Thermal Magnetic Circuit Breaker Circuit Breaker 1,670

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

3RV2021-4BA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Snap On

-20 °C (-4 °F)

2 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2341-4JC10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

63 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Rotary Handle

6.496 in (165 mm)

2.756 in (70 mm)

IP00; IP20

6.496 x 2.756 x 6.929 in (165 x 70 x 176 mm)

Trip

6.929 in (176 mm)

3

60 °C (140 °F)

410202

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

25 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

2.102 in (53.4 mm)

Manual On/Off

3.11 in (79 mm)

IEC

2

70 °C (158 °F)

422191

Legrand

Thermal Magnetic Circuit Breaker

Panel Mount

400 V

250 A

Screw

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

10.236 in (260 mm)

7.205 in (183 mm)

Trip

5.669 in (144 mm)

IEC

4

70 °C (158 °F)

5SY4110-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

10 A

Snap On

-25 °C (-13 °F)

5 kA

Handle

3.543 in (90 mm)

0.709 in (18 mm)

3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm)

Trip

2.992 in (76 mm)

CE; CSA; EN; UL

1

45 °C (113 °F)

5SY4363-6

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

63 A

Snap On

10 kA

3.535 in (89.8 mm)

2.079 in (52.8 mm)

IP20

3.535 x 2.079 x 2.992 in (89.8 x 52.8 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

3

9124243200

Weidmueller & Kg

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

80 V

200 mA

Snap On

-30 °C (-22 °F)

200 A

Rated breaking capacity at 65 VDC: 200 A

Push To Reset

3.15 in (80 mm)

0.984 in (25 mm)

Corrosion Resistant; Moisture Resistant

3.15 x 0.984 x 2.087 in (80 x 25 x 53 mm)

Trip

2.087 in (53 mm)

CSA; UL; VDE

2

55 °C (131 °F)

915031

Phoenix Contact

Thermal Magnetic Circuit Breaker

915031

A9F79106

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

A9N18392

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

500 V

100 A

Snap On

-25 °C (-13 °F)

6 kA

Rated breaking capacity at 500 VDC: 10000 A

Toggle Handle

Bulk

4.252 in (108 mm)

3.189 in (81 mm)

IP20

Trip

2.874 in (73 mm)

EN; IEC

4

70 °C (158 °F)

DC2CU15L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

15 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

DC2DU25L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

EGE3040FFG

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

347 V

40 A

Screw

18 kA

Toggle Handle

5.5 in (139.7 mm)

3 in (76.2 mm)

Manual On/Off

2.992 in (76 mm)

CE; CSA; IEC; UL

3

EGE3050FFG

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

347 V

50 A

Screw

18 kA

Toggle Handle

5.5 in (139.7 mm)

3 in (76.2 mm)

Manual On/Off

2.992 in (76 mm)

CE; CSA; IEC; UL

3

EGE3070FFG

Eaton Corporation

Thermal Magnetic Circuit Breaker

Panel Mount

347 V

70 A

Screw

18 kA

Toggle Handle

5.5 in (139.7 mm)

3 in (76.2 mm)

Manual On/Off

2.992 in (76 mm)

CE; CSA; IEC; UL

3

FAZ-C1.5/2-NA-L

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

1.5 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C10/2-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

10 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C15/2-NA-L

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

15 A

Snap On

10 kA

Toggle

Manual On/Off

2

FAZ-C15/3-RT

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

15 A

Snap On

-25 °C (-13 °F)

14 kA

Toggle

4.134 in (105 mm)

2.091 in (53.1 mm)

Trip Free

1.772 in (45 mm)

CSA; UL

3

75 °C (167 °F)

FAZ-C20/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

20 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

2.362 in (60 mm)

CCC; CSA; UL; VDE

3

75 °C (167 °F)

Short

FAZ-C3/3

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

96 V

3 A

Snap On

-40 °C (-40 °F)

15 kA

Toggle

3.15 in (80 mm)

2.091 in (53.1 mm)

IP20

Manual On/Off

2.362 in (60 mm)

CCC; CE; CSA; IEC; UL; VDE

3

75 °C (167 °F)

Short

FAZ-C5/1-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

5 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

FAZ-D20/3-NA

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

60 V

20 A

Snap On

-25 °C (-13 °F)

15 kA

Manual On/Off

4.134 in (105 mm)

2.091 in (53.1 mm)

IP20; IP40

Trip

2.972 in (75.5 mm)

CSA; EN; IEC; UL

3

75 °C (167 °F)

GB2CD09

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

GV2ME053

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

1 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Push Button

Bulk

3.976 in (101 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

GV2ME056

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

GV2ME05TQ

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

GV2ME163

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

14 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.976 in (101 mm)

1.772 in (45 mm)

IK04; IP20

3.976 x 1.752 x 2.646 in (101 x 44.5 x 67.2 mm)

Trip

3.091 in (78.5 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

GV2ME20

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

18 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm)

Trip

3.091 in (78.5 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

GV3P25

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

25 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Reference standard: UL

Rotary Handle

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09; IP20

Trip

5.354 in (136 mm)

ABS; ATEX; BV; CSA; CCC; DNV-GL; EAC; EN; IEC; LR0S; UKCA

3

60 °C (140 °F)

GV3P40

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

40 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Reference standard: UL

Rotary Handle

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09; IP20

Trip

5.354 in (136 mm)

ABS; ATEX; BV; CSA; CCC; DNV-GL; EAC; EN; IEC; LR0S; UKCA

3

60 °C (140 °F)

GV3P401

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

40 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Rotary Handle

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09

Trip

5.354 in (136 mm)

CSA; EN; IEC; UL

3

60 °C (140 °F)

M9F22170

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

M9F23104

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

M9F23201

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

M9F42110

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

415 V

60 V

10 A

Snap On

-30 °C (-22 °F)

3 kA

Toggle

Bulk

4.055 in (103 mm)

0.709 in (18 mm)

IP20; IP40

Trip

2.835 in (72 mm)

CCC; CSA; EN; GB; IEC; UL

1

70 °C (158 °F)

M9F43305

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

PKZM0-25

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

25 A

Snap On

-25 °C (-13 °F)

50 kA

Rated breaking capacity max at: 400 VAC

Button

3.638 in (92.4 mm)

1.772 in (45 mm)

IP00; IP20

Trip

2.65 in (67.3 mm)

CE; CSA; IEC/EN; UL

3

55 °C (131 °F)

S202-C63

Abb

Thermal Magnetic Circuit Breaker

S204-D63

Abb

Thermal Magnetic Circuit Breaker

SU201M-K13

Abb

Thermal Magnetic Circuit Breaker

SU202M-C15

Abb

Thermal Magnetic Circuit Breaker

SU202M-C40

Abb

Thermal Magnetic Circuit Breaker

140M-C2E-B25

Rockwell Automation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

600 V

600 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Manual On/Off

3.622 in (92 mm)

1.772 in (45 mm)

Moisture Resistant; IP2X

Shunt Trip

2.618 in (66.5 mm)

CCC; CE; CSA; CUL; EN; IEC; UL

3

60 °C (140 °F)

Instantaneous

2210-T210-K0M1-H121-10A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

Panel Mount

250 V

65 V

10 A

Screw

-30 °C (-22 °F)

800 A

Rated breaking capacity at 32 VDC: 2500 A

Toggle

1.772 in (45 mm)

0.492 in (12.5 mm)

1.772 x 0.492 x 0.122 in (45 x 12.5 x 3.09 mm)

Manual On/Off

0.122 in (3.09 mm)

CSA; GL; UL; VDE

1

60 °C (140 °F)

2C2UM

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

80 V

2 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

Handle

Bulk

3.516 in (89.3 mm)

1.378 in (35 mm)

IP20

Under Voltage Release

2.693 in (68.4 mm)

CSA; UL; VDE

2

55 °C (131 °F)

2CDS251103R0204

Abb

Thermal Magnetic Circuit Breaker

2CDS271001R0024

Abb

Thermal Magnetic Circuit Breaker

2CDS271001R0024

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.