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

1

55 °C (131 °F)

2CCP814001R1849

Abb

Thermal Magnetic Circuit Breaker

2CCP814001R1849

2DU5L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

5SY4202-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

2 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

2

FAZ-C6/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

6 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

2.362 in (60 mm)

CCC; CSA; UL; VDE

3

75 °C (167 °F)

Short

M9F43208

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

S201-D20NA

Abb

Thermal Magnetic Circuit Breaker

2C5UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

2CU5L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

FAZ-C32/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

32 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

3

75 °C (167 °F)

Short

GV3P501

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

GV3P506

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

50 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Reference standard: UL

Rotary Handle

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09; IP20

Trip

5.354 in (136 mm)

ABS; ATEX; BV; CSA; CCC; DNV-GL; EAC; EN; IEC; LR0S; UKCA

3

60 °C (140 °F)

M9F43203

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

MG24519

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

4 A

Snap On

-30 °C (-22 °F)

5 kA

Toggle

Bulk

3.189 in (81 mm)

1.417 in (36 mm)

IP20; IP40

Trip

2.874 in (73 mm)

CCC; CSA; IEC; UL

2

70 °C (158 °F)

S204M-B10

Abb

Thermal Magnetic Circuit Breaker

SU201M-Z13

Abb

Thermal Magnetic Circuit Breaker

0916604

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

28 V

1 A

Screw

-30 °C (-22 °F)

3.524 in (89.5 mm)

0.484 in (12.3 mm)

IP20; IP40

3.524 x 0.484 x 3.366 in (89.5 x 12.3 x 85.5 mm)

3.366 in (85.5 mm)

CSA; CUL; EN; UL; VDE

1

60 °C (140 °F)

18644

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

3C1UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

3RV1021-1EA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

4 A

Screw And Snap On

6 kA

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.78 in (97 x 45 x 96 mm)

Trip

3.78 in (96 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

3RV2011-1FA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

Instantaneous

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.