Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Defense Logistics Agency |
Thermal Circuit Breaker |
Panel Mount |
120 V |
28 V |
10 A |
Screw |
-55 °C (-67 °F) |
2.5 kA |
Rated breaking capacity at 28 VDC: 6000 A |
Push-Pull |
0.781 in (19.84 mm) |
0.593 in (15.06 mm) |
Corrosion Resistant; Moisture Resistant |
0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm) |
Trip Free |
1.03 in (26.16 mm) |
MIL-C-5809 |
1 |
121 °C (249.8 °F) |
||||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
10 A |
Stud |
5 kA |
Toggle |
5.125 in (130.18 mm) |
1.026 in (26.06 mm) |
Moisture Resistant |
Trip Free |
3.55 in (90.17 mm) |
CSA; CUL; UL |
1 |
|||||||||||||
Texas Instruments |
Thermal Circuit Breaker |
Panel Mount |
120 V |
28 V |
10 A |
Screw |
2.5 kA |
2TC2 |
Push-Pull |
0.781 in (19.84 mm) |
0.593 in (15.06 mm) |
Corrosion Resistant |
0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm) |
1.03 in (26.16 mm) |
|||||||||||||
Abb |
Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
500 V |
10 A |
Snap On |
-25 °C (-13 °F) |
6 kA |
Toggle Handle |
Bulk |
3.465 in (88 mm) |
1.378 in (35 mm) |
IP20; IP40 |
Trip |
2.717 in (69 mm) |
CSA; UL; VDE |
2 |
55 °C (131 °F) |
|||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
12 V |
10 A |
Quick Connect |
-40 °C (-40 °F) |
150 A |
Reset Button |
0.524 in (13.3 mm) |
0.276 in (7 mm) |
Corrosion Resistant; IP00; IP40 |
Trip |
0.984 in (25 mm) |
1 |
85 °C (185 °F) |
|||||||||||
|
Abb |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
125 V |
10 A |
Screw |
-25 °C (-13 °F) |
6 kA |
IP40 in enclosure with cover |
Toggle Handle |
Bulk |
3.465 in (88 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.717 in (69 mm) |
CSA, EN/IEC, UL |
2 |
55 °C (131 °F) |
|||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
1 kA |
2.2 s |
Push To Reset |
0.625 in (15.88 mm) |
0.54 in (13.72 mm) |
0.625 x 0.54 x 1.535 in (15.88 x 13.72 x 38.99 mm) |
Series Trip |
1.535 in (38.99 mm) |
CSA; UL; VDE |
1 |
||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
2.2 s |
Push To Reset |
Series Trip |
1 |
|||||||||||||||||
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
2.2 s |
Push To Reset |
Series Trip |
1 |
|||||||||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
10 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
1.515 in (38.48 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
|||||||||
|
Abb |
Thermal Circuit Breaker |
DIN Rail Mount |
690 V |
10 A |
Screw |
-25 °C (-13 °F) |
18 kA |
Rotary Handle |
Bulk |
3.85 in (97.8 mm) |
1.772 in (45 mm) |
IP10; IP20 |
Trip Free |
3.388 in (86.05 mm) |
EN; IEC |
3 |
70 °C (158 °F) |
|||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
10 A |
Screw |
1 kA |
6 s |
Toggle |
1.384 in (35.15 mm) |
0.69 in (17.53 mm) |
Corrosion/Environment/Moisture Resistant |
Series Trip |
1.6 in (40.64 mm) |
CSA; UL |
1 |
||||||||||
|
Siemens |
Thermal Circuit Breaker |
DIN Rail Mount |
400 V |
10 A |
Snap On |
-25 °C (-13 °F) |
5 kA |
5SY4110-7 |
Environmental Characteristics: IP20; Sealed |
3.535 in (89.8 mm) |
0.693 in (17.6 mm) |
Environment/Moisture Resistant |
3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm) |
Trip |
2.764 in (70.2 mm) |
CE; EAC; IMQ; KTL; UL; VDE |
1 |
55 °C (131 °F) |
||||||||
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
12 V |
10 A |
Quick Connect |
-40 °C (-40 °F) |
150 A |
Modified Reset |
0.524 in (13.3 mm) |
0.276 in (7 mm) |
Corrosion Resistant; IP00; IP50 |
Trip |
0.984 in (25 mm) |
1 |
85 °C (185 °F) |
||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
120 V |
28 V |
10 A |
Screw |
-55 °C (-67 °F) |
3.5 kA |
Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A |
Push Button |
0.781 in (19.84 mm) |
0.593 in (15.06 mm) |
Corrosion Resistant; Moisture Resistant |
0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm) |
Trip |
1.03 in (26.16 mm) |
1 |
121 °C (249.8 °F) |
|||||||||
|
Abb |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
48 V |
10 A |
Screw And Snap On |
-25 °C (-13 °F) |
10 kA |
200 ms |
Bulk |
4.37 in (111 mm) |
0.689 in (17.5 mm) |
IP20; IP40 |
Shunt Trip |
2.717 in (69 mm) |
CCC; CSA; EN; IEC; UL; VDE |
1 |
55 °C (131 °F) |
Instantaneous |
|||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
10 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
Corrosion/Moisture Resistant; IP00; IP40 |
Manual On/Off |
CCC; CE; CSA; CQC; KTL; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
10 A |
Screw And Snap On |
-20 °C (-4 °F) |
6 kA |
Rotary Handle |
Bulk |
3.504 in (89 mm) |
1.772 in (45 mm) |
IK04; IP20 |
Trip |
3.819 in (97 mm) |
ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL |
3 |
60 °C (140 °F) |
|||||||||
Sensata Technologies |
Thermal Circuit Breaker |
Panel Mount |
120 V |
30 V |
10 A |
Screw |
3.5 kA |
1 s |
Rated breaking capacity at 30 VDC: 6000 A |
Push-Pull |
1.094 in (27.79 mm) |
0.75 in (19.05 mm) |
Corrosion/Moisture Resistant |
1.094 x 0.75 x 1.49 in (27.79 x 19.05 x 37.85 mm) |
Trip Free |
1.49 in (37.85 mm) |
1 |
||||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
240 V |
48 V |
10 A |
Quick Connect |
-5 °C (23 °F) |
Tin Silver |
2 kA |
Reset Type |
Bulk |
0.748 in (19 mm) |
0.748 in (19 mm) |
IP40 |
e2 |
Manual On/Off |
1.421 in (36.1 mm) |
CCC; CSA; UL; GB; IEC; UL; VDE |
1 |
60 °C (140 °F) |
||||||
|
Abb |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
96 V |
10 A |
Screw And Snap On |
-25 °C (-13 °F) |
10 kA |
200 ms |
Bulk |
4.37 in (111 mm) |
1.378 in (35 mm) |
IP20; IP40 |
Shunt Trip |
2.717 in (69 mm) |
CCC; CSA; EN; IEC; UL; VDE |
2 |
55 °C (131 °F) |
Instantaneous |
|||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
10 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Rocker |
2.156 in (54.76 mm) |
0.745 in (18.92 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
Defense Logistics Agency |
Thermal Circuit Breaker |
Panel Mount-Threaded |
10 A |
Screw |
-55 °C (-67 °F) |
Push-Pull |
1.84 in (46.74 mm) |
0.781 in (19.84 mm) |
1.84 x 0.781 x 1.381 in (46.74 x 19.84 x 35.08 mm) |
Trip Free |
1.381 in (35.08 mm) |
MIL-C-5809 |
3 |
71 °C (159.8 °F) |
|||||||||||||
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
10 A |
Snap On |
-20 °C (-4 °F) |
4 kA |
Interrupting current max at 450 VDC: 10000 A |
Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm) |
Trip |
3.815 in (96.9 mm) |
ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE |
3 |
60 °C (140 °F) |
Instantaneous |
|||||||
Sensata Technologies |
Magnetic Circuit Breaker |
Panel Mount |
240 V |
50 V |
10 A |
Wire/Solder |
-40 °C (-40 °F) |
1 kA |
Rated breaking capacity at 50 VDC: 2000 A |
Toggle Lever |
2.53 in (64.26 mm) |
0.78 in (19.81 mm) |
Unsealed |
2.53 x 0.78 x 2.8 in (64.26 x 19.81 x 71.12 mm) |
Trip Free |
2.8 in (71.12 mm) |
MIL-PRF-55629/2 |
1 |
85 °C (185 °F) |
Instantaneous |
|||||||
|
Siemens |
Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
10 A |
Screw And Snap On |
-20 °C (-4 °F) |
4 kA |
Rotary Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
400 V |
10 A |
Snap On |
10 kA |
3.535 in (89.8 mm) |
1.386 in (35.2 mm) |
IP20 |
3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm) |
Trip |
2.992 in (76 mm) |
CCC; CE; IMQ; RCM; UL; VDE |
2 |
||||||||||||
Eaton Corporation |
Thermal Circuit Breaker |
Panel Mount |
120 V |
28 V |
10 A |
Screw |
-55 °C (-67 °F) |
3.5 kA |
Standard: MIL-C-5809, rated breaking capacity at 28 VDC: 6000 A |
Push Button |
0.781 in (19.84 mm) |
0.593 in (15.06 mm) |
Corrosion Resistant; Moisture Resistant |
0.781 x 0.593 x 1.03 in (19.84 x 15.06 x 26.16 mm) |
Trip |
1.03 in (26.16 mm) |
1 |
121 °C (249.8 °F) |
|||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
10 A |
Quick Connect |
1 kA |
3 s |
Rocker |
1.89 in (48.01 mm) |
0.98 in (24.89 mm) |
Series Trip |
1.724 in (43.79 mm) |
2 |
||||||||||||
|
Siemens |
Thermal Circuit Breaker |
DIN Rail Mount |
400 V |
10 A |
Snap On |
-25 °C (-13 °F) |
14 kA |
5SJ4110-7HG40 |
ENVIRONMENTAL CHARACTERISTICS: IP20; IP40; SEALED |
3.543 in (90 mm) |
0.709 in (18 mm) |
Environment/Moisture Resistant |
3.543 x 0.709 x 2.756 in (90 x 18 x 70 mm) |
Trip |
2.756 in (70 mm) |
CCC; CE; EAC; UL; VDE |
1 |
55 °C (131 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
10 A |
Screw And Snap On |
-20 °C (-4 °F) |
3 kA |
Push Button |
Bulk |
3.504 in (89 mm) |
1.772 in (45 mm) |
IK04; IP20 |
3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm) |
Trip |
3.091 in (78.5 mm) |
ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL |
3 |
60 °C (140 °F) |
||||||||
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
240 V |
60 V |
10 A |
Quick Connect |
-30 °C (-22 °F) |
2 kA |
Rocker |
Bulk |
1.417 in (36 mm) |
1.142 in (29 mm) |
IP40 |
Trip Free |
1.736 in (44.1 mm) |
CCC; CSA; GB; IEC; UL; VDE |
2 |
60 °C (140 °F) |
||||||||
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
240 V |
10 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
2 |
||||||||||||||||||
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Tab |
2.5 kA |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Series Trip |
1.693 in (43 mm) |
CE; CSA; CUL; TUV; UL |
1 |
|||||||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; CSA; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
10 A |
Screw |
-40 °C (-40 °F) |
7.5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Toggle |
2 in (50.8 mm) |
0.74 in (18.8 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.817 in (46.15 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
10 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
3 |
Instantaneous |
||||||||||||||||
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
10 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.146 in (105.3 mm) |
1.378 in (35 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
2 |
55 °C (131 °F) |
|||||||||||
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Tab |
2.5 kA |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Series Trip |
1.693 in (43 mm) |
CE; CSA; CUL; TUV; UL |
1 |
|||||||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
10 A |
Snap On |
10 kA |
Toggle |
Manual On/Off |
1 |
|||||||||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
10 A |
Quick Connect |
1 kA |
6 s |
Push To Reset |
1.375 in (34.93 mm) |
0.66 in (16.76 mm) |
Series Trip |
1.375 in (34.93 mm) |
1 |
||||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
10 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
2.22 in (56.4 mm) |
0.984 in (25 mm) |
Corrosion Resistant; IP00; IP40 |
Trip Free |
1.299 in (33 mm) |
CCC; CSA; KC; UL; VDE |
2 |
60 °C (140 °F) |
||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
10 A |
Screw And Snap On |
-20 °C (-4 °F) |
3 kA |
Push Button |
Bulk |
3.504 in (89 mm) |
1.772 in (45 mm) |
IK04; IP20 |
Trip |
3.091 in (78.5 mm) |
ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL |
3 |
60 °C (140 °F) |
|||||||||
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
10 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2 in (50.8 mm) |
0.75 in (19.05 mm) |
Fungus Resistant; Moisture Resistant |
2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm) |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
Standard |
|||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
10 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
2.22 in (56.4 mm) |
0.984 in (25 mm) |
Corrosion Resistant; IP00; IP40 |
Trip Free |
1.299 in (33 mm) |
CCC; CSA; KC; UL; VDE |
2 |
60 °C (140 °F) |
||||||||
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
10 A |
Quick Connect |
-10 °C (14 °F) |
300 A |
Rated breaking capacity at 32 VDC: 2500 A |
Push To Reset |
1.378 in (35 mm) |
0.571 in (14.5 mm) |
Fire Resistant |
Series Trip |
1.693 in (43 mm) |
CE; TUV; UL |
1 |
60 °C (140 °F) |
||||||||
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
10 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle |
4.134 in (105 mm) |
1.39 in (35.3 mm) |
Trip Free |
1.772 in (45 mm) |
CSA; UL |
2 |
75 °C (167 °F) |
|||||||||||
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
10 A |
Screw And Snap On |
-20 °C (-4 °F) |
3 kA |
Push Button |
Bulk |
3.976 in (101 mm) |
1.772 in (45 mm) |
IK04; IP20 |
3.079 x 1.772 x 3.976 in (78.2 x 45 x 101 mm) |
Trip |
3.091 in (78.5 mm) |
ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL |
3 |
60 °C (140 °F) |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.